Project

General

Profile

Kaon LT Meetings » mtg_23feb23.txt

Garth Huber, 02/24/2023 11:10 AM

 
1
                 Feb 23/23 PionLT/KaonLT Analysis Meeting Notes
2
                 ----------------------------------------------
3
                           (Notes by GH and SJDK)
4

    
5
                    Today: PionLT will be discussed first
6

    
7
Please remember to post your slides at:
8
https://redmine.jlab.org/projects/kltexp/wiki/Kaon_LT_Meetings
9

    
10
Present
11
-------
12
Regina - Stephen Kay, Garth Huber, Ali Usman, Alicia Postuma, Nathan Heinrich,
13
   Vijay Kumar, Love Preet, Muhammad Junaid
14
JLab - Dave Gaskell
15
Ohio - Jacob Murphy, Julie Roche
16
CUA - Tanja Horn
17

    
18
Dave G Updates (on behalf of Richard)
19
--------------
20
EM/PM calculations
21
- Met with with Richard on implementing post-SIMC script
22
   - Found a few bugs and things that needed to be adjusted
23
   - Once meeting was done, seemed to be working ok
24
   - Some distributions were looking a bit weird, but seemed to be resolved,
25
     particular for EM
26
   - don't know yet on how well the new SIMC calculations reproduce data
27

    
28
Nathan Updates
29
--------------
30
Ref/Det time cuts
31
- Tested on some settings with online analysis scripts
32
- continuing on LD- setting that got less events than online analysis
33
   - Checked cuts, all looked ok
34
   - reran online scripts with identical cuts to new analysis with exception of
35
     Ref Time
36
   - New cuts reduce # events in LD- Q2=3.85, W=2.62, low eps setting by ~20%
37

    
38
- Other settings don't see the same effect though, get more after updating
39
  ref/det time cuts
40
   - For LD- Q2=3.85, W=2.62, center, hi eps the #counts goes up slightly
41
   - For LH+ runs checked, the events also go up
42

    
43
- For LD- setting with reduction, seems uniform across all plots, see similar drop
44
  for all types of events - prompt/random
45
   - NH thinks it could be due to a PID detector calibration shift with new
46
     cuts, and the proportion of good events passing cut has gone down, would
47
     need recalibration and adjustment of cuts to be sure
48
   - SK: Should investigate quickly to see if it's a uniform reduction or one
49
     particular run/set of runs causing weird issues
50
   - Setting was in two parts, separated by several days (i.e. we came back to
51
     get more statistics after completing other parts of run plan)
52
      - GH: Should absolutely compare each part before/after applying new det/ref
53
        cuts
54
      - Split the 74 runs in this setting into batches? 
55
         - Day by day? OR Shift by shift?
56
      - need enough statistics in each batch to be able to draw conclusions
57
   - in fact, for *all* settings divided into multiple parts by time, the
58
     parts need to be looked at separately, and only combined after we are
59
     sure everything is consistent
60
      - this includes all detector calibrations, etc
61
   - *** this study can be done in parallel with detector calibrations, but
62
     *** it is essential that we understand what is going on with this LD-
63
     *** setting, as a 20% effect is huge!
64

    
65
Jacob Murphy
66
------------
67
- No elastic delta scans yet
68
   - Recovering from an illness
69
   - Working through some old hard coded scripts, getting them going for PionLT
70

    
71
Junaid Updates
72
--------------
73
- Busy with NP course
74
   - Midterm next week
75
- No report on calibrations yet
76

    
77
Ali Updates
78
-----------
79
HMS Cal/Cer Efficiency - HeeP Singles Studies to get clean sample of electrons
80

    
81
- Heep #1 Run 6600 - Ebeam=3.835, Phms=2.835 GeV/c
82
   - Cer 97.20%, Cal 99.63%
83
   - Much better Cherenkov efficiency
84
   - Calorimeter v.good
85
- Heep #2 Run 6603 - Ebeam=3.835, Phms=2.713 GeV/c
86
   - Cer 97.31%, Cal 99.64%
87
- Heep #3 Run 6608 - Ebeam=3.835, Phms=2.583 GeV/c
88
   - Cer 97.34%, Cal 99.65%
89
- Heep #4 Run 6680 - Ebeam=4.933, Phms=2.583 GeV/c
90
   - Cer 97.46%, Cal 99.47%
91
- Heep #5 Run 7852 - Ebeam=6.190, Phms=3.709 GeV/c
92
   - Cer 97.12%, Cal 99.37%
93
- Heep #6 Run 7857 - Ebeam=6.190, Phms=3.491 GeV/c
94
   - Cer 97.17%, Cal 99.29%
95

    
96
- Rate Dependence plot, eff vs rate (S1X)
97
   - Cherenkov eff seems to have a fairly slow drop off with rate
98
   - Calorimeter has no obvious trend
99
   - Not much of a spread in S1X though, ~35 kHz to 70 kHz
100

    
101
   - Physics rate range is a bit higher, up to 150-200 kHz
102

    
103
   - DG: considers this study to be ~90% complete
104
     1) would be nice to get a firmer handle on the rate dependence
105
       - are there physics data at higher rate with favorable pi-/e-?
106
     2) need to check for dip in HMS Cer efficiency where mirrors overlap
107
       - this hasn't been checked yet after the mirror replacement
108
       - 1D plot of Cher eff vs X_cer should be sufficient
109

    
110
   - Cal eff is often parameterized vs Phms, as the energy resolution changes
111
   - Cer eff is usually just a fixed number, unless there's a rate dependence,
112
     in which case this rate dependence needs to be understood
113
   - NH: a *plot* of Cal eff vs. Phms would be useful, maybe this would explain
114
     some of the outliers in the rate dependence plot
115

    
116
- Next step is to finalise PID
117
   - For coin events, pi- background will be removed with CT cuts etc
118
   - Should have a fairly clean electron sample with coincidences to find a
119
     good efficiency a higher rate
120

    
121
Vijay Updates
122
-------------
123
Phi and t binning in progress, full report next week
124
- Yield calculation per (t,phi) bin
125
   - Will have the rest next week hopefully
126

    
127
Alicia Updates
128
--------------
129
- 2nd place in best overall presentation at WNPPC (Winter Nuclear and Particle
130
  Physics Conference) in Banff, Alberta
131
   - Well done Alicia!
132
- Circulated abstract for CAP
133
   - Feedback/comments appreciated
134
- Depending upon word/character limit, maybe clarify "Transition regime" in
135
  abstract
136

    
137
Next Meeting
138
------------
139
Thur Mar 2 @ 17:00 Eastern/16:00 Regina/15:00 Mtn/14:00 Pacific
140
- KaonLT will go first
141

    
142
USA savings time starts Mar 12, so we need a poll to find a meeting time.
143
GH will circulate one soon.
144

    
145

    
146

    