1
|
May 15/25 PionLT/KaonLT Analysis Meeting Notes
|
2
|
----------------------------------------------
|
3
|
(Notes by GH)
|
4
|
|
5
|
Today: PionLT will be discussed first
|
6
|
|
7
|
Please remember to post your slides at:
|
8
|
https://redmine.jlab.org/projects/kltexp/wiki/Kaon_LT_Meetings
|
9
|
|
10
|
Present
|
11
|
-------
|
12
|
Regina - Garth Huber, Nathan Heinrich, Muhammad JUnaid, Ivan Zhenchuk,
|
13
|
Nacer Hamdi, Ali Usman, Vijay Kumar, Alicia Postuma
|
14
|
CSULA - Konrad Aniol
|
15
|
Virginia - Richard Trotta
|
16
|
|
17
|
Ali
|
18
|
---
|
19
|
piDelta MM shape study, refining high statistics settings
|
20
|
|
21
|
Q2=3.0, W=3.14 - now 3 t-bins, previously 2 t-bins
|
22
|
- new t-bins: 0-0.33, 0.33-0.42, 0.42-0.72
|
23
|
- low t center SHMS
|
24
|
- pi+n (brown line) MC has more fluctutations in Delta region than other 2
|
25
|
MC, might need to run it longer to get adequate statistics in tail
|
26
|
|
27
|
- mid t center SHMS
|
28
|
- pi+n doesn't have very many events in this region, so removed it from fit
|
29
|
- fit region is 1.11<MM<1.4 GeV
|
30
|
- mid t right SHMS
|
31
|
- pi+n is included here
|
32
|
- mid t left SHMS
|
33
|
- of 8 phi-bins, 2 are excluded due to difficult fits in Delta region
|
34
|
- 4 phi bins are empty, so this leaves just 2 phi bins with fit data:
|
35
|
-135 to -180, +130 to +180
|
36
|
- full phi coverage is obtained over 3 SHMS settings
|
37
|
|
38
|
- high t center SHMS
|
39
|
- bkd much larger here than at lower t
|
40
|
- there is data in all 8 phi bins, but 4 bins need to be excluded due to lack
|
41
|
of Delta peak
|
42
|
- high t right SHMS
|
43
|
- MM fits are done for only 2 phi bins, 0 to +45, -45 to 0
|
44
|
- 2 phi bins excluded due to unclear Delta peak
|
45
|
- 4 phi bins empty
|
46
|
- high t left SHMS
|
47
|
- can do fits for all 4 phi bins with data
|
48
|
- full phi coverage is obtained, 4+2+4 phi bins in total over 3 SHMS settings
|
49
|
|
50
|
Q2=2.1, W=2.95
|
51
|
- new t-bins: 0-0.25, 0.25-0.33, 0.33-0.60
|
52
|
- only results for highest t-bin shown
|
53
|
- high t center SHMS
|
54
|
- fit only 4 phi bins: 0 to +45, +45 to +90, -45 to 0, -90 to -45
|
55
|
- high t right SHMS
|
56
|
- fit MM data for 2 phi bins: 0 to +45, -45 to 0
|
57
|
- high t left SHMS
|
58
|
- fit MM data for 4 phi bins:
|
59
|
+90 to +135, +135 to +180, -180 to -135, -135 to -90
|
60
|
- full phi coverage is obtained, 4+2+4 phi bins in total over 3 SHMS settings
|
61
|
|
62
|
Next steps:
|
63
|
- check that all shape study plots are ok
|
64
|
- then extract asymmetry and recalculate mean kinematics per t-bin
|
65
|
- start systematic studies on MM fit dependence
|
66
|
|
67
|
Nathan
|
68
|
------
|
69
|
PionLT luminosity scans
|
70
|
- last week, noted some weird behavior in #counts surviving cuts. Looked at
|
71
|
actual numbers produced by scripts to diagnose
|
72
|
- found that scipy.integrate.* was used in scripts to integrate counts
|
73
|
- this is not a true integration, rather a function is fit to the histogram
|
74
|
and the fit is integrated. Anomalies happen if the fit is not good
|
75
|
- removed this function, now gets true #events in histogram
|
76
|
- ***NB*** EXTREMELY IMPORTANT THAT EVERYONE CHECK THEIR SCRIPTS TO MAKE
|
77
|
SURE scipy.integrate.* IS NOT USED ANYWHERE!!!
|
78
|
- possibly this could explain some of the weird behavior Richard has noted
|
79
|
in the past
|
80
|
- scaler yields are unchanged, but all histogram yields need to be rechecked
|
81
|
|
82
|
- Carbon Lumi
|
83
|
- still need to recheck if Dave Mack's combinatoric ELLT is applied to
|
84
|
scaler scans
|
85
|
- Yield-NoTrack, Yield-Track generally look good, but some new outliers
|
86
|
- investigating further
|
87
|
- overall, very similar to earlier Lumi analysis, conclusions overall valid
|
88
|
|
89
|
- LH2 Lumi
|
90
|
- some very large error bars for SHMS scalers but not HMS scalers, which
|
91
|
doesn't look right, will investigate
|
92
|
|
93
|
- Coin Lumi
|
94
|
- analysis still has a major bug, looking into it
|
95
|
|
96
|
- *NB* still looking at hodoscope time shift reported last week
|
97
|
|
98
|
Junaid
|
99
|
------
|
100
|
PionLT LT-sep analysis
|
101
|
- calculating average kinematic variables for each t-bin
|
102
|
- still need to calculate epsilon, theta* per bin
|
103
|
- the angle variable is P.kin.secondary.th_pq
|
104
|
|
105
|
- also some discussion about units:
|
106
|
- theta*,phi is in rad for data
|
107
|
- theta*,phi is in deg for SIMC (preferred)
|
108
|
- phi in SIMC goes from -180 to +180, while in hcana it goes 0 to 2pi
|
109
|
- Richard did not make these consistent in recon_hcana, but did it in his
|
110
|
analysis script
|
111
|
- *NB* a good future task would be to add this in recon_hcana so SIMC and
|
112
|
data have same units and ranges
|
113
|
|
114
|
- next step will be sig_UNS cross-section calculation from the Data/MC ratios
|
115
|
and model
|
116
|
|
117
|
Richard
|
118
|
-------
|
119
|
KaonLT LT-sep analysis
|
120
|
- Q2=3.0, W=2.32
|
121
|
- 5 iterations with same functional form as Q2=4.4
|
122
|
- high epsilon, highest 2 t-bins:
|
123
|
- some very low Data/MC ratios around phi=0, corresponding to right SHMS
|
124
|
setting
|
125
|
- overlay of Data and MC histos for kinematic quantities
|
126
|
- MC has a double hump in W compared to data
|
127
|
- lowest 2 t-bins have nice ratios
|
128
|
|
129
|
- Q2=4.4, W=2.74
|
130
|
- Data/MC ratios overall look good
|
131
|
- some shift between data and MC for Q2, W distributions
|
132
|
- separated cross sections
|
133
|
- sigL<sigT in general, but 3rd t-bin has sigL high compared to the others
|
134
|
|
135
|
- planned systematic studies
|
136
|
- presents a summary of systmatic error types from KaonLT proposal
|
137
|
|
138
|
Vijay
|
139
|
-----
|
140
|
Low Q2 pion absorption correction study
|
141
|
- removed PID cuts from Alicia's script since he is using CoinTime and RF cuts
|
142
|
instead of Cherenkov
|
143
|
- getting a smaller correction factor than Alicia at low pion momentum
|
144
|
|
145
|
- next step will be to finalize Q2=0.425 yields
|
146
|
|
147
|
Nacer
|
148
|
-----
|
149
|
Low Q2 KaonLT LT-sep analysis
|
150
|
- working on average kinematic variables per t-bin
|
151
|
- averages are calculated after pion-leakthrough and Dummy subtractions
|
152
|
- had to replay data because theta* was missing from ROOT trees
|
153
|
- formed R=Data/MC ratios for each t-phi bin
|
154
|
- then form weighted average R per t-phi bin
|
155
|
- when combining ratios, if counts=0 set error=100 so it doesn't contribute
|
156
|
to weighted average
|
157
|
|
158
|
- found an error in boiling factor when computing yields
|
159
|
- also needs to correctly propagate the uncertainty in the beam current/charge
|
160
|
- for KaonLT BCM calibrations, see Dave Mack's report:
|
161
|
https://hallcweb.jlab.org/doc-public/ShowDocument?docid=1034
|
162
|
|
163
|
- Lambda: low epsilon, R about 2
|
164
|
- high epsilon, some random bins are zero, overall R about 2
|
165
|
- *NB* Richard: suggests to make MM plots for each t-phi bin to better see
|
166
|
what's going on, maybe the pion subtraction needs adjustment?
|
167
|
|
168
|
- Sigma: R about 8
|
169
|
|
170
|
Alicia
|
171
|
------
|
172
|
u-channel analysis
|
173
|
- incorporating Pythia generator for high MM background into SIMC
|
174
|
- got output files from Pythia into SIMC
|
175
|
- Sylvester Joosten had added a lot of containerization to SIMC for ANL
|
176
|
cluster that Alicia removed
|
177
|
- still getting some code crashes
|
178
|
- hoping to have some plots by next week
|
179
|
|
180
|
Next Meeting
|
181
|
-------------
|
182
|
- Thur May 23 @ 15:30 Eastern/13:30 Regina
|
183
|
- KaonLT will go first
|
184
|
** THIS TIME WILL BE USED AT LEAST UNTIL THE END OF AUGUST **
|
185
|
|
186
|
|
187
|
|