Project

General

Profile

Kaon LT Meetings » History » Version 119

Richard Trotta, 05/13/2020 03:18 PM

1 116 Richard Trotta
{{>TOC}}
2 1 Richard Trotta
3
h1. *Kaon LT Meetings*
4
5 96 Stephen Kay
Kaon LT collaboration analysis meetings. Please add your talk to the meeting ahead of time. Add the newest meeting to the top of the list!
6
7 95 Stephen Kay
----
8 113 Richard Trotta
9 112 Richard Trotta
----
10 1 Richard Trotta
11 111 Richard Trotta
h2. 2020 Meetings
12
13 118 Stephen Kay
h3. May 13, 2020
14
15 119 Richard Trotta
*Links to talks->* "Stephen":https://redmine.jlab.org/attachments/download/993/KaonLT_Meeting_13_05_20.pdf "Richard":
16 118 Stephen Kay
17
Next meeting 
18
19 111 Richard Trotta
h3. April 29, 2020
20
21 106 Richard Trotta
*Links to talks->* "Richard":https://redmine.jlab.org/attachments/download/984/KaonLTMeeting_4_29_20.pdf "Stephen":https://redmine.jlab.org/attachments/download/985/KaonLT_Meeting_29_04_20.pdf "Mark's hcana tracking update":https://redmine.jlab.org/attachments/download/982/Updates-to-HCANA-tracking.pdf
22
23 117 Richard Trotta
Next meeting May 13th @ 4:30 ET
24 106 Richard Trotta
25 1 Richard Trotta
----
26 106 Richard Trotta
27 111 Richard Trotta
h3. April 15, 2020
28 104 Richard Trotta
29 102 Richard Trotta
*Links to talks->* "Richard":https://redmine.jlab.org/attachments/download/977/KaonLTMeeting_4_15_20.pdf
30 105 Richard Trotta
31 102 Richard Trotta
Next meeting April 29th @ 4:30 ET
32 1 Richard Trotta
33 102 Richard Trotta
----
34 95 Stephen Kay
35 111 Richard Trotta
h3. April 1, 2020
36 100 Stephen Kay
37 95 Stephen Kay
*Links to talks->* "Stephen":https://redmine.jlab.org/attachments/download/949/KaonLT_Meeting_01_04_20.pdf "Richard":https://redmine.jlab.org/attachments/download/948/KaonLTMeeting_4_1_20.pdf
38 101 Richard Trotta
39 1 Richard Trotta
Next meeting April 15th @  4:30 ET
40 101 Richard Trotta
41 41 Stephen Kay
----
42 93 Richard Trotta
43 111 Richard Trotta
h3. March 18, 2020
44 93 Richard Trotta
45
*Links to talks->* "Richard's EIC Temple Draft 2":https://redmine.jlab.org/attachments/download/942/DRAFT2_mesonSF_EIC_Temple.pdf
46 1 Richard Trotta
47 94 Richard Trotta
Next meeting April 1st @  4:30 ET
48 93 Richard Trotta
49
----
50 91 Richard Trotta
51 111 Richard Trotta
h3. March 11, 2020
52 92 Richard Trotta
53 1 Richard Trotta
*Links to talks->* "Ali":https://redmine.jlab.org/attachments/download/940/KaonLT_Meeting_Mar_11.pdf "Richard's EIC Temple Draft 1":https://redmine.jlab.org/attachments/download/941/DRAFT1_mesonSF_EIC_Temple.pdf
54 94 Richard Trotta
55
Next meeting March 18th @  4:30 ET
56 91 Richard Trotta
57
----
58 88 Richard Trotta
59 111 Richard Trotta
h3. Feb 26, 2020
60 90 Richard Trotta
61
* Peter's changes to hcana should be coming soon. Richard will check with Mark when he is down there for an update.
62
* Need to incorporate the latest "BCM updates":https://hallcweb.jlab.org/doc-public/ShowDocument?docid=1034 from Dave Mack.
63 1 Richard Trotta
* Richard should look at the luminosity scalar analysis before and after the BCM changes once he gets his script working again.
64 88 Richard Trotta
**  He is checking with Mark about this while he is down in jlab. 
65 1 Richard Trotta
66 88 Richard Trotta
Next meeting March 11th @  4:30 ET
67 86 Richard Trotta
68 1 Richard Trotta
----
69 86 Richard Trotta
70 111 Richard Trotta
h3. Feb 10, 2020 
71 87 Richard Trotta
72 86 Richard Trotta
Next meeting Feb 26th @ 11 am ET
73
74
----
75 1 Richard Trotta
76 111 Richard Trotta
h3. Jan 22, 2020
77 83 Richard Trotta
78
*Links to talks->* "Richard's Hall C Winter Talk Draft 1":https://redmine.jlab.org/attachments/download/937/KaonLTHallC_WinterTalk2020_Draft1.pdf
79 85 Richard Trotta
80
Next meeting Feb 10 @ 11 am ET
81 83 Richard Trotta
82 1 Richard Trotta
----
83 83 Richard Trotta
84 111 Richard Trotta
h3. Jan 15,2020
85 81 Richard Trotta
86 82 Richard Trotta
*Links to talks->* "Richard's Hall C Winter Talk Outline":https://redmine.jlab.org/attachments/download/936/KaonLTHallC_WinterTalk2020.pdf
87 81 Richard Trotta
88 84 Richard Trotta
Next meeting Jan 22 @ 11 am ET
89 81 Richard Trotta
90
----
91 78 Richard Trotta
92 111 Richard Trotta
h3. Jan 8,2020
93 78 Richard Trotta
94 1 Richard Trotta
*Links to talks->* "Richard":https://redmine.jlab.org/documents/76
95 79 Richard Trotta
96 1 Richard Trotta
* Richard
97
** PID efficiency script is coming together
98
*** Tighter cuts and cuts on timing, beta, etc. will be needed for cleaner electron cuts
99
*** Hcal cut should be changed to cut around the mean normalized value instead of cutting above or below it only. This will assure electrons aren't lost.
100
101
Next meeting will be January 15th at 4 pm ET 
102 80 Richard Trotta
103
----
104 113 Richard Trotta
105 112 Richard Trotta
----
106 80 Richard Trotta
107 111 Richard Trotta
h2. 2019 Meetings
108
109
h3. Dec 17,2019
110
111 77 Richard Trotta
Reminder: Mark Jones' commissioning analysis meetings are bi-weekly and announced by Mark
112
113
* Stephen
114
** Number of passes finished for HMS calorimeter
115
*** Still wiggles in all passes
116
** Finished his report on calibrations, "DC and Calorimeters":https://redmine.jlab.org/documents/74
117
** Put together a list of people's jobs from Regina over the next couple of months, "Regina Analysis Tasks":https://redmine.jlab.org/documents/75
118
*** CUA will be putting together a similar list
119 1 Richard Trotta
120 77 Richard Trotta
* Richard
121
** Fixed one error issue with SHMS calorimeter calibration code (discussed Dec 10th meeting), but still have one error
122
** PID efficiency script plots are complete, but still some questions he needs to work out before a final version
123
*** Eventually need to include tracking into PID efficiencies
124
** Pete brought up the question for a number of multi-hits we are getting
125
*** (Dead Time)+(Trigger efficiency)-EDTM
126
127
Next meeting will be after the break; Wednesday, January 8th at 3 pm ET
128
129
----
130 72 Richard Trotta
131 111 Richard Trotta
h3. Dec 10,2019
132 72 Richard Trotta
133 74 Richard Trotta
*Links to talks->* "Richard":https://redmine.jlab.org/documents/73
134
135
* Garth and Stephen were in the most recent SIDIS meeting
136
** Wit had lots of hcana changes but they seem to be critical to our work 
137
*** Changes such as new detector classes
138 1 Richard Trotta
** Hopefully Wit will present these in the next commissioning meeting
139
140 77 Richard Trotta
* Stephen improved wiggles but still prevalent
141 74 Richard Trotta
142
* Richard finished HGCer calibrations, he concluded that the online parameters are sufficient
143
** He also has been looking at SHMS calorimeter calibrations but has had issues running the scripts. Most likely a pathing issue.
144
** The "tasks":https://redmine.jlab.org/projects/kltexp/wiki/Analysis_Tasks page has been updated with a section for efficiencies. 
145
*** A PID efficiency script is currently being developed and hopefully should have some plots for our next meeting.
146
147 1 Richard Trotta
* Next meeting will be December 17th at 3 pm ET.
148 74 Richard Trotta
149 75 Richard Trotta
----
150 74 Richard Trotta
151 111 Richard Trotta
h3. Nov 26,2019
152 71 Richard Trotta
153
*Links to talks->* "Richard":https://redmine.jlab.org/issues/480
154
155
* Stephen
156
** DC SHMS, small-angle has poor performance
157
*** Tighter cuts or PID (currently only looks for electrons)
158
** Vardan said calorimeter wiggles are an ongoing issue with no current solution
159
160
* Richard
161 1 Richard Trotta
** The calibrations are nearing completion with only the HG Cherenkov and SHMS calorimeter yet to be finished. There are also smaller issues with some DC and HMS calorimeter runs.
162 71 Richard Trotta
*** Richard will pick up looking at the HGCer calibrations from Vijay's scripts. 
163
*** Richard will also be looking at the SHMS calorimeter and with the suggestion of getting some negatively polarized SHMS runs from Hem.
164
** The HMS Cherenkov is finished with the conclusion that the calibrations from the online runs are good
165
** We can begin looking forward towards efficiencies. 
166
*** Garth suggested that looking at PID may be an advantageous first steps. Precise definitions of these PIDs will need to be logged.
167
*** Clear notes on efficiencies steps will be needed. They will need to be redefined multiple times in multiple ways. 
168
169
* Hem
170
** Has been looking at the calorimeter as well. 
171 70 Richard Trotta
** He has seen the second band in the spectra for some runs, we suggested further looks into HMS hodoscope and subsequently reference times. A recalibration will need to be performed.  
172
173
----
174
175 111 Richard Trotta
h3. Nov 19,2019
176 1 Richard Trotta
177 70 Richard Trotta
*Links to talks->* "Stephen":https://redmine.jlab.org/issues/500 "Richard":https://redmine.jlab.org/issues/500
178
179
* Richard
180
** Finished up TDC cut paper going through the procedure (found "here":https://redmine.jlab.org/issues/500)
181
** Needed to add Carlos pre-trigger designs to an appendix for the paper which clarifies the introduction section
182
183
* Stephen
184
** Issues with DC calibration for only a few runs during each run period
185
** "wiggles" in HMS calorimeter calibrations for some runs
186
*** few runs where HMS cal totally failed (which was dependent on initial parameters)
187
*** Spring looked worse than the rest (surprisingly), but this may be because online calibration wasn't great
188
189 2 Richard Trotta
----
190 68 Richard Trotta
191 111 Richard Trotta
h3. Nov 5,2019
192 68 Richard Trotta
193
*Links to talks->* "Stephen":https://redmine.jlab.org/issues/500
194
195
* Timing update (Stephen)
196
** Reference times between Richard and Stephen are very similar and the GitHub is updated accordingly
197
** Richard is going to add the trigger time cuts once the fall runs are finished (by end of week)
198
** First pass of detector reference time parameter files finished
199 1 Richard Trotta
200 68 Richard Trotta
* Peter's hcana code (Richard and Stephen)
201
** Peter's code does not remove ghost bands (already known), but now Stephen is seeing a strang horizontal band for just SHMS hodoscope 2D plots
202
*** Richard has emailed Peter about the issue with no response yet (follow-up soon)
203
** This means we still need the reference time amplitude cut with Peter's code but using just the amplitude cut with Mark's latest version of hcana should be sufficient for calibrations.
204
205
* Calibrations were decided to be done once per shift
206
207
* Next meeting schedule...
208
** Small meetings Nov 12 and Nov 19 (at 3pm ET) so Richard and Stephen can iron out the timing and calibrations
209
** November 26 (at 3pm ET) will be a larger meeting. 
210
*** This is the rough deadline we made for finishing up calibrations. 
211
*** This should be sufficient for all detectors (although hodoscope and HG which may persist). The ultimate goal is for all calibrations to be finished up before Winter break!!
212
213
----
214
215 111 Richard Trotta
h3. Oct 22,2019
216 62 Richard Trotta
217 64 Richard Trotta
*Links to talks->* "Stephen":https://redmine.jlab.org/issues/500 "Richard":https://redmine.jlab.org/issues/500
218 62 Richard Trotta
219 65 Richard Trotta
* SHMS Reference Time Amplitude Cuts(Stephen)
220
** Extra peaks in HG from cross-talk and "ghost-bands" due to ADC screw up
221
*** cuts applied on SHMS ADC ref time amplitude (greater than zero) done before any further event selection and histogram filling
222
** This is a temporary fix to "ghost-bands" and cross talk
223
*** Although for HG there is still a small peak. The hodoscope is fine.
224
** The time window is easier to set now.
225
** DC has been fine (since it uses TDC)
226
*** DC calibrations should be good to complete, other detectors need more fixes (i.e. the remaining "ghost-band")
227
** Hodoscope still bad but this might be because of that "ghost-band", needs to be further investigated
228
229 1 Richard Trotta
* Peter's hcana fixes for reference time (Richard)
230 67 Richard Trotta
** Peter implemented changes to hcana
231
** Two major issues...
232 1 Richard Trotta
## Amplitude goes to null and integral is low or negative which causes a rate-dependent efficiency. 
233 67 Richard Trotta
*** Peter has used the average pulse value acquired over a large sample of runs for each detector. 
234 1 Richard Trotta
## Timing offset between EL-REAL and 3/4 is 130 ns which causes junk tracks at high SHMS rates (~6% of the time)
235 67 Richard Trotta
*** Peter created a routine to find the best offset by means of matching TDC and ADC
236
** Richard has been checking for bugs in the code. 
237
*** It seems to be ready to implement, Richard emailed Peter for confirmation on the implementation in our group directory
238
239 1 Richard Trotta
* Calibration of HMS detectors when the timing is agreed upon by Stephen and Richard.
240 67 Richard Trotta
** Besides hodoscope which still has an issue with the script
241 65 Richard Trotta
** Stephen and Richard are having a meeting late next week to determine time window values
242 62 Richard Trotta
*** These will be relatively final, but on the wider side if adjustments need to be made in the future
243
244 1 Richard Trotta
-----
245 61 Richard Trotta
246 111 Richard Trotta
h3. Sep 24,2019
247 61 Richard Trotta
248
*Links to talks->* "Stephen":https://redmine.jlab.org/issues/500 "Richard":https://redmine.jlab.org/issues/500
249 1 Richard Trotta
250 61 Richard Trotta
-----
251 1 Richard Trotta
252 111 Richard Trotta
h3. Sep 10,2019
253 59 Vijay Kumar
254
*Links to talks->* "Stephen":https://redmine.jlab.org/documents/69 "Ali":https://redmine.jlab.org/documents/72 "Richard":https://redmine.jlab.org/issues/500
255 1 Richard Trotta
256
-----
257 55 Stephen Kay
258 111 Richard Trotta
h3. August 26, 2019
259 55 Stephen Kay
260
*Links to talks->* "Stephen":https://redmine.jlab.org/documents/69 "Ali":https://redmine.jlab.org/documents/70 "Vijay":https://redmine.jlab.org/documents/71 "Richard":https://redmine.jlab.org/issues/500
261 1 Richard Trotta
262 54 Richard Trotta
----
263
264 111 Richard Trotta
h3. June 21, 2019
265 54 Richard Trotta
266 1 Richard Trotta
*Links to talks->* "Hallc Talk Outline":https://redmine.jlab.org/documents/60 
267 54 Richard Trotta
268 42 Stephen Kay
----
269
270 111 Richard Trotta
h3. June 14, 2019
271 1 Richard Trotta
272 46 Richard Trotta
*Links to talks->* "Hallc Talk Outline":https://redmine.jlab.org/documents/60 "Mireille":https://redmine.jlab.org/documents/64 "Update-Mireille":https://redmine.jlab.org/documents/65 "Vijay":https://redmine.jlab.org/attachments/download/814/Analy_update3.pdf
273 42 Stephen Kay
274
275 35 Stephen Kay
----
276 1 Richard Trotta
277 111 Richard Trotta
h3. June 4, 2019
278 36 Vijay Kumar
279 1 Richard Trotta
*Links to talks->* "Stephen":https://redmine.jlab.org/documents/56 "Nathan":https://redmine.jlab.org/documents/57 "Vijay":https://redmine.jlab.org/documents/58 "Richard":https://redmine.jlab.org/documents/59 "Hallc Talk Outline":https://redmine.jlab.org/documents/60 "Mireille":https://redmine.jlab.org/documents/61
280 35 Stephen Kay
281 1 Richard Trotta
282 35 Stephen Kay
----
283 1 Richard Trotta
284 111 Richard Trotta
h3. May 21, 2019
285 1 Richard Trotta
286
*Links to talks->* "Richard":https://redmine.jlab.org/documents/52 "Mireille":https://redmine.jlab.org/documents/? "Stephen":https://redmine.jlab.org/documents/53 "Nathan":https://redmine.jlab.org/documents/54 "Vijay":https://redmine.jlab.org/documents/55
287 35 Stephen Kay
288
----
289 1 Richard Trotta
290 111 Richard Trotta
h3. May 14, 2019
291 1 Richard Trotta
292 35 Stephen Kay
*Links to talks->* "Richard":https://redmine.jlab.org/documents/48 "Carlos' slides":https://redmine.jlab.org/documents/49 "Mireille":https://redmine.jlab.org/documents/50 "Stephen":https://redmine.jlab.org/documents/51
293 1 Richard Trotta
294 35 Stephen Kay
----
295 1 Richard Trotta
296 111 Richard Trotta
h3. April 30, 2019
297 1 Richard Trotta
298
*Links to talks->* "Richard":https://redmine.jlab.org/documents/45 "Richard's slides in wiki":https://redmine.jlab.org/projects/kltexp/wiki/Analysis_How-To "Brad Computing":https://redmine.jlab.org/documents/46 "Stephen":https://redmine.jlab.org/documents/47
299 35 Stephen Kay
300 1 Richard Trotta
----
301
302
h3. February 4, 2019
303 111 Richard Trotta
304 1 Richard Trotta
*Links to talks->* "Richard":https://redmine.jlab.org/documents/43 "Stephen":https://redmine.jlab.org/documents/44
305
306
----
307 113 Richard Trotta
308 112 Richard Trotta
----
309 1 Richard Trotta
310 111 Richard Trotta
h2. 2018 Meetings
311
312
h3. August 21, 2018
313
314 1 Richard Trotta
*Ongoing Tasks->* #381 #382 #383 #404 #405 #406
315 35 Stephen Kay
316 1 Richard Trotta
----
317 35 Stephen Kay
318 111 Richard Trotta
h3. August 8, 2018
319 35 Stephen Kay
320
*Ongoing Tasks->* #381 #382 #383 #404 #405 #406
321 1 Richard Trotta
322
----
323 35 Stephen Kay
324 111 Richard Trotta
h3. August 3, 2018
325 1 Richard Trotta
326 35 Stephen Kay
*Ongoing Tasks->* #381 #382 #383
327
*Links to talks->*
328 1 Richard Trotta
329 35 Stephen Kay
----
330 1 Richard Trotta
331 111 Richard Trotta
h3. July 11, 2018
332 1 Richard Trotta
333 35 Stephen Kay
*Ongoing Tasks->* #381 #382 #383 #384
334 1 Richard Trotta
335 35 Stephen Kay
*Action items:*
336 1 Richard Trotta
337 35 Stephen Kay
* Update run plan, e.g. add prescales (Garth)
338
* Check on details of: magnet cycling procedure, minimum angles, MCC fringe field steering, beam energy measurements, optics checks (Tanja)
339
* Identify additional run coordinators (Tanja)
340
* Encourage collaborators to take shifts, e.g. FIU (Pete)
341
* Draft email about shifts etc. to collaboration (Tanja)
342
* Develop diagnostic scripts and kaonLT specific (Richard, Ryan)
343
* Continue documentation development, e.g. checklist, shift taker instructions, HowTo or link to generic Hall C HowTo, task list, web page (Richard, Garth)
344 1 Richard Trotta
345 35 Stephen Kay
*Discussions:*
346
347
* SHMS Aerogel Cherenkov: tray has been changed to SP-11 on 10 July, nominal time for change is 8 hours, one tray can stay in the hall to minimize overhead
348
* HGC: waiting for re-installation
349
* Trigger checkout: main items to keep in mind: fADC thresholds, timing HMS/SHMS - leading arm, possible rate limitations
350 1 Richard Trotta
* Shifts
351
* Diagnostics scripts and documentation
352
* Personnel schedules
353
354
----
355
356 111 Richard Trotta
h3. June 28, 2018
357 1 Richard Trotta
358
*Links to talks->* "Richard":https://redmine.jlab.org/documents/34
359
360
*Action Items:*
361
362
* Develop and post shift schedule. Send out request. Find out who is KAONLT liaison (Tanja)
363
* Contact potential run coordinators. (Tanja)
364
* Aerogel tray exchange for start of experiment and coordination of future exchanges (Vladimir)
365
* Update runplan and prepare documents needed for shift crew, e.g. run sheets (Garth)
366
* Set up a web page to collect and link from Redmine - How-To documents, initial calibrations, etc. (Garth, Richard)
367
* Adapt luminosity scan script to calculate kaon yields by run number for use during experiment by shift crew - has to be simple to use. (Richard)
368
* Develop trigger/detector checkout plan (Tanja, initial draft)
369
** Are all experts available at run start, experts needed: coincidence timing , Harp Scans, BCM calibrations, ...
370
* Find out from JLab what the anticipated settings are for limit switches for both spectrometers and for separation angle in between them. Also find out what magnet cycling procedure should be used for L/T quality separation data (Tanja)
371
* Find out if all aerogel trays needed for experiment can be stored inside Hall C to avoid having to open truck ramp (Vladimir)
372
373
*Analysis Updates:*
374
375
* Ryan 
376
** resolving differences between his analysis and Richard's
377
378
* Richard
379
** Discussed with Mark Jones and is cross checking his January luminosity scan analysis against Mark's. Realized that BCM calibrations (gains, offsets etc) are different - currently working on fixing that, presents current results - low curent point is ~10% below unity, discussion that this seems to indicate that BCM offsets are the issue as low current points would be most sensitive, is planning to also double-check the BCM calibration procedure - had discussion with Dave Mack at JLab
380
** Presents a script developed for luminosity scans that determines yields for a run number input on command line. Discussion this could be good to adapt for kaon counting during experiment.
381
382
----
383
384 111 Richard Trotta
h3. May 31, 2018
385 1 Richard Trotta
386 35 Stephen Kay
*Links to talks->* "Samip":https://redmine.jlab.org/documents/30
387 1 Richard Trotta
388 35 Stephen Kay
----
389 1 Richard Trotta
390 111 Richard Trotta
h3. May 17, 2018 
391 1 Richard Trotta
392 35 Stephen Kay
*Links to talks->* "Richard":https://redmine.jlab.org/documents/29, "Ryan":https://hallcweb.jlab.org/DocDB/0009/000968/001/Presentation.pdf, "Samip":https://redmine.jlab.org/documents/30
393 2 Richard Trotta
394 35 Stephen Kay
* Luminosity scans (Richard, Ryan)
395 111 Richard Trotta
** Carbon scan from April seems consistent with no boiling, LH3 and LD2 show deviation from unity, should check effect of EDTM events on efficiencies
396 35 Stephen Kay
** Carbon scans from January (low rates) have large deviations from unity, in particular behavior at higher currents (>40uA), e.g. cpu dead time, that is not yet understood
397
** discussion about pre-scale factors
398 1 Richard Trotta
399 35 Stephen Kay
* Discussion about Richard's script extracting and printing information from report files and trees including histograms
400
** Add option for looking at yields with cuts on cointime, target window, and missing mass
401
** Add option to look at real peak vs. background level
402 1 Richard Trotta
403 35 Stephen Kay
* H(e,e'p) kinematics investigation for fall run (Samip)
404
** Optimal range is between electron angles of 17-20 degrees, time required ranges from ~1 hour at 17 degrees to ~3 hour at 20 degrees, other angles may be of interest for disentangling charge and current dependent effects
405 1 Richard Trotta
406 35 Stephen Kay
* *Action Items*
407
** Luminosity scans at low rates from January (Richard)
408
** Luminosity scans from April with corrected efficiencies, e.d. DT (Ryan)
409
** H(e,e'p) and H(e,e') kinematics for upcoming Kaon LT run (Samip)
410
** Kaon LT detailed run plan (Garth, Pete, Tanja)
411
** Preparations, e.g. report files, diagnostic histograms and real time monitoring, shift worker instructions, optimization of trees (all)
412 1 Richard Trotta
413
----
414
415 111 Richard Trotta
h3. May 10, 2018
416 35 Stephen Kay
417 2 Richard Trotta
*Links to talks->* "Hem":https://redmine.jlab.org/documents/24, "Richard":https://redmine.jlab.org/documents/23, "Ryan, ":https://redmine.jlab.org/documents/20 "Samip":https://redmine.jlab.org/documents/26
418 35 Stephen Kay
419
* Luminosity Scans January 2018 (Richard)
420
** Tracking-based analysis for Runs 1415-1423, .. for now focus on HMS, typical HMS S1X rates are <
421
** Cuts applied: PID for electrons (Cer, Cal), acceptance (delta)
422
** Efficiency calculation was investigated in detail and applied using scalers from trees
423
** Results for carbon (normalized to 30uA) show large variation - need to understand
424
** *Next steps:*
425
*** Double check calculation of computer lifetime, look for differences in TRIG and PRETRIG scalers
426
*** Check stability of pre-scale (Ryan saw changes within runs)
427
*** Check if detector calibrations for runs are implemented correctly
428
*** Analyze with Ryan's cuts
429 1 Richard Trotta
430 35 Stephen Kay
* Luminosity Scans April 2018 (Ryan)
431
** Confirms Richard's earlier finding that scaler-based analysis is not reliable and that it's best to analyze event-by-event
432
** Tracking-based analysis for runs 2073-2095
433
** Cuts applied: PID for electrons (TOF, Cal, Chi2), acceptance (delta and angles), BCM4a
434
** Included most recent detector calibrations in replay of these runs
435
** Efficiencies from report file mainly, may need to update tracking efficiency implementation
436
** Found that calculations of computer deadtime requires different set of scalers for runs from January to those from April 2018
437
** Results show carbon yields consistent with unity within error (0.5% error bars), and boiling for hydrogen and deuterium
438
** *Next steps:*
439 5 Richard Trotta
*** Check tracking efficiency
440 35 Stephen Kay
441
* *Global comments on Luminosity Scans (so far)*
442 1 Richard Trotta
** April 2018 scans show hydrogen and deuterium target boiling on level of 3-4%, Carbon is consistent with no boiling, as expected - based on description, new targets are expected to have less boiling than those used previously, e.g. in FPI2. Double check this.
443 35 Stephen Kay
** Efficiencies in report files need to be updated, e.g. CPU deadtime (Richard)
444
** Check if BCM4a is the one closest to the target - get a map of the hall (Richard, Ryan)
445
** Uncertainties on current
446
** Detector calibrations
447 1 Richard Trotta
** HMS vs. SHMS
448 35 Stephen Kay
449
* eK+ coincidence time from SIDIS Spring 2018 run (Samip)
450
** Worked with Mark Jones on coincidence time calculation - now available in hcana (see Samip's 10 May 2018 email for more details)
451
** runs used in this analysis: 3423 with Q2=3.1 GeV2 and W=2.78 GeV
452
** Coincidence time spectrum shows peak separations >2 ns corresponding to different accelerator frequency
453
** Missing mass spectra: Kaon peak clearly visible, also see pions even after cuts
454
** Found that pions appear localized in phase space - seems to be due to end point in kinematic phase space
455 1 Richard Trotta
** *Next steps:*
456 2 Richard Trotta
*** Look for a run with kaon momentum closer to 3 GeV/c (aerogel threshold is ~3 GeV/c for kaons for n=1.015)
457 35 Stephen Kay
458
* Yield normalized ratios from SIDIS (Hem)
459
** Yield ratios of data to MC match well in shape, but normalization seems not quite right
460
** *Next steps:*
461 4 Richard Trotta
*** Check if efficiencies, currents, run time etc. are taken into account correctly
462
463
----
464 35 Stephen Kay
465 111 Richard Trotta
h3. April 26, 2018
466 4 Richard Trotta
467 35 Stephen Kay
*Links to talks->* "Richard,":https://redmine.jlab.org/documents/18 "Ryan, ":https://redmine.jlab.org/documents/20 "Samip":https://redmine.jlab.org/documents/25
468 4 Richard Trotta
469 35 Stephen Kay
* Discussion luminosity scan analysis (earlier scan) - Richard
470
** Shown is a scaler-based analysis using scalers from report file and from ROOT tree - the values are different, why that is has to be checked
471
** Notes on efficiencies in report file:
472
*** DT (EDTM) is not electronic deadtime. Instead use for now 50ns* trigger rate for HMS and 100ns* trigger rate for SHMS
473
*** Cherenkov efficiency seems low (check if that is due to PID, thresholds, pi/e, etc)
474
*** Tracking efficiency needs to be checked
475
*** 3/4 trigger efficiency seems ok
476
* Discussion luminosity scan analysis (later scan) - Ryan
477
** Fewer carbon runs than earlier scan
478
** Shown is a tracking-based analysis using data from the ROOT trees
479 111 Richard Trotta
** First results for carbon, LH3, and LD2, but efficiencies need to be checked
480 35 Stephen Kay
* SIDIS analysis - Hem
481
** Shown is a data/MC comparison for different kinematic settings. Agreement in shape is very good. Normalization has yet to be applied.
482
** Discussion about agreement in z and apparent offset - relation of this offset with spectrometer offset
483
* Analysis of exclusive events in SIDIS - Samip
484
** Shown is a look at the first kaon events in exclusive limit of SIDIS data
485
** Ongoing work on implementing coincidence time into tree
486
* Discussion of run plan, and in particular possible low Q2/low energy
487
** Assume that kaon low Q2=0.4 already included - have kinematics with specified beam energies, if needed
488
** For pion form factor and LT, have two possible settings that can use the prescribed beam energies: Q2=1.45 and 0.35 GeV2 - prioritize towards the higher Q2 as not as sensitive to offsets
489
** Garth will put this together in a draft email
490
491 12 Richard Trotta
----
492
493 111 Richard Trotta
h3. March 29, 2018
494 12 Richard Trotta
495 35 Stephen Kay
*Links to talks->* "Richard, ":https://redmine.jlab.org/documents/16 "Samip":https://redmine.jlab.org/documents/27
496 13 Richard Trotta
497 35 Stephen Kay
* Details of adding points to fall run plan - will be ready sooner, likely in week of 4/1 (Garth, Samip, Tanja)
498
* Luminosity scans (Ryan, Andres, Richard, Pete)
499
* Macros, SIDIS analysis (Hem, Anashe)
500
* Elastic data (TBD)
501
502 14 Richard Trotta
----
503 18 Richard Trotta
504 111 Richard Trotta
h3. February 22, 2018
505 18 Richard Trotta
506 35 Stephen Kay
*Links to talks->* "Andres":https://redmine.jlab.org/documents/19
507 18 Richard Trotta
508 35 Stephen Kay
*  Discussion of Andres' slides on elastic W calculation in hcana - initial issue with negative W values seems to be due to outdated information in standard.kinematics file. Additional investigation ongoing.
509
* Brief description of Samip's work - working on coincidence timing decoding with JLab staff and re-optimization of kinematics
510
* Discussion of Richard's slides on run plan kinematics and preparations -
511
** everyone agrees that in general want to have as many L/T cross section separations as possible in a robust run plan balancing statistics vs. systematics
512
** before actual run may want to do a 3D optimization in all kinematic variables to get the best possible delta(epsilon) for the L/T separations
513
** for each setting will need 1-2 shifts for calibrations - need to negotiate with other experiments in run group
514
** kinematics plots W-Q2 show that still need to do some optimization
515
** run sheets: include raster size, update coincidence count labeling, and carbon target labeling
516
* Discussion of next meeting. Garth at JLab 8-16 March - might have meeting during that time.
517 26 Richard Trotta
518 35 Stephen Kay
* *Action Items:*
519
** Post slides/notes from this meeting and procedure to set up hcana in Redmine (Tanja)
520
** Update run sheet and kinematic optimization for W/Q2 (Garth)
521
** Circulate elastic calculations for kinematic settings (Samip)
522
** Continue investigation of elastic data and run plan kinematics (Andres/Richard)
523
** Test software installation instructions (Pete)
524
** Draft email to JLab management about need for small angle beam pipe - need to have HMS minimum angle of less than 13 degrees for kaon L/T separations (Tanja) 
525 32 Stephen Kay
526
----