h1. Fermilab Test Beam Run h2. Run List beam hit the edge of top Ecal New HV is: 1260, 1300, 920, 960, 940, 1940, 1780, 2100 Run 777 First run - MWPC trigger - New HV is: 1260, 1300, 920, 960, 940, 1840, 1680, 2000 783 Preshower channels set to 2V range in FADC 784 TS1 and TS2 - move detector position so beam is hitting the center of three ECals 785 New HV is: 1160, 1200, 820, 860, 840, 1840, 1680, 2000 786 TS1 only - beam centered on calorimeter New HV is: 1260, 1300, 820, 860, 840, 1740, 1580, 1900 787 lower HV on preshower 788 792 reduce 100 V more on preshower 793 short run PEB1 crashed switch to FADC only config TiIntelvmeha8 795 Changing down stream Cerenkov N2 pressure 796 move to Top block 800 beam on the center of the top block, point A 801 802 beam on the center of the right block, point C 803 beam on the center of the left block, point A 804 beam on the center of 3 modules, 6.5k 805 2GeV, beam on the center of 3 modules, 31.7k 806 4GeV, beam on the center of 3 modules, 818 12 GeV e- 819 12 GeV e- 820 10 GeV e- 821 8 GeV e- 822 6 GeV e- ===========1GeV=================== HV is: 1260, 1280, 760, 860, 880, 1640, 1480, 1800 823 824 825 Switch to TS2 trigger 828 Switch back to TS1 831 839 daq crashed 847 1 GeV 848 6 GeV 849 6 GeV 850 6 GeV 851 6 GeV 851 Cherenkov test DAQ run 852 ?? 853 calibration run 854 calibration run 855 calibration run 856 calibration run 857 6 GeV 858 6 GeV 859 6 GeV 860 6 GeV 861 6 GeV 862 16 GeV 863 16 GeV 864 16 GeV 865 16 GeV. FADC saturated, bad run GeV 866 16 GeV. FADC saturated, bad run GeV 867 12 GeV h2. Shifter Roles * Leader: Communicate with MCR regarding desired beam energy and other relevant details. Manage the DAQ (start and stop runs) * Remote: Keep a shift log of actives during the shift. Decode runs as they are completed. Post a shift summary logbook entry at the conclusion of your shift. h2. VNC Connection Information (for Remote Shifts) * Using terminal, ssh into login and then the computer that has the VNC server on it ssh -L 5901:localhost:XXXX @janedoe@fnalu.fnal.gov@ Replace XXXX with a port number of your choice (avoid 22). Log in using JLab CUE credentials * In the same session, ssh to the computer: ssh -L XXXX:localhost:5901 @a-compton@clrlpc.dhcp.fnal.gov@ Log in using JLab CUE credentials for user a-compton. * On your machine, run the VNC application. When prompted for the VNC Server, use: localhost:5901 Encryption: Let VNC Server choose Enter password set up on the VNC server Log in using JLab credentials h2. How to make beam position plots using the MWPC data The MWPC folder is located at: /home/a-compton/MWPC/ Raw data at: /home/a-compton/MWPC/data decoder at: /home/a-compton/MWPC/analysis/basic A script to run decoder and make one figure of beam position is available here: /home/a-compton/MWPC/analysis/basic/wcsolid.csh You can run this script at any folder.