1. Runlist for fermilab beam test

beam hit the edge of top Ecal
New HV is: 1260, 1300, 920, 960, 940, 1940, 1780, 2100

777 First run - MWPC trigger -

783 Preshower channels set to 2V range in FADC, new HV is: 1260, 1300, 920, 960, 940, 1840, 1680, 2000

784 TS1 and TS2 - move detector position so beam is hitting the center of three ECals

785 New HV is: 1160, 1200, 820, 860, 840, 1840, 1680, 2000

786 TS1 only - beam centered on calorimeter

787 lower HV on preshower, New HV is: 1260, 1300, 820, 860, 840, 1740, 1580, 1900

788

792

793 reduce 100 V more on preshower, New HV is: 1260, 1300, 820, 860, 840, 1640, 1480, 1800
short run PEB1 crashed

795 switch to FADC only config TiIntelvmeha8 and use

Changing down stream Cerenkov N2 pressure

===========good data start from here===================

796 move to Top block, use this New HV: 1260, 1300, 880, 920, 940, 1640, 1440, 1800
797

798 move to left block

800 beam on the center of the left block, point A
801
802 beam on the center of the right block, point C

803 beam on the center of the top block, point A

804 beam on the center of 3 modules, 6.5k

805 2GeV, beam on the center of 3 modules, 31.7k

806 4GeV, beam on the center of 3 modules,

818 12 GeV e-
819 12 GeV e-
820 10 GeV e-
821 8 GeV e-
822 6 GeV e-

===========1GeV===================
HV is: 1260, 1280, 760, 860, 880, 1640, 1480, 1800
823
824
825
Switch to TS2 trigger, which is our own trigger

828

Switch back to TS1

831

839 daq crashed

847 1 GeV
===========6GeV===================

848 6 GeV
849 6 GeV
850 6 GeV
851 6 GeV

calibration start
853 center on the top block(1440, 252),
854 center on the left block (1498, 347)
855 center on the right block (1382, 347)
calibration end

858 bad run

===========16GeV===================
862, ecal HV is using 8GeV setting: 760, 860, 880 bad run, all saturated
863, change ecal HV: 720, 820. 840, bad run, all saturated
864 bad run, all saturated
865, change ecal HV: 700 780,800 bad run, sdu#5 saturated
866 bad run, sdu#5 saturated
===========12GeV===================
867
868
869

870 motion table moved to (1429,315)
871

872 motion table moved to (1452,315)
873
874

875 motion table moved to (1461,315)
876

877 motion table moved to (1451,315)

878 coda has 2 events less than MWPC daq
879 coda has 3 events less than MWPC daq
880 coda crashed, no output file
881
882 bufferlevel=2

883

884 Moved motion table from (1451, 315) vertical down by 2mm to (1451,313)
885

886 Moved motion table vertical down by 5mm to (1451,308)
887

888 Moved motion table vertical down by 3mm to (1451,305)
889

890 Moved motion table vertical down by 2mm to (1451,303)

891
892
893
894
895

896 coda crashed. 17661 events, data is still good
897 coda crashed, no output file
898
899
900
901 MWPC daq not start
902

calibration start
903 Moved table to (1451, 239), center on the top block
904 Moved table to (1510, 334), center on the left block
905 Moved table to (1393, 334), center on the right block
calibration end

===================16geV====================

920|921 Ecal HV: 620 700 720, beam hit center O
922|923 Move table, beam hit the Top block
924 Ecal HV: 620 680 720,
925 Move table, beam hit the Left block
926 MWPC daq not synchronize
927 MCR change beam spot size
928 Move table, beam hit the Right block