1. Runlist for fermilab beam test beam hit the edge of top Ecal New HV is: 1260, 1300, 920, 960, 940, 1940, 1780, 2100 777 First run - MWPC trigger - 783 Preshower channels set to 2V range in FADC, new HV is: 1260, 1300, 920, 960, 940, 1840, 1680, 2000 784 TS1 and TS2 - move detector position so beam is hitting the center of three ECals 785 New HV is: 1160, 1200, 820, 860, 840, 1840, 1680, 2000 786 TS1 only - beam centered on calorimeter 787 lower HV on preshower, New HV is: 1260, 1300, 820, 860, 840, 1740, 1580, 1900 788 792 793 reduce 100 V more on preshower, New HV is: 1260, 1300, 820, 860, 840, 1640, 1480, 1800 short run PEB1 crashed 795 switch to FADC only config TiIntelvmeha8 and use Changing down stream Cerenkov N2 pressure ===========good data start from here=================== 796 move to Top block, use this New HV: 1260, 1300, 880, 920, 940, 1640, 1440, 1800 797 798 move to left block 800 beam on the center of the left block, point B 801 802 beam on the center of the right block, point C 803 beam on the center of the top block, point A 804 beam on the center of 3 modules, 6.5k 805 2GeV, beam on the center of 3 modules, 31.7k 806 4GeV, beam on the center of 3 modules, 818 12 GeV e- 819 12 GeV e- 820 10 GeV e- 821 8 GeV e- 822 6 GeV e- ===========1GeV=================== HV is: 1260, 1280, 760, 860, 880, 1640, 1480, 1800 823 824 825 Switch to TS2 trigger, which is our own trigger 828 Switch back to TS1 831 839 daq crashed 847 1 GeV ===========6GeV=================== 848 6 GeV 849 6 GeV 850 6 GeV 851 6 GeV calibration start 853 center on the top block(1440, 252), 854 center on the left block (1498, 347) 855 center on the right block (1382, 347) calibration end 858 bad run ===========16GeV=================== 862, ecal HV is using 8GeV setting: 760, 860, 880 bad run, all saturated 863, change ecal HV: 720, 820. 840, bad run, all saturated 864 bad run, all saturated 865, change ecal HV: 700 780,800 bad run, sdu#4 saturated 866, bad run, sdu#4 saturated ===========12GeV=================== 867 868 869 870 motion table moved to (1429,315) 871 872 motion table moved to (1452,315) 873 874 875 motion table moved to (1461,315) 876 877 motion table moved to (1451,315) 878 coda has 2 events less than MWPC daq 879 coda has 3 events less than MWPC daq 880 coda crashed, no output file 881 882 bufferlevel=2 883 884 Moved motion table from (1451, 315) vertical down by 2mm to (1451,313) 885 886 Moved motion table vertical down by 5mm to (1451,308) 887 888 Moved motion table vertical down by 3mm to (1451,305) 889 890 Moved motion table vertical down by 2mm to (1451,303) 891 892 893 894 895 896 coda crashed. 17661 events, data is still good 897 coda crashed, no output file 898 899 900 901 MWPC daq not start 902 calibration start 903 Moved table to (1451, 239), center on the top block 904 Moved table to (1510, 334), center on the left block 905 Moved table to (1393, 334), center on the right block calibration end ===================16GeV==================== beam still hitting the right block---------------------------- 906|907 Ecal HV: 660 760 780, 908|909 Ecal HV: 700 780 800, 910|911 Ecal HV: 760 860 880, MCR start to shrink beam spot size 912|913 Ecal HV: 660 760 780, 914|915 Adjust Ecal HV, also Lower Preshower3 HV by 40V, new HV: 1260 1280 640 760 760 1640 1480 1760, 916 Move table back to center---------------------------- 917 918|919 920|921 Ecal HV: 620 700 720, beam hit center O 922|923 Move table, beam hit the Top block MCR cfinished changing beam spot size calibration start========= 924 Ecal HV: 620 680 720, Top block 925 Move table, beam hit the Left block 926 MWPC daq not synchronize 927 928 Move table, beam hit the Right block 929 calibration end ========= 930 Move table, beam hit the center of 3 blocks 931 932 933 934 935 936 937 938 coda has 3 events less than MWPC daq 939 MWPC not run 940 941 942 943 944 ===================2GeV==================== HVis set to : SC1 SC2 Ecal1 Ecal2 Ecal3 PrSh1 PrSh2 PrSh3 -1260 -1280 -760 -860 -880 -1640 -1480 -1800 945 946 947 948 daq crashed, no data 949 only 863 events 950 - 969 production ===================4GeV==================== 970 971 972 973 974 coda crashed, no output file 975 detector are below beam line, good for checking pedestal, in run 975, Cherenkov raw signal are connected to FADC, previously we connected the logical signal after DSC 976 detector are below beam line, good for checking pedestal 977 978 Upstream cherenkov HV changed from 1700 to 1640 984 coda crashed, no output file 985 987 change coda latency from 100 to 150 to test daq. 988 989 change coda latency back to 100 991 trash 995 Changed Cherenkov HVs from (1640,1700,1700) to (1600,1740,1720) . 996 stopped with only one spill. Did not synchronize to MWPC daq 997 ///////////////////// PMT: Up, Outer, Inner <=977: 1700,1700,1700 978-994: 1640,1700,1700 995-997: 1600, 1720, 1740 1740, 1720 998|999: 1640, 1780, 1740 1740, 1780 1000|1001: 1700, 1840, 1740 1740, 1840 >=1002: 1740, 1880, 1740 1740, 1880 ///////////////////////// 998 HV: 1640, 1780, 1740. 1740, 1780. Only one spill. Stop to view event 999 1000 HV: 1700, 1840, 1740. 1740, 1840. Only one spill. Stop to view event 1001 1002 HV: 1740, 1880, 1740. 1740, 1880. Only two spill. Stop to view event 1003 MWPC has one event less than CODA 1004 1005 MWPC has one event more than CODA 1006 1007