Project

General

Profile

Actions

ESB DAQ » History » Revision 13

« Previous | Revision 13/17 (diff) | Next »
Simona Malace, 08/30/2020 12:58 PM


1. ESB DAQ

Computers

simonadaq

clrlpc

CPU : solidesbdaq

VTP : esbvtp 129.57.36.253

VXS crate : esbvxs

2. FADC cabling

Slot 3 : Chan 0-7 : Cer14-5,13-4,13-3,13-2,13-1,13-5,12-4,12-3
Slot 3 : Chan 8-15 : Cer12-2,12-1,12-5,11-4,11-3,11-2,11-1,11-5

Slot 4 : Chan 0-7 : Cer 33-1,33-5,23-4,23-3,23-2,23-1,23-5,24-4
Slot 4 : Chan 8-15 : Cer 24-3,24-2,24-1,24-5,14-4,14-3,14-2,14-1

Slot 5 : Chan 0-7 : Cer 43-2,43-1,43-5,44-4,44-3,44-2,44-1,44-5
Slot 5 : Chan 8-15 : Cer 34-4,34-3,34-2,34-1,34-5,33-4,33-3,33-2

Slot 6 : Chan 0-7 : Cer 31-3,31-2,31-1,31-5,41-4,41-3,41-2,41-1
Slot 6 : Chan 8-15 : Cer 41-5,42-4,42,-3,42-2,42-1,42-5,43-4,43-3

Slot 7 : Chan 0-7 : C7-4,C7-3,C7-2,C7-1,C6-4,C6-3,C6-2,C6-1
Slot 7 : Chan 8-15 : C5-4,C5-3,C5-2,C5-1,C4,C3,C2,C1

Slot 8 : Chan 0-7 : Cer 22-1,22-5,32-4,32-3,32-2,32-1,32-5,31-4
Slot 8 : Chan 8-15 : C9-4,C9-3,C9-2,C9-1,C8-4,C8-3,C8-2,C8-1

Slot 9 : Chan 0-7 : empty,empty,cer21-4,21-3,21-2,21-1,21-4,22-4
slot 9 : Chan 8-15 : Cer22-3,Cer22-2,S2-11,S2-10,S2-9,S2-8,S2-7,S2-6

Slot 10 : Chan 0-7 : S2-5,S2-4,S2-3,S2-2,S2-1,S1-11,S1-10,S1-9
Slot 10 : Chan 8-15 : S1-8,S1-7,S1-6,S1-5,S1-4,S1-3,S1-2,S1-1

3. FADC cabling with the LAPPD box

Slot 3 : Chan 0-7 : LAPPD-B8, LAPPD-B7, LAPPD-B6, LAPPD-B5, LAPPD-B4, LAPPD-B3, LAPPD-B2, LAPPD-B1
Slot 3 : Chan 8-15 : LAPPD-A8, LAPPD-A7, LAPPD-A6, LAPPD-A5, LAPPD-A4, LAPPD-A3, LAPPD-A2, LAPPD-A1


To start coda:
  • VNC server should be running on clrlpc:1
  • To connect: vncviewer clrlpc:1 (account/password is a-compton)
  • Open terminal, run: kcoda, then startcoda
  • Configuration is vtpOnly (To include FADC scalers use vtpScalers)

Readout/trigger configuration files:
  • FADC: clrlpc:/home/a-compton/params/fadc250/solidcer.cnf
  • VTP: clrlpc:/home/a-compton/params/vtp/esbvtp.cnf

------------
FADC250 Pedestal measurement program:
export EXPID=solidcer
a-compton@solidesbdaq
/home/a-compton/src/linuxvme/fadc-HallB/test
./fadc250peds result.txt

-----------
VTP environment variables in ESB :

Zynq> printenv
autoload=no
baudrate=115200
bootargs=console=ttyPS0,115200 ip=::::esbvtp:eth0:dhcp nfsroot=129.57.37.107:/diskless/diskless/ArchLinux/armv7-devel/root uio_pdrv_genirq.of_id=my-uio ro rootwait cma=384MB
bootargs_rw=console=ttyPS0,115200 ip=::::esbvtp:eth0:dhcp nfsroot=129.57.37.107:/diskless/diskless/ArchLinux/armv7-devel/root uio_pdrv_genirq.of_id=my-uio rw rootwait cma=384MB
bootcmd=run $modeboot
bootdelay=3
devicetree_image=devicetree.dtb
devicetree_load_address=0x2000000
ethact=ethernet@e000b000
ethaddr=ce:ba:f0:03:00:a0
fdt_high=0x20000000
fdtcontroladdr=3ffa9e30
gatewayip=129.57.168.1
initrd_high=0x20000000
ipaddr=129.57.168.23
kernel_image=uImage
kernel_load_address=0x2080000
kernel_path=linux-install/ArchLinux-armv71
modeboot=sdboot
netmask=255.255.255.0
sdboot=echo Copying Linux from TFTP server to RAM...; echo Download Kernel; if tftpboot ${kernel_load_address} ${kernel_path}/${kernel_image}; then echo OK; else echo FAILED; reset; fi; echo Download DeviceTree; if tftpbo}
sdboot_no=if mmcinfo; then echo Copying Linux from SD to RAM... && load mmc 0 ${kernel_load_address} ${kernel_image} && load mmc 0 ${devicetree_load_address} ${devicetree_image} && bootm ${kernel_load_address} - ${deviceti
serverip=129.57.37.107
stderr=serial@e0000000
stdin=serial@e0000000
stdout=serial@e0000000
tftpboot_no=echo Copying Linux from tftp server to RAM... &&tftpboot ${kernel_load_address} linux_vtp/${kernel_image} &&tftpboot ${devicetree_load_address} linux_vtp/${devicetree_image} &&bootm ${kernel_load_address} - ${;

Environment size: 1814/131068 bytes

3. Flash ADC scalers

The FADC250 modules have internal scalers. These scalers can be read both during data taking, or when a CODA run is not in progress. Scaler server software has been installed on solidesbdaq so that the scalers can be included in the data stream, read by the getscalers command or displayed with xscalers.

To start the scaler server, type "startscalerserver". To stop the scaler server, type "killscalerserver". These commands can be run on clrlpc or solidesbdaq.

To get a text dump of the scalers, run "getscalers solidesbdaq" from clrlpc or the cdaq account on a Hall C machine. The last line of the output is a counter running at 60 Hz which can be used as a time base to calculate rates.

The command "go_xscaler" will bring up an Xscaler display of the FADC scalers. The mapfile is in /home/a-compton/saw/xscaler/scaler.map on clrlpc.

To include scalers in the data stream, use the vtpScalers configuration instead of vtpOnly.

Updated by Simona Malace about 5 years ago · 13 revisions