Hall C DAQ 2020 » History » Version 14
Mark Jones, 03/21/2020 08:17 AM
1 | 10 | Mark Jones | h1. Overal DAQ info |
---|---|---|---|
2 | 11 | Mark Jones | |
3 | 2 | Alexandre Camsonne | Hosname : |
4 | |||
5 | solidesbdaq : intel CPU |
||
6 | esbvtp : VTP, on portserver telnet 129.57.168.242 2002 |
||
7 | clrlpc : main DAQ computer - run the daq in a-compton account there will be a VNC server on :1 to run the DAQ |
||
8 | 3 | Alexandre Camsonne | esbvxs: VXS crate remote control power, use with a browser to power cycle the crate remotely |
9 | 4 | Alexandre Camsonne | |
10 | 5 | Alexandre Camsonne | DAQ is running in a-compton account on clrlpc:1 ( VNC session 1 ) please run DAQ from there |
11 | 1 | Alexandre Camsonne | |
12 | 6 | Alexandre Camsonne | From any computer in the counting hosue : vncviewer -shared clrlpc:1 |
13 | |||
14 | 8 | Alexandre Camsonne | Use vtpOnly config for data taking |
15 | Use vtpPulser to take a run with random trigger from TI only |
||
16 | 7 | Alexandre Camsonne | |
17 | 6 | Alexandre Camsonne | If DAQ is not running you can start it with the startcoda script. |
18 | |||
19 | 10 | Mark Jones | h1. FADC channel map |
20 | 11 | Mark Jones | |
21 | 13 | Mark Jones | Slot 3 : Chan 0-7 : Cer14-5,13-4,13-3,13-2,13-1,13-5,12-4,12-3 |
22 | 12 | Mark Jones | Slot 3 : Chan 8-15 : Cer12-2,12-1,12-5,11-4,11-3,11-2,11-1,11-5 |
23 | 5 | Alexandre Camsonne | |
24 | 10 | Mark Jones | Slot 4 : Chan 0-7 : Cer 33-1,33-5,23-4,23-3,23-2,23-1,23-5,24-4 |
25 | Slot 4 : Chan 8-15 : Cer 24-3,24-2,24-1,24-5,14-4,14-3,14-2,14-1 |
||
26 | 5 | Alexandre Camsonne | |
27 | 14 | Mark Jones | Slot 5 : Chan 0-7 : empty,43-1,43-5,44-4,44-3,44-2,44-1,44-5 |
28 | 10 | Mark Jones | Slot 5 : Chan 8-15 : Cer 34-4,34-3,34-2,34-1,34-5,33-4,33-3,33-2 |
29 | |||
30 | Slot 6 : Chan 0-7 : Cer 31-3,31-2,31-1,31-5,41-4,41-3,41-2,41-1 |
||
31 | 12 | Mark Jones | Slot 6 : Chan 8-15 : Cer 41-5,42-4,42-3,42-2,42-1,42-5,43-4,43-3 |
32 | 10 | Mark Jones | |
33 | Slot 7 : Chan 0-7 : C7-4,C7-3,C7-2,C7-1,C6-4,C6-3,C6-2,C6-1 |
||
34 | Slot 7 : Chan 8-15 : C5-4,C5-3,C5-2,C5-1,C4,C3,C2,C1 |
||
35 | |||
36 | Slot 8 : Chan 0-7 : Cer 22-1,22-5,32-4,32-3,32-2,32-1,32-5,31-4 |
||
37 | Slot 8 : Chan 8-15 : C9-4,C9-3,C9-2,C9-1,C8-4,C8-3,C8-2,C8-1 |
||
38 | |||
39 | 14 | Mark Jones | Slot 9 : Chan 0-7 : Cer 43-2,empty,cer21-4,21-3,21-2,21-1,21-5,22-4 |
40 | 10 | Mark Jones | slot 9 : Chan 8-15 : Cer22-3,Cer22-2,S2-11,S2-10,S2-9,S2-8,S2-7,S2-6 |
41 | |||
42 | Slot 10 : Chan 0-7 : S2-5,S2-4,S2-3,S2-2,S2-1,S1-11,S1-10,S1-9 |
||
43 | Slot 10 : Chan 8-15 : S1-8,S1-7,S1-6,S1-5,S1-4,S1-3,S1-2,S1-1 |
||
44 | |||
45 | |||
46 | |||
47 | h1. HV info |
||
48 | |||
49 | 4 | Alexandre Camsonne | To access the high voltage controls, do |
50 | |||
51 | telnet hctsv11 2001 |
||
52 | |||
53 | from any counting house computer. |
||
54 | |||
55 | 10 | Mark Jones | h1. Gas controller info |
56 | |||
57 | 4 | Alexandre Camsonne | 2. To access the Omega gas pressure controller, use the command |
58 | |||
59 | 9 | Alexandre Camsonne | go_solidgas |
60 | |||
61 | from the cdaq account on a counting house computer. This will start a VNC session to ccsparew11, the PC with the USB connection to the gas pressure controller. |
||
62 | |||
63 | If the PC is not logged in, do SHIFT-CTRL-ALT-DELETE (or press F8 and select the ctrl-alt-delete menu item). Any JLab account can login. |
||
64 | |||
65 | The software to talk to the Omega controller is “Platinum” and should be an icon on the desktop if it has been installed. It has only been installed for Mark and my accounts. |
||
66 | |||
67 | To install the software on another account, open the file browser and navigate to |
||
68 | |||
69 | C:\Windows\Users\Public\Platinum Firmware…\Platinum_Configureator… |
||