Hall C DAQ 2020 » History » Revision 14
Revision 13 (Mark Jones, 03/20/2020 01:53 PM) → Revision 14/17 (Mark Jones, 03/21/2020 08:17 AM)
h1. Overal DAQ info Hosname : solidesbdaq : intel CPU esbvtp : VTP, on portserver telnet 129.57.168.242 2002 clrlpc : main DAQ computer - run the daq in a-compton account there will be a VNC server on :1 to run the DAQ esbvxs: VXS crate remote control power, use with a browser to power cycle the crate remotely DAQ is running in a-compton account on clrlpc:1 ( VNC session 1 ) please run DAQ from there From any computer in the counting hosue : vncviewer -shared clrlpc:1 Use vtpOnly config for data taking Use vtpPulser to take a run with random trigger from TI only If DAQ is not running you can start it with the startcoda script. h1. FADC channel map Slot 3 : Chan 0-7 : Cer14-5,13-4,13-3,13-2,13-1,13-5,12-4,12-3 Slot 3 : Chan 8-15 : Cer12-2,12-1,12-5,11-4,11-3,11-2,11-1,11-5 Slot 4 : Chan 0-7 : Cer 33-1,33-5,23-4,23-3,23-2,23-1,23-5,24-4 Slot 4 : Chan 8-15 : Cer 24-3,24-2,24-1,24-5,14-4,14-3,14-2,14-1 Slot 5 : Chan 0-7 : empty,43-1,43-5,44-4,44-3,44-2,44-1,44-5 Cer 43-2,43-1,43-5,44-4,44-3,44-2,44-1,44-5 Slot 5 : Chan 8-15 : Cer 34-4,34-3,34-2,34-1,34-5,33-4,33-3,33-2 Slot 6 : Chan 0-7 : Cer 31-3,31-2,31-1,31-5,41-4,41-3,41-2,41-1 Slot 6 : Chan 8-15 : Cer 41-5,42-4,42-3,42-2,42-1,42-5,43-4,43-3 Slot 7 : Chan 0-7 : C7-4,C7-3,C7-2,C7-1,C6-4,C6-3,C6-2,C6-1 Slot 7 : Chan 8-15 : C5-4,C5-3,C5-2,C5-1,C4,C3,C2,C1 Slot 8 : Chan 0-7 : Cer 22-1,22-5,32-4,32-3,32-2,32-1,32-5,31-4 Slot 8 : Chan 8-15 : C9-4,C9-3,C9-2,C9-1,C8-4,C8-3,C8-2,C8-1 Slot 9 : Chan 0-7 : Cer 43-2,empty,cer21-4,21-3,21-2,21-1,21-5,22-4 empty,empty,cer21-4,21-3,21-2,21-1,21-5,22-4 slot 9 : Chan 8-15 : Cer22-3,Cer22-2,S2-11,S2-10,S2-9,S2-8,S2-7,S2-6 Slot 10 : Chan 0-7 : S2-5,S2-4,S2-3,S2-2,S2-1,S1-11,S1-10,S1-9 Slot 10 : Chan 8-15 : S1-8,S1-7,S1-6,S1-5,S1-4,S1-3,S1-2,S1-1 h1. HV info To access the high voltage controls, do telnet hctsv11 2001 from any counting house computer. h1. Gas controller info 2. To access the Omega gas pressure controller, use the command go_solidgas from the cdaq account on a counting house computer. This will start a VNC session to ccsparew11, the PC with the USB connection to the gas pressure controller. If the PC is not logged in, do SHIFT-CTRL-ALT-DELETE (or press F8 and select the ctrl-alt-delete menu item). Any JLab account can login. The software to talk to the Omega controller is “Platinum” and should be an icon on the desktop if it has been installed. It has only been installed for Mark and my accounts. To install the software on another account, open the file browser and navigate to C:\Windows\Users\Public\Platinum Firmware…\Platinum_Configureator… and click the setup icon. This will install the Platinum program on the desktop.