Simona Malace, 09/07/2020 12:30 PM


Run List2 - after the Covid shutdown

Calibration runs in prep for taking data at high rate

Run 185: Pulser run to look at MaPMT vtpPulser

Run 188: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.

Run 189: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.

Run 190: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.

Run 202: cosmic run. Calo preamp. All Hv 1200

Run 205: cosmic run. Calo preamp. All Hv 1200, except 9-1,9-2 HV1100

Run 206: maPMT checks -pulser trigger

Run 207: maPMT checks -pulser trigger

Run 208: maPMT checks -pulser trigger - after taking new PEDs

Run 209: maPMT checks -pulser trigger - after taking new PEDs

Run 210: comsics; triggering on calo only

Run 211: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20

Run 212: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20

Run 213: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 18) instead of 20; increased HV for 44 from 1085 to 1095 V

Run 213: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 19) instead of 20;

Run 215: Calo gain matching (vtpScalers)
everything at 1200 V except for: cal-92 at 1000 V; cal-64 at 1150 V; cal-91 at 1100 V

Run 216: Calo gain matching (vtpScalers)
everything the same as for run 215 except for cal-2 at 1170 V; cal-3 at 1230 V; cal-4 at 1265 V

Run 218: Calo gain matching (vtpScalers)
everything the same as for run 216 except for cal-3 at 1210 V; cal-4 at 1240 V; cal-51 at 1300 V

Run 219: Calo gain matching (vtpScalers)
only cal-4, cal-51 and cal-64 stayed the same as for run 218 everything else changed as follows: cal-52 at +60 V; cal-53 at +60 V; cal-54 at +15 V; cal-61 at +10 V; cal-62 at +110 V; cal-63 at +50 V; cal-71 at +110 V; cal-72 at +70 V; cal-73 at +55V; cal-74 at +80 V; cal81 at +110 V; cal-82 at +65 V; cal-83 at +35 V; cal-84 at +35 V; cal-91 at +90 V; cal-92 at+10 V; cal-93 at +40 V; cal-94 at +80 V

Run 220: Calo gain matching (vtpScalers)
everything stayed the same as for run 219 except for: cal-2 at 1180 V; cal-4 at 1247 V; cal-51 at 1350 V; cal-52 at 1265 V; cal-53 at 1285 V; cal-62 at 1342 V; cal-71 at 1345 V; cal-72 at 1310 V; cal-73 at 1262 V; cal-74 at 1320 V; cal-81 at 1380 V; cal-84 at 1255 V; cal-91 at 1280 V; cal-92 at 1045 V; cal-94 at 1320 V

Run 222: Calo gain matching (vtpScalers)
everything stayed the same as for run 220 except for: cal-1 at 1190 V; cal-3 at 1220 V; cal-51 at 1440 V; cal-52 at 1310 V; cal-53 at 1295 V; cal-61 at 1220 V; cal-62 at 1350 V; cal-63 at 1260 V; cal-64 at 1130 V; cal-71 at 1315 V; cal-72 at 1345 V; cal-73 at 1250 V; cal-74 at 1355 V; cal-81 at 1480 V; cal-82 at 1245 V; cal-83 at 1240 V; cal-84 at 1240 V; cal-91 at 1265 V; cal-93 at 1250 V; cal-94 at 1240 V

Run 223: Calo gain matching (vtpScalers)
everything stayed the same as for run 222 except for: cal-51 at 1400 V; cal-52 at 1285 V; cal-64 at 1140 V; cal-71 at 1330 V; cal-72 at 1335 V; cal-74 1335 V; cal-81 at 1430 V; cal-82 at 1255 V; cal-91 at 1275 V; cal-93 at 1245 V; cal-94 at 1285 V; cal-1 at 1195 V; cal-3 at 1212 V; cal-4 at 1242 V

Run 224: Calo gain matching (vtpScalers)
everything stayed the same as for run 223 except for: cal-91 at 1280 V

Run 225: Calo gain matching (vtpScalers)
everything stayed the same as for run 224 except for: cal-91 at 1300 V

Run 226: Calo gain matching (vtpScalers); changed cal-91 from 1300 V to 1260 V

Run 227: Calo gain matching (vtpScalers); changed cal-91 from 1260 V to 1200 V

Run 229: Calo gain matching (vtpScalers); changed cal-91 from 1200 V to 1150 V

Run 230: Calo gain matching (vtpScalers); changed cal-91 from 1150 V to 1170 V

Run 231: Calo gain matching (vtpScalers); changed cal-91 PMT and base; HV for cal-91 at 1250 V

Run 232: Calo gain matching (vtpScalers); nothing changed compared to run 231 just taking more data

Run 233: Calo gain matching (vtpScalers); changed cal-91 from 1250 to 1235 V

Run 239: Calo gain matching overnight run (vtpScalers); coda lost connection with EB when stopped and had to kcoda

vtp Pulser runs for maPMTs checks

Beam data - tune beam

Run 262: beam

Run 263: beam

Run 264: beam; calo TH from 100 to 150 channels - good beam

Run 265: beam;

Run 266: beam;

Run 267: beam;

Run 268: beam;

Run 269: beam;

Run 269: beam; changed cal-94 from 1291 to 1296 V; cal-51 from 1400 to 1404 V; cal-52 from 1285 to 1289 V; cal-53 from 1295 to 1301 V; cal-54 1210 to 1214 V

Run 270: beam;

Run 271: beam; changed cal-51,62,53,64 TH from 150 to 120

Run 271: beam;

Run 272: beam;

Run 273: beam; changed cal-94 HV from 1296 to 1306 V

Run 275: beam; changed maPMT TH from 20 to 200

Run 276: beam; changed maPMT TH back 20

Run 277: beam; vtpPulser with beam

Run 278: beam; vtpScaler - junk, almost no beam

Run 279: evening beam; vtp scalers

Run 280: evening beam; vtp scalers

Run 281: evening beam; vtp scalers; changed the CHER TH from 20 to 10

Run 282: evening beam; vtp scalers; CHER TH back to 20

Run 284: evening beam; vtp scalers;

CW beam

Run 285: CW beam; crappy beam

Run 287: CW beam; a bit better beam

Run 289: CW beam; a bit better beam

Run 290: CW beam; a bit better beam; vtpPulser

Run 291: CW beam; a bit better beam; vtpScaler

Run 292: tune beam; Moller run; all CAL TH at 120 now; crappy beam

Run 293: tune beam

Run 294: CW beam

Run 295: CW beam

Run 296: CW beam

Run 297: mostly tune beam

Run 298: tune + CW beam - vtpPulser; crappy beam; Moller still on

Run 299: tune + CW beam - vtpPulser; crappy beam; Moller still on

Run 300: tune + CW beam - vtpPulser; Moller still on

Run 301: tune + CW beam - vtpPulser; Moller still on

Run 302: CW beam, good beam, vtpScalers, 1 muA on no target

Run 304: junk

Run 305: cosmics

Run 306: junk

Run 307: CW 1 muA "no target"; vtpScalers

Run 308: CW 1 muA "no target"; vtpPulser

Run 309: CW 1.4 muA "no target"; vtpPulser - trippy beam

Run 310: CW 1.4 muA "no target"; vtpPulser - kind of trippy beam

Run 311: CW 1.4 muA "no target"; vtpScaler - trippy beam

Run 312: CW 1.95 muA "no target"; vtpScaler

Run 313: CW 1.95 muA "no target"; vtpPulser

Run 314: CW 0.5 muA "no target"; vtpScalers

LAPPD installation

Run 315: cosmics, calo on; vtpScalers; CALO TH as for beam production

Run 316: cosmics, calo on; vtpScalers; all CALO TH at 100 - junk

Run 317: cosmics, calo on; vtpScalers; all CALO TH at 100 - a bit of beam too :)

Run 318: beam, calo on; vtpScalers; all CALO TH at 120

Run 319: beam, calo on; vtpScalers; all CALO TH at 120

Run 320: beam, calo on; vtpScalers; all CALO TH at 120

Run 321: beam, calo on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo only

Run 322: beam, calo on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo+S2

Run 323: beam, calo on, S2 on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo+S2 - 3He run

Run 324: beam, calo on, S2 on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo+S2 - Ref cell run

Run 325: cosmics; CALO TH at 100; triggering on CALO only

Run 326: troubleshooting S2-5

Run 327: troubleshooting S2-5

Run 328: troubleshooting S2-5

Run 329: troubleshooting S2-5

Run 330: cosmics; calo trigger only; changed CAL-94 from 1306 V to 1320 V

Run 331: beam; calo trigger only;

Run 332: beam; calo trigger only; took fresh PEDs after changing slots 3,4,5,6 in config file - junk, forgot to turn ON the HV after taking PEDs

Run 333: beam; calo trigger only; took fresh PEDs after changing slots 3,4,5,6 in config file -

Run 334: beam; calo trigger only; changed S2-5 from 1380 to 1360 V; S2-2 from 1350 to 1360 V; S2-10 from 1345 to 1360 V; S2-11 from 1380 to 1395 V

Run 335: beam; calo trigger only; changed S2-5 from 1360 to 1375 V;

Run 336: beam; calo trigger only; changed S2-5 from 1375 to 1380 V;

Run 337: cosmics; calo trigger only;

Runs 338-343: junk

Run 344: vtPulser (no beam); LAPPD HV on; TH =10 channels

Run 345: vtPulser (no beam); LAPPD HV on; TH =20 channels

Run 346: vtPulser (no beam); LAPPD HV on; TH =20 channels

Run 347: vtPulser (no beam); LAPPD HV on; TH =20 channels

LAPPD beam

Run 347: vtpScalers (ref cell); LAPPD HV on; TH =20 channels

Run 348: vtpScalers (ref cell); LAPPD HV on; TH =20 channels

Run 349: vtpScalers (ref cell); LAPPD HV on; TH =20 channels

Run 350: vtpScalers (ref cell); LAPPD HV on; TH =70 channels

Run 351: junk

Run 352: vtpScalers (ref cell);; LAPPD HV on; TH =70 channels; CAL TH 200

Run 354: vtpPulser (ref cell);; LAPPD HV on; TH =20 channels; CAL TH 200

Run 355: vtpPulser (no beam);; LAPPD HV on; TH =20 channels; CAL TH 200

LAPPD beam - Sep 05

Run 356: vtpScalers (30 muA beam);; LAPPD HV on; TH =20 channels; CAL TH 120 --> may be junk; CODA was not behaving

Run 357: vtpScalers (30 muA beam);; LAPPD HV on; TH =20 channels; CAL TH 120

Run 360: vtpScalers (30 muA beam);; LAPPD HV on; TH =20 channels; CAL TH 120 -- LAPPD trigger only -- junk

Run 361: vtpScalers (30 muA beam);; LAPPD HV on; TH =10 channels; CAL TH 120

Run 362: vtpScalers (30 muA beam);; LAPPD HV on; TH =5 channels; CAL TH 120

LAPPD beam - Sep 05-06; HV scan

Run 363: vtpScalers (30 muA beam);; LAPPD HV 850+K200; TH =5 channels; CAL TH 120

Run 365: vtpScalers (30 muA beam);; LAPPD HV 850+K100; TH =5 channels; CAL TH 120

Run 366: vtpScalers (30 muA beam);; LAPPD HV 875+K50; TH =5 channels; CAL TH 120

Run 368: vtpScalers (30 muA beam);; LAPPD HV 875+K75; TH =5 channels; CAL TH 120

Run 369: vtpScalers (30 muA beam);; LAPPD HV 875+K100; TH =5 channels; CAL TH 120

Run 370: vtpScalers (30 muA beam);; LAPPD HV 875+K150; TH =5 channels; CAL TH 120

Run 372: vtpScalers (30 muA beam);; LAPPD HV 925/900+K0; TH =5 channels; CAL TH 120

Run 373: vtpScalers (30 muA beam);; LAPPD HV 925/900+K20; TH =5 channels; CAL TH 120

Run 374: vtpScalers (30 muA beam);; LAPPD HV 925/900+K30; TH =5 channels; CAL TH 120; (good)

Run 375: vtpScalers (30 muA beam);; LAPPD HV 925/900+K40; TH =5 channels; CAL TH 120

Run 376: vtpScalers (30 muA beam);; LAPPD HV 925/900+K25; TH =5 channels; CAL TH 120

Run 377: vtpScalers (30 muA beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120; (default, good)

Run 378: vtpScalers (30 muA beam);; LAPPD HV 925/900+K60; TH =5 channels; CAL TH 120

Run 379: vtpScalers (30 muA beam);; LAPPD HV 925/900+K75; TH =5 channels; CAL TH 120

Run 380: vtpScalers (5 muA beam);; LAPPD HV 925/900+K100; TH =5 channels; CAL TH 120; (maybe good?)

Run 381: vtpScalers (30 muA beam);; LAPPD HV 925/900+K100; TH =5 channels; CAL TH 120

Run 382: vtpScalers (30 muA beam);; LAPPD HV 925/913+K75; TH =5 channels; CAL TH 120

Run 383: vtpScalers (30 muA beam);; LAPPD HV 925/913+K60; TH =5 channels; CAL TH 120

Run 384: vtpScalers (30 muA beam);; LAPPD HV 925/913+K50; TH =5 channels; CAL TH 120

Run 385: vtpScalers (30 muA beam);; LAPPD HV 925/913+K40; TH =5 channels; CAL TH 120

Run 386: vtpScalers (30 muA beam);; LAPPD HV 925/913+K30; TH =5 channels; CAL TH 120

Run 387: vtpScalers (30 muA beam);; LAPPD HV 925/913+K20; TH =5 channels; CAL TH 120

Run 388: vtpScalers (30 muA beam);; LAPPD HV 925/913+K0; TH =5 channels; CAL TH 120

Run 389: vtpScalers (30 muA beam);; LAPPD HV 925/925+K0; TH =5 channels; CAL TH 120

Run 390: vtpScalers (30 muA beam);; LAPPD HV 925/925+K20; TH =5 channels; CAL TH 120

Run 391: vtpScalers (30 muA beam);; LAPPD HV 925/925+K30; TH =5 channels; CAL TH 120

Run 393: vtpScalers (30 muA beam);; LAPPD HV 925/925+K40; TH =5 channels; CAL TH 120

Run 394: vtpScalers (30 muA beam);; LAPPD HV 925/925+K50; TH =5 channels; CAL TH 120

Run 395: vtpScalers (30 muA beam);; LAPPD HV 925/925+K60; TH =5 channels; CAL TH 120

Run 396: vtScalers (30 muA beam);; LAPPD HV 925/888+K100; TH =5 channels; CAL TH 120

Run 397: vtScalers (30 muA beam);; LAPPD HV 925/888+K75; TH =5 channels; CAL TH 120

Run 398: vtScalers (30 muA beam);; LAPPD HV 925/888+K60; TH =5 channels; CAL TH 120

Run 399: vtpScalers (30 muA beam);; LAPPD HV 925/888+K50; TH =5 channels; CAL TH 120 (very good)

Run 400: vtpScalers (30 muA beam);; LAPPD HV 925/888+K40; TH =5 channels; CAL TH 120 (good)

Run 402: vtpScalers (30 muA beam);; LAPPD HV 925/888+K30; TH =5 channels; CAL TH 120

Run 403: vtpScalers (30 muA beam);; LAPPD HV 925/888+K20; TH =5 channels; CAL TH 120

Run 405: vtpScalers (30 muA beam);; LAPPD HV 925/888+K0; TH =5 channels; CAL TH 120

Run 406: vtpScalers (30 muA beam);; LAPPD HV 925/875+K0; TH =5 channels; CAL TH 120

Run 407: vtpScalers (30 muA beam);; LAPPD HV 925/875+K20; TH =5 channels; CAL TH 120

Run 408: vtpScalers (30 muA beam);; LAPPD HV 925/875+K30; TH =5 channels; CAL TH 120

Run 409: vtpScalers (30 muA beam);; LAPPD HV 925/875+K40; TH =5 channels; CAL TH 120

Run 410: vtpScalers (30 muA beam);; LAPPD HV 925/875+K50; TH =5 channels; CAL TH 120

Run 411: vtpScalers (30 muA beam);; LAPPD HV 925/875+K50; TH =5 channels; CAL TH 120 (good)

Run 413: vtpScalers (30 muA beam);; LAPPD HV 925/875+K60; TH =5 channels; CAL TH 120

Run 414: vtpScalers (30 muA beam);; LAPPD HV 925/875+K75; TH =5 channels; CAL TH 120

Run 415: vtpScalers (30 muA beam);; LAPPD HV 925/875+K100; TH =5 channels; CAL TH 120

LAPPD beam - Sep 06; Long runs with favorite HV Settings

Run 417: vtpScalers (30 muA beam);; LAPPD HV 925/888+K50; TH =5 channels; CAL TH 120

Run 418: vtpPulser (30 muA beam);; LAPPD HV 925/888+K50; TH =5 channels; CAL TH 120

Run 419: vtpPulser (30 muA beam);; LAPPD HV 925/900+K30; TH =5 channels; CAL TH 120

Run 420: vtpPulser (30 muA beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120

Run 421: vtpPulser (no beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120

Run 422: vtpScalers (30 muA beam);; LAPPD HV 925/900+K30; TH =5 channels; CAL TH 120

Run 423: vtpScalers (30 muA beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120

Run 424: vtpScalers (30 muA beam);; LAPPD HV 925/888+K50; TH =5 channels; CAL TH 120

Run 426: vtpScalers (30 muA beam);; LAPPD HV 925/900+K30; TH =5 channels; CAL TH 120 (last 10 minutes 15uA beam)

Run 427: vtpScalers (30 muA beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120 (many beam trips near the end)

Sep 7

Run 428: vtpScalers (30 muA beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120; trigger LAPPD only

Run 429: vtpScalers (30 muA beam);; LAPPD HV 925/900+K50; TH =5 channels; CAL TH 120; trigger LAPPD+CAL

Run 430: vtpScalers (30 muA beam);; LAPPD HV 925/888+K50; TH =5 channels; CAL TH 120; trigger LAPPD+CAL

Run 431: vtpScalers (30 muA beam);; LAPPD HV 925/900+K30; TH =5 channels; CAL TH 120; trigger LAPPD+CAL

Run List PreCovid

MODE 3 Runs - Nitrogen; all detector channels ON; Cher channels with zero FADC threshold; 3-fold coin

Run 54: short run to test the analyzer

Run 55: done

Run 59: done

MODE 3 Runs - CO2; all detector channels ON - 3-fold coin

Run 63: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero

Run 64: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero

Run 65: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels

Run 66: Same as run 65.

Run 67: adjusted Calorimeter HVs

Run 68: adjusted Calorimeter HVs

MODE 1 Runs - CO2; all detector channels ON - 3-fold coin

Run 69: to test Chao's code

MODE 3 Beam Scintillator Gain matching

Run 113, 114: changed the scin TH from 120 to 160

Run 115, 116: changed the scin TH from 160 to 210

Run 117: changed the scin TH from 210 to 250

Run 132: S2 and Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40

Run 134: Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40

MODE 3 Beam Calorimeter Gain matching

Run 135: Calo HV 4: 1775V, 5-1: 1800, 5-2: 1800, 5-3: 1900, 5-4:1800, 6-2:1800, 7-2:1775, 8-3: 1800, 8-4:1875, 9-1: 1800, 9-4:1850

Run 136: Calo HV 4: 1825V, 5-1: 1850, 5-2: 1850, 5-3: 1950, 5-4:1850, 7-2:18255, 9-2: 1600, 9-4:1900

Run 137: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950

Run 138: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950

Run 139: changed SUM_THR =3 ( SUM_THR is threshold on the CALO trigger)

Run 140: changed SUM_THR =10

Run 141: changed individual calo thresholds from 40 to 80

Run 142: Calo HV 1:1750, 2:1825, 3:1800, 4:1875

Run 143: Add S2 plane to the VTP trigger ( before just calo), changed individual calo thresholds from 80 to 120

Run 144: same as 143

Run 145: same as 143

Run 146: same as 143

Run 147: same as 143

Run 148: changed individual calo thresholds from 120 to 150

Run 149: mistakenly changed calo thresholds 8-1,2,3,4 and 9-1,2,3,4 from 150 to 100

Run 150: changed time window from 768 to 200ns

Run 151: same as 150

Run 152: put calo thresholds 8-1,2,3,4 and 9-1,2,3,4 back to 150, set threshold for 1,2,3,4,5-1,-2,-3,-4 from 150 to 100

MODE 3 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)
Run 153: same as 152

Run 154: same as 152

Run 155: Calo HV 6-1: 1725V, 6-3: 1650V, 7-3: 1800V, 9-2: 1500V

Run 156: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V

Run 157: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V

Run 159: same as 157, steady 30uA on C-OPTICS

Run 161: 30uA on Pol-He3 cell. Use same scaler data as run 160.

MODE 1 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)

Run 158: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run

Run 160: 30uA on PolHe3 target, took scaler rates before this run

Updated by Simona Malace about 5 years ago · 157 revisions