Sylvester Joosten, 03/24/2020 02:40 AM
Run List¶
MODE 3 Runs - Nitrogen; all detector channels ON; Cher channels with zero FADC threshold; 3-fold coin
Run 54: short run to test the analyzer
Run 55: done
Run 59: done
MODE 3 Runs - CO2; all detector channels ON - 3-fold coin
Run 63: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero
Run 64: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero
Run 65: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels
Run 66: Same as run 65.
Run 67: adjusted Calorimeter HVs
Run 68: adjusted Calorimeter HVs
MODE 1 Runs - CO2; all detector channels ON - 3-fold coin
Run 69: to test Chao's code
MODE 3 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)
Run 153
Run 154
Run 157
Run 159: same as 157, steady 30uA on C-OPTICS
Run 161: 30uA on Pol-He3 cell. Use same scaler data as run 160.
MODE 1 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)
Run 158: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run
Run 160: 30uA on PolHe3 target, took scaler rates before this run