Run List » History » Revision 57
Revision 56 (Sylvester Joosten, 07/31/2020 08:14 AM) → Revision 57/176 (Sylvester Joosten, 07/31/2020 08:15 AM)
h1. Run List2 - after the Covid shutdown _*Calibration runs in prep for taking data at high rate*_ _*Run 185*_: Pulser run to look at MaPMT vtpPulser _*Run 188*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers. _*Run 189*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers. _*Run 190*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers. _*Run 202*_: cosmic run. Calo preamp. All Hv 1200 _*Run 205*_: cosmic run. Calo preamp. All Hv 1200, except 9-1,9-2 HV1100 _*Run 206*_: maPMT checks -pulser trigger _*Run 207*_: maPMT checks -pulser trigger _*Run 208*_: maPMT checks -pulser trigger - after taking new PEDs _*Run 209*_: maPMT checks -pulser trigger - after taking new PEDs _*Run 210*_: comsics; triggering on calo only _*Run 211*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20 _*Run 212*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20 _*Run 213*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 18) instead of 20; increased HV for 44 from 1085 to 1095 V _*Run 213*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 19) instead of 20; _*Run 215*_: Calo gain matching (vtpScalers) everything at 1200 V except for: cal-92 at 1000 V; cal-64 at 1150 V; cal-91 at 1100 V _*Run 216*_: Calo gain matching (vtpScalers) everything the same as for run 215 except for cal-2 at 1170 V; cal-3 at 1230 V; cal-4 at 1265 V _*Run 218*_: Calo gain matching (vtpScalers) everything the same as for run 216 except for cal-3 at 1210 V; cal-4 at 1240 V; cal-51 at 1300 V _*Run 219*_: Calo gain matching (vtpScalers) only cal-4, cal-51 and cal-64 stayed the same as for run 218 everything else changed as follows: cal-52 at +60 V; cal-53 at +60 V; cal-54 at +15 V; cal-61 at +10 V; cal-62 at +110 V; cal-63 at +50 V; cal-71 at +110 V; cal-72 at +70 V; cal-73 at +55V; cal-74 at +80 V; cal81 at +110 V; cal-82 at +65 V; cal-83 at +35 V; cal-84 at +35 V; cal-91 at +90 V; cal-92 at+10 V; cal-93 at +40 V; cal-94 at +80 V _*Run 220*_: Calo gain matching (vtpScalers) everything stayed the same as for run 219 except for: cal-2 at 1180 V; cal-4 at 1247 V; cal-51 at 1350 V; cal-52 at 1265 V; cal-53 at 1285 V; cal-62 at 1342 V; cal-71 at 1345 V; cal-72 at 1310 V; cal-73 at 1262 V; cal-74 at 1320 V; cal-81 at 1380 V; cal-84 at 1255 V; cal-91 at 1280 V; cal-92 at 1045 V; cal-94 at 1320 V _*Run 222*_: Calo gain matching (vtpScalers) everything stayed the same as for run 220 except for: cal-1 at 1190 V; cal-3 at 1220 V; cal-51 at 1440 V; cal-52 at 1310 V; cal-53 at 1295 V; cal-61 at 1220 V; cal-62 at 1350 V; cal-63 at 1260 V; cal-64 at 1130 V; cal-71 at 1315 V; cal-72 at 1345 V; cal-73 at 1250 V; cal-74 at 1355 V; cal-81 at 1480 V; cal-82 at 1245 V; cal-83 at 1240 V; cal-84 at 1240 V; cal-91 at 1265 V; cal-93 at 1250 V; cal-94 at 1240 V _*Run 223*_: Calo gain matching (vtpScalers) everything stayed the same as for run 222 except for: cal-51 at 1400 V; cal-52 at 1285 V; cal-64 at 1140 V; cal-71 at 1330 V; cal-72 at 1335 V; cal-74 1335 V; cal-81 at 1430 V; cal-82 at 1255 V; cal-91 at 1275 V; cal-93 at 1245 V; cal-94 at 1285 V; cal-1 at 1195 V; cal-3 at 1212 V; cal-4 at 1242 V _*Run 224*_: Calo gain matching (vtpScalers) everything stayed the same as for run 223 except for: cal-91 at 1280 V _*Run 225*_: Calo gain matching (vtpScalers) everything stayed the same as for run 224 except for: cal-91 at 1300 V _*Run 226*_: Calo gain matching (vtpScalers); changed cal-91 from 1300 V to 1260 V _*Run 227*_: Calo gain matching (vtpScalers); changed cal-91 from 1260 V to 1200 V _*Run 229*_: Calo gain matching (vtpScalers); changed cal-91 from 1200 V to 1150 V _*Run 230*_: Calo gain matching (vtpScalers); changed cal-91 from 1150 V to 1170 V _*Run 231*_: Calo gain matching (vtpScalers); changed cal-91 PMT and base; HV for cal-91 at 1250 V _*Run 232*_: Calo gain matching (vtpScalers); nothing changed compared to run 231 just taking more data _*Run 233*_: Calo gain matching (vtpScalers); changed cal-91 from 1250 to 1235 V _*Run 239*_: 238*_: Calo gain matching overnight run _*vtp Pulser runs for maPMTs checks*_ h2. Run List PreCovid *MODE 3 Runs - Nitrogen; all detector channels ON*; Cher channels with zero FADC threshold; 3-fold coin _*Run 54*_: short run to test the analyzer _*Run 55*_: done _*Run 59*_: done *MODE 3 Runs - CO2; all detector channels ON* - 3-fold coin _*Run 63*_: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero _*Run 64*_: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero _*Run 65*_: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels _*Run 66*_: Same as run 65. _*Run 67*_: adjusted Calorimeter HVs _*Run 68*_: adjusted Calorimeter HVs *MODE 1 Runs - CO2; all detector channels ON* - 3-fold coin _*Run 69*_: to test Chao's code *MODE 3 Beam Scintillator Gain matching* _*Run 113, 114*_: changed the scin TH from 120 to 160 _*Run 115, 116*_: changed the scin TH from 160 to 210 _*Run 117*_: changed the scin TH from 210 to 250 _*Run 132*_: S2 and Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40 _*Run 134*_: Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40 *MODE 3 Beam Calorimeter Gain matching* _*Run 135*_: Calo HV 4: 1775V, 5-1: 1800, 5-2: 1800, 5-3: 1900, 5-4:1800, 6-2:1800, 7-2:1775, 8-3: 1800, 8-4:1875, 9-1: 1800, 9-4:1850 _*Run 136*_: Calo HV 4: 1825V, 5-1: 1850, 5-2: 1850, 5-3: 1950, 5-4:1850, 7-2:18255, 9-2: 1600, 9-4:1900 _*Run 137*_: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950 _*Run 138*_: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950 _*Run 139*_: changed SUM_THR =3 ( SUM_THR is threshold on the CALO trigger) _*Run 140*_: changed SUM_THR =10 _*Run 141*_: changed individual calo thresholds from 40 to 80 _*Run 142*_: Calo HV 1:1750, 2:1825, 3:1800, 4:1875 _*Run 143*_: Add S2 plane to the VTP trigger ( before just calo), changed individual calo thresholds from 80 to 120 _*Run 144*_: same as 143 _*Run 145*_: same as 143 _*Run 146*_: same as 143 _*Run 147*_: same as 143 _*Run 148*_: changed individual calo thresholds from 120 to 150 _*Run 149*_: mistakenly changed calo thresholds 8-1,2,3,4 and 9-1,2,3,4 from 150 to 100 _*Run 150*_: changed time window from 768 to 200ns _*Run 151*_: same as 150 _*Run 152*_: put calo thresholds 8-1,2,3,4 and 9-1,2,3,4 back to 150, set threshold for 1,2,3,4,5-1,-2,-3,-4 from 150 to 100 *MODE 3 Beam golden Runs - CO2; all detector channels ON* - S2 + calo (after calorimeter gain matching) _*Run 153*_: same as 152 _*Run 154*_: same as 152 _*Run 155*_: Calo HV 6-1: 1725V, 6-3: 1650V, 7-3: 1800V, 9-2: 1500V _*Run 156*_: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V _*Run 157*_: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V _*Run 159*_: same as 157, steady 30uA on C-OPTICS _*Run 161*_: 30uA on Pol-He3 cell. Use same scaler data as run 160. *MODE 1 Beam golden Runs - CO2; all detector channels ON* - S2 + calo (after calorimeter gain matching) _*Run 158*_: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run _*Run 160*_: 30uA on PolHe3 target, took scaler rates before this run