Run List » History » Revision 66
Revision 65 (Simona Malace, 08/02/2020 10:38 AM) → Revision 66/176 (Simona Malace, 08/02/2020 10:49 AM)
h1. Run List2 - after the Covid shutdown
_*Calibration runs in prep for taking data at high rate*_
_*Run 185*_: Pulser run to look at MaPMT vtpPulser
_*Run 188*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.
_*Run 189*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.
_*Run 190*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.
_*Run 202*_: cosmic run. Calo preamp. All Hv 1200
_*Run 205*_: cosmic run. Calo preamp. All Hv 1200, except 9-1,9-2 HV1100
_*Run 206*_: maPMT checks -pulser trigger
_*Run 207*_: maPMT checks -pulser trigger
_*Run 208*_: maPMT checks -pulser trigger - after taking new PEDs
_*Run 209*_: maPMT checks -pulser trigger - after taking new PEDs
_*Run 210*_: comsics; triggering on calo only
_*Run 211*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20
_*Run 212*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20
_*Run 213*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 18) instead of 20; increased HV for 44 from 1085 to 1095 V
_*Run 213*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 19) instead of 20;
_*Run 215*_: Calo gain matching (vtpScalers)
everything at 1200 V except for: cal-92 at 1000 V; cal-64 at 1150 V; cal-91 at 1100 V
_*Run 216*_: Calo gain matching (vtpScalers)
everything the same as for run 215 except for cal-2 at 1170 V; cal-3 at 1230 V; cal-4 at 1265 V
_*Run 218*_: Calo gain matching (vtpScalers)
everything the same as for run 216 except for cal-3 at 1210 V; cal-4 at 1240 V; cal-51 at 1300 V
_*Run 219*_: Calo gain matching (vtpScalers)
only cal-4, cal-51 and cal-64 stayed the same as for run 218 everything else changed as follows: cal-52 at +60 V; cal-53 at +60 V; cal-54 at +15 V; cal-61 at +10 V; cal-62 at +110 V; cal-63 at +50 V; cal-71 at +110 V; cal-72 at +70 V; cal-73 at +55V; cal-74 at +80 V; cal81 at +110 V; cal-82 at +65 V; cal-83 at +35 V; cal-84 at +35 V; cal-91 at +90 V; cal-92 at+10 V; cal-93 at +40 V; cal-94 at +80 V
_*Run 220*_: Calo gain matching (vtpScalers)
everything stayed the same as for run 219 except for: cal-2 at 1180 V; cal-4 at 1247 V; cal-51 at 1350 V; cal-52 at 1265 V; cal-53 at 1285 V; cal-62 at 1342 V; cal-71 at 1345 V; cal-72 at 1310 V; cal-73 at 1262 V; cal-74 at 1320 V; cal-81 at 1380 V; cal-84 at 1255 V; cal-91 at 1280 V; cal-92 at 1045 V; cal-94 at 1320 V
_*Run 222*_: Calo gain matching (vtpScalers)
everything stayed the same as for run 220 except for: cal-1 at 1190 V; cal-3 at 1220 V; cal-51 at 1440 V; cal-52 at 1310 V; cal-53 at 1295 V; cal-61 at 1220 V; cal-62 at 1350 V; cal-63 at 1260 V; cal-64 at 1130 V; cal-71 at 1315 V; cal-72 at 1345 V; cal-73 at 1250 V; cal-74 at 1355 V; cal-81 at 1480 V; cal-82 at 1245 V; cal-83 at 1240 V; cal-84 at 1240 V; cal-91 at 1265 V; cal-93 at 1250 V; cal-94 at 1240 V
_*Run 223*_: Calo gain matching (vtpScalers)
everything stayed the same as for run 222 except for: cal-51 at 1400 V; cal-52 at 1285 V; cal-64 at 1140 V; cal-71 at 1330 V; cal-72 at 1335 V; cal-74 1335 V; cal-81 at 1430 V; cal-82 at 1255 V; cal-91 at 1275 V; cal-93 at 1245 V; cal-94 at 1285 V; cal-1 at 1195 V; cal-3 at 1212 V; cal-4 at 1242 V
_*Run 224*_: Calo gain matching (vtpScalers)
everything stayed the same as for run 223 except for: cal-91 at 1280 V
_*Run 225*_: Calo gain matching (vtpScalers)
everything stayed the same as for run 224 except for: cal-91 at 1300 V
_*Run 226*_: Calo gain matching (vtpScalers); changed cal-91 from 1300 V to 1260 V
_*Run 227*_: Calo gain matching (vtpScalers); changed cal-91 from 1260 V to 1200 V
_*Run 229*_: Calo gain matching (vtpScalers); changed cal-91 from 1200 V to 1150 V
_*Run 230*_: Calo gain matching (vtpScalers); changed cal-91 from 1150 V to 1170 V
_*Run 231*_: Calo gain matching (vtpScalers); changed cal-91 PMT and base; HV for cal-91 at 1250 V
_*Run 232*_: Calo gain matching (vtpScalers); nothing changed compared to run 231 just taking more data
_*Run 233*_: Calo gain matching (vtpScalers); changed cal-91 from 1250 to 1235 V
_*Run 239*_: Calo gain matching overnight run (vtpScalers); coda lost connection with EB when stopped and had to kcoda
_*vtp Pulser runs for maPMTs checks*_
Beam data - tune beam
_*Run 262*_: beam
_*Run 263*_: beam
_*Run 264*_: beam; calo TH from 100 to 150 channels - good beam
_*Run 265*_: beam;
_*Run 266*_: beam;
_*Run 267*_: beam;
_*Run 268*_: beam;
_*Run 269*_: beam;
_*Run 269*_: beam; changed cal-94 from 1291 to 1296 V; cal-51 from 1400 to 1404 V; cal-52 from 1285 to 1289 V; cal-53 from 1295 to 1301 V; cal-54 1210 to 1214 V
h2. Run List PreCovid
*MODE 3 Runs - Nitrogen; all detector channels ON*; Cher channels with zero FADC threshold; 3-fold coin
_*Run 54*_: short run to test the analyzer
_*Run 55*_: done
_*Run 59*_: done
*MODE 3 Runs - CO2; all detector channels ON* - 3-fold coin
_*Run 63*_: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero
_*Run 64*_: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero
_*Run 65*_: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels
_*Run 66*_: Same as run 65.
_*Run 67*_: adjusted Calorimeter HVs
_*Run 68*_: adjusted Calorimeter HVs
*MODE 1 Runs - CO2; all detector channels ON* - 3-fold coin
_*Run 69*_: to test Chao's code
*MODE 3 Beam Scintillator Gain matching*
_*Run 113, 114*_: changed the scin TH from 120 to 160
_*Run 115, 116*_: changed the scin TH from 160 to 210
_*Run 117*_: changed the scin TH from 210 to 250
_*Run 132*_: S2 and Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40
_*Run 134*_: Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40
*MODE 3 Beam Calorimeter Gain matching*
_*Run 135*_: Calo HV 4: 1775V, 5-1: 1800, 5-2: 1800, 5-3: 1900, 5-4:1800, 6-2:1800, 7-2:1775, 8-3: 1800, 8-4:1875, 9-1: 1800, 9-4:1850
_*Run 136*_: Calo HV 4: 1825V, 5-1: 1850, 5-2: 1850, 5-3: 1950, 5-4:1850, 7-2:18255, 9-2: 1600, 9-4:1900
_*Run 137*_: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950
_*Run 138*_: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950
_*Run 139*_: changed SUM_THR =3 ( SUM_THR is threshold on the CALO trigger)
_*Run 140*_: changed SUM_THR =10
_*Run 141*_: changed individual calo thresholds from 40 to 80
_*Run 142*_: Calo HV 1:1750, 2:1825, 3:1800, 4:1875
_*Run 143*_: Add S2 plane to the VTP trigger ( before just calo), changed individual calo thresholds from 80 to 120
_*Run 144*_: same as 143
_*Run 145*_: same as 143
_*Run 146*_: same as 143
_*Run 147*_: same as 143
_*Run 148*_: changed individual calo thresholds from 120 to 150
_*Run 149*_: mistakenly changed calo thresholds 8-1,2,3,4 and 9-1,2,3,4 from 150 to 100
_*Run 150*_: changed time window from 768 to 200ns
_*Run 151*_: same as 150
_*Run 152*_: put calo thresholds 8-1,2,3,4 and 9-1,2,3,4 back to 150, set threshold for 1,2,3,4,5-1,-2,-3,-4 from 150 to 100
*MODE 3 Beam golden Runs - CO2; all detector channels ON* - S2 + calo (after calorimeter gain matching)
_*Run 153*_: same as 152
_*Run 154*_: same as 152
_*Run 155*_: Calo HV 6-1: 1725V, 6-3: 1650V, 7-3: 1800V, 9-2: 1500V
_*Run 156*_: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V
_*Run 157*_: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V
_*Run 159*_: same as 157, steady 30uA on C-OPTICS
_*Run 161*_: 30uA on Pol-He3 cell. Use same scaler data as run 160.
*MODE 1 Beam golden Runs - CO2; all detector channels ON* - S2 + calo (after calorimeter gain matching)
_*Run 158*_: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run
_*Run 160*_: 30uA on PolHe3 target, took scaler rates before this run