Simona Malace, 08/02/2020 11:41 AM


Run List2 - after the Covid shutdown

Calibration runs in prep for taking data at high rate

Run 185: Pulser run to look at MaPMT vtpPulser

Run 188: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.

Run 189: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.

Run 190: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers.

Run 202: cosmic run. Calo preamp. All Hv 1200

Run 205: cosmic run. Calo preamp. All Hv 1200, except 9-1,9-2 HV1100

Run 206: maPMT checks -pulser trigger

Run 207: maPMT checks -pulser trigger

Run 208: maPMT checks -pulser trigger - after taking new PEDs

Run 209: maPMT checks -pulser trigger - after taking new PEDs

Run 210: comsics; triggering on calo only

Run 211: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20

Run 212: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20

Run 213: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 18) instead of 20; increased HV for 44 from 1085 to 1095 V

Run 213: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 19) instead of 20;

Run 215: Calo gain matching (vtpScalers)
everything at 1200 V except for: cal-92 at 1000 V; cal-64 at 1150 V; cal-91 at 1100 V

Run 216: Calo gain matching (vtpScalers)
everything the same as for run 215 except for cal-2 at 1170 V; cal-3 at 1230 V; cal-4 at 1265 V

Run 218: Calo gain matching (vtpScalers)
everything the same as for run 216 except for cal-3 at 1210 V; cal-4 at 1240 V; cal-51 at 1300 V

Run 219: Calo gain matching (vtpScalers)
only cal-4, cal-51 and cal-64 stayed the same as for run 218 everything else changed as follows: cal-52 at +60 V; cal-53 at +60 V; cal-54 at +15 V; cal-61 at +10 V; cal-62 at +110 V; cal-63 at +50 V; cal-71 at +110 V; cal-72 at +70 V; cal-73 at +55V; cal-74 at +80 V; cal81 at +110 V; cal-82 at +65 V; cal-83 at +35 V; cal-84 at +35 V; cal-91 at +90 V; cal-92 at+10 V; cal-93 at +40 V; cal-94 at +80 V

Run 220: Calo gain matching (vtpScalers)
everything stayed the same as for run 219 except for: cal-2 at 1180 V; cal-4 at 1247 V; cal-51 at 1350 V; cal-52 at 1265 V; cal-53 at 1285 V; cal-62 at 1342 V; cal-71 at 1345 V; cal-72 at 1310 V; cal-73 at 1262 V; cal-74 at 1320 V; cal-81 at 1380 V; cal-84 at 1255 V; cal-91 at 1280 V; cal-92 at 1045 V; cal-94 at 1320 V

Run 222: Calo gain matching (vtpScalers)
everything stayed the same as for run 220 except for: cal-1 at 1190 V; cal-3 at 1220 V; cal-51 at 1440 V; cal-52 at 1310 V; cal-53 at 1295 V; cal-61 at 1220 V; cal-62 at 1350 V; cal-63 at 1260 V; cal-64 at 1130 V; cal-71 at 1315 V; cal-72 at 1345 V; cal-73 at 1250 V; cal-74 at 1355 V; cal-81 at 1480 V; cal-82 at 1245 V; cal-83 at 1240 V; cal-84 at 1240 V; cal-91 at 1265 V; cal-93 at 1250 V; cal-94 at 1240 V

Run 223: Calo gain matching (vtpScalers)
everything stayed the same as for run 222 except for: cal-51 at 1400 V; cal-52 at 1285 V; cal-64 at 1140 V; cal-71 at 1330 V; cal-72 at 1335 V; cal-74 1335 V; cal-81 at 1430 V; cal-82 at 1255 V; cal-91 at 1275 V; cal-93 at 1245 V; cal-94 at 1285 V; cal-1 at 1195 V; cal-3 at 1212 V; cal-4 at 1242 V

Run 224: Calo gain matching (vtpScalers)
everything stayed the same as for run 223 except for: cal-91 at 1280 V

Run 225: Calo gain matching (vtpScalers)
everything stayed the same as for run 224 except for: cal-91 at 1300 V

Run 226: Calo gain matching (vtpScalers); changed cal-91 from 1300 V to 1260 V

Run 227: Calo gain matching (vtpScalers); changed cal-91 from 1260 V to 1200 V

Run 229: Calo gain matching (vtpScalers); changed cal-91 from 1200 V to 1150 V

Run 230: Calo gain matching (vtpScalers); changed cal-91 from 1150 V to 1170 V

Run 231: Calo gain matching (vtpScalers); changed cal-91 PMT and base; HV for cal-91 at 1250 V

Run 232: Calo gain matching (vtpScalers); nothing changed compared to run 231 just taking more data

Run 233: Calo gain matching (vtpScalers); changed cal-91 from 1250 to 1235 V

Run 239: Calo gain matching overnight run (vtpScalers); coda lost connection with EB when stopped and had to kcoda

vtp Pulser runs for maPMTs checks

Beam data - tune beam

Run 262: beam

Run 263: beam

Run 264: beam; calo TH from 100 to 150 channels - good beam

Run 265: beam;

Run 266: beam;

Run 267: beam;

Run 268: beam;

Run 269: beam;

Run 269: beam; changed cal-94 from 1291 to 1296 V; cal-51 from 1400 to 1404 V; cal-52 from 1285 to 1289 V; cal-53 from 1295 to 1301 V; cal-54 1210 to 1214 V

Run 270: beam;

Run 271: beam; changed cal-51,62,53,64 TH from 150 to 120

Run 271: beam;

Run 272: beam;

Run 273: beam; changed cal-94 HV from 1296 to 1306 V

Run List PreCovid

MODE 3 Runs - Nitrogen; all detector channels ON; Cher channels with zero FADC threshold; 3-fold coin

Run 54: short run to test the analyzer

Run 55: done

Run 59: done

MODE 3 Runs - CO2; all detector channels ON - 3-fold coin

Run 63: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero

Run 64: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero

Run 65: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels

Run 66: Same as run 65.

Run 67: adjusted Calorimeter HVs

Run 68: adjusted Calorimeter HVs

MODE 1 Runs - CO2; all detector channels ON - 3-fold coin

Run 69: to test Chao's code

MODE 3 Beam Scintillator Gain matching

Run 113, 114: changed the scin TH from 120 to 160

Run 115, 116: changed the scin TH from 160 to 210

Run 117: changed the scin TH from 210 to 250

Run 132: S2 and Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40

Run 134: Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40

MODE 3 Beam Calorimeter Gain matching

Run 135: Calo HV 4: 1775V, 5-1: 1800, 5-2: 1800, 5-3: 1900, 5-4:1800, 6-2:1800, 7-2:1775, 8-3: 1800, 8-4:1875, 9-1: 1800, 9-4:1850

Run 136: Calo HV 4: 1825V, 5-1: 1850, 5-2: 1850, 5-3: 1950, 5-4:1850, 7-2:18255, 9-2: 1600, 9-4:1900

Run 137: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950

Run 138: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950

Run 139: changed SUM_THR =3 ( SUM_THR is threshold on the CALO trigger)

Run 140: changed SUM_THR =10

Run 141: changed individual calo thresholds from 40 to 80

Run 142: Calo HV 1:1750, 2:1825, 3:1800, 4:1875

Run 143: Add S2 plane to the VTP trigger ( before just calo), changed individual calo thresholds from 80 to 120

Run 144: same as 143

Run 145: same as 143

Run 146: same as 143

Run 147: same as 143

Run 148: changed individual calo thresholds from 120 to 150

Run 149: mistakenly changed calo thresholds 8-1,2,3,4 and 9-1,2,3,4 from 150 to 100

Run 150: changed time window from 768 to 200ns

Run 151: same as 150

Run 152: put calo thresholds 8-1,2,3,4 and 9-1,2,3,4 back to 150, set threshold for 1,2,3,4,5-1,-2,-3,-4 from 150 to 100

MODE 3 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)
Run 153: same as 152

Run 154: same as 152

Run 155: Calo HV 6-1: 1725V, 6-3: 1650V, 7-3: 1800V, 9-2: 1500V

Run 156: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V

Run 157: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V

Run 159: same as 157, steady 30uA on C-OPTICS

Run 161: 30uA on Pol-He3 cell. Use same scaler data as run 160.

MODE 1 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)

Run 158: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run

Run 160: 30uA on PolHe3 target, took scaler rates before this run

Updated by Simona Malace about 5 years ago · 68 revisions