Wiki » History » Revision 2
Revision 1 (Alexandre Camsonne, 03/07/2019 11:58 AM) → Revision 2/47 (Alexandre Camsonne, 03/07/2019 12:07 PM)
h1. Wiki h1. DAQ DAQ is running on simonadaq computer in coda account in the vnc session number 1. To open VNC, either start VNC from a computer at the counting house through ssh or make a ssh tunnel if you are offsite Example : ssh -L5901:locahost:34567 username@hallgw.jlab.org ( use a port number not in used on hallgw ) after from hallgw ssh -L34567:localhost:5901 cdaq@simonadaq then open a vnc locally on your computer : vncviewer -shared localhost:1 ( ask Junqi or Sylvester for the vnc password ) To start CODA from scratch, login as coda type startcoda that will open the CODA windows in Run Control GUI, go to platform and connect. Then choose the FADC configuration and just start a run. To change the FADC parameters, ssh to hallcsc-1 as root go to /root/linuxvme/fadc/rol and edit fadc_list.c once done compile with : make fadc_list.so and redownload in CODA to take the changes into account rc h1. FADC data analysis on cdaq account go to /home/cdaq/tlgc/FADC_decode and run FADCcom program you need to copy the CODA file from simonadaq to /net/cdaq/cdaql1data/cdaq/tlgc/data ( from simonadaq : scp fadc_runnumber.dat cdaq@cdaql2:tlgc/data/ ) if you open the rootfile you will see the different directories corresponding to the channels decoded.