Project

General

Profile

Bug #1030

Updated by Julie Roche 7 months ago

Loop 3 produce 5% more yield at 30 psia than at 25 psia: https://logbooks.jlab.org/entry/4296639 and https://logbooks.jlab.org/entry/4296687 

 Loop 3 gives us more yields than Loop 2 at 11 uA for 58 and 42 Hz:    https://logbooks.jlab.org/entry/4294810 
 No beam current dependence for Loop2 and Loop3    at 58 Hz: https://logbooks.jlab.org/entry/4295103. This feature is also seen in the target boiling data we took back in Sept 2023: https://redmine.jlab.org/issues/845#change-2067  


 Loop 2 - The issue is not an effect of the controller - https://logbooks.jlab.org/entry/4294867 
 Loop 2 - The issue subsides some when the fan is reversed, but running the fan reversed is unsustainable https://logbooks.jlab.org/entry/4292236 

 Loop2    yield decreases when fan speed increases    https://logbooks.jlab.org/entry/4289172. 
 
 ===== 
 Comparison to DIS simulation: with the most had-hoc tuning of Loop3 we get 75% of expected DIS rates on LH2 (95% on LD2, loop 1). https://logbooks.jlab.org/entry/4297882 

 
 

 ====== 
 Loop2 target cell wall:  
 data taken during vaporisation https://logbooks.jlab.org/entry/4293900 

 ====== 
 There might be a constant ztarget shape difference between LH2 and LD2 throughout the NPS data taking: https://logbooks.jlab.org/entry/4293600. 

 ===== 
 Loop 2 comparison to DIS simulation (see attached plot) 
 x_60_2     Beginning of December 2023 (no dummy target data for PS4) 
 x_60_4     Beginning of February 2024 (dummy target data for PS4 data)  


 ====== 
 Loop2 target cell wall:  
 data taken during vaporisation https://logbooks.jlab.org/entry/4293900 

Back