1 | 1 | Richard Trotta | h1. EDTM |
---|---|---|---|
2 | |||
3 | h2. EDTM Checks |
||
4 | |||
5 | * Change Poisson rate to desired value on pulse generator (check GUI for rate change by using go_prescale_SHMS) |
||
6 | * Take runs at desired prescales individually |
||
7 | ** PS1 = SHMS 3/4 |
||
8 | ** PS2 = SHMS el_real |
||
9 | ** PS3 = HMS el_real |
||
10 | ** PS4 = HMS 3/4 |
||
11 | ** PS5 = SHMS 3/4 & HMS el_real |
||
12 | ** PS6 = SHMS 3/4 & HMS 3/4 |
||
13 | * Once run is taken... |
||
14 | ## ./hcana ~/SCRIPTS/../SCALER/<scaler script>.C |
||
15 | ## input run number |
||
16 | ## check report file (~/hallc_replay/REPORT_OUTPUT/.../SCALER/<reportreplay>.report) |
||
17 | ## check computer livetime for ROC2 |
||