Hallc beamtest runlist highrate » History » Version 3
Jixie Zhang, 03/09/2023 12:47 PM
| 1 | 1 | Jixie Zhang | |
|---|---|---|---|
| 2 | --------------------------------------------------- |
||
| 3 | List of HVs: |
||
| 4 | board1, 6kV, 8-ch: |
||
| 5 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 6 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,__1000 |
||
| 7 | |||
| 8 | board2, 2kV, 16-ch: |
||
| 9 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 10 | HV:___1200,_1600,_1650,_0,_____850,____1000,_1600,___________1515,___________1800,___________1730,_____________930,_____________950,_____________850,__1000,__1000,__1000 |
||
| 11 | |||
| 12 | --------------------------------------------------- |
||
| 13 | |||
| 14 | 3944 By Jixie: debug FADC trigger |
||
| 15 | |||
| 16 | 3949 cosmic(6h) and tune beam no target(3h). By Jixie: debug FADC trigger |
||
| 17 | |||
| 18 | 3950 Pedestal. No HV |
||
| 19 | 3951 cosmic, no beam. debug FADC trigger |
||
| 20 | 3952 debug gem ssp |
||
| 21 | 3953 cosmic, no beam. debug FADC trigger |
||
| 22 | 3954 production. 21:16 Jan 11st - 23:14 Jan 11st |
||
| 23 | daq rate = 12.5kHz |
||
| 24 | |||
| 25 | 3955 production. 22:16 Jan 11st - 23:32 Jan 11st |
||
| 26 | daq rate = 12kHz |
||
| 27 | |||
| 28 | |||
| 29 | ==change prescale factors, disable internal pulse trigger for the first 100k events == |
||
| 30 | |||
| 31 | /*Set prescale for each TS#*/ |
||
| 32 | tiSetInputPrescale(1,0); |
||
| 33 | tiSetInputPrescale(2,0); |
||
| 34 | tiSetInputPrescale(3,5); |
||
| 35 | tiSetInputPrescale(4,3); |
||
| 36 | tiSetInputPrescale(5,3); |
||
| 37 | tiSetInputPrescale(6,0); |
||
| 38 | |||
| 39 | ==use hallc_fadc_ssp config== |
||
| 40 | |||
| 41 | 3956 trash. 22:34 Jan 11st |
||
| 42 | tried to use hallc_fadc_ssp config, could not start CODA |
||
| 43 | |||
| 44 | ==use hallc_fadc config== |
||
| 45 | |||
| 46 | 3957 production. 23:37 Jan 11st - 23:45 Jan 11st |
||
| 47 | daq rate = 12.5kHz @ 2uA , this is the maximum of the daq rate for uvasoild2 |
||
| 48 | Threshold: Cer_Sum(30mV), Shower_Sum(10mV),SC_D(Kedi6-Tile,10mv),SC_B(downstream of Shower,10mV) |
||
| 49 | |||
| 50 | |||
| 51 | 3958 production. 23:48 Jan 11st - 00:47 Jan 12th |
||
| 52 | Threshold: Cer_Sum(100mV), Shower_Sum(10mV),SC_D(Kedi6-Tile,10mv),SC_B(downstream of Shower,10mV) |
||
| 53 | |||
| 54 | ==Turn off HVs== |
||
| 55 | |||
| 56 | Jan 12th, 12:30 |
||
| 57 | |||
| 58 | 2 | Jixie Zhang | 3959-3971 Trash, debug daq |
| 59 | 1 | Jixie Zhang | |
| 60 | |||
| 61 | ----------------------------------------------------------------------- |
||
| 62 | ==Turn on HVs, all Cer HVs are changed from 1000V to 950V, Shower_T(SDU#5) lower from 850V to 800V== |
||
| 63 | |||
| 64 | --------------------------------------------------- |
||
| 65 | List of HVs: |
||
| 66 | board1, 6kV, 8-ch: |
||
| 67 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 68 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,__950 |
||
| 69 | |||
| 70 | board2, 2kV, 16-ch: |
||
| 71 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 72 | HV:___1200,_1600,_1650,_0,_____850,____1000,_1600,___________1515,___________1800,___________1730,_____________930,_____________950,_____________800,___950,___950,___950 |
||
| 73 | |||
| 74 | --------------------------------------------------- |
||
| 75 | |||
| 76 | only TS#6 is enabled, PS#(15,15,15,15,15,15,0) |
||
| 77 | Threshold: Cer_Sum(300mV), Shower_Sum(10mV),SC_D(Kedi6-Tile,10mv),SC_B(downstream of Shower,10mV) |
||
| 78 | |||
| 79 | |||
| 80 | Cer_HV = 950V |
||
| 81 | 3972 pulse, no beam. 18:11 Jan 12th - 18:18 Jan 12th, Cer_HV = 950V |
||
| 82 | 3973 pulse, no beam. 18:19 Jan 12th - 18:24 Jan 12th, Cer_HV = 950V |
||
| 83 | 15.5kHz @ no beam, pulse trigger |
||
| 84 | |||
| 85 | Cer_HV = 970V |
||
| 86 | 3974 pulse, no beam. 18:26 Jan 12th - 18:32 Jan 12th, Cer_HV = 970V |
||
| 87 | 3975 pulse, no beam. 18:32 Jan 12th - 18:52 Jan 12th, Cer_HV = 970V |
||
| 88 | |||
| 89 | Cer_HV = 930V |
||
| 90 | 3976 pulse, no beam. 18:54 Jan 12th - 19:01 Jan 12th, Cer_HV = 930V |
||
| 91 | 3977 pulse, no beam. 19:03 Jan 12th - 19:09 Jan 12th, Cer_HV = 930V |
||
| 92 | |||
| 93 | Cer_HV = 1000V |
||
| 94 | 3978 pulse, no beam. 19:54 Jan 12th - 20:06 Jan 12th, Cer_HV = 1000V |
||
| 95 | 3979 pulse, no beam. 20:06 Jan 12th - 20:16 Jan 12th, Cer_HV = 1000V |
||
| 96 | |||
| 97 | Cer_HV = 1050V |
||
| 98 | 3980 pulse, no beam. 20:17 Jan 12th - 20:24 Jan 12th, Cer_HV = 1050V |
||
| 99 | 3981 pulse, no beam. 20:25 Jan 12th - 20:39 Jan 12th, Cer_HV = 1050V |
||
| 100 | ----------------------------------------------------------------------- |
||
| 101 | |||
| 102 | 3982 cosmic production, |
||
| 103 | first 100k is pulse trigger, 22:36 - 23:28 Jan 12th |
||
| 104 | debug TS#6, all trigger bits enabled, PS#(0,0,0,0,0,0,0) |
||
| 105 | Threshold: Cer_Sum(300mV), Shower_Sum(10mV),SC_D(Kedi6-Tile,10mv),SC_B(downstream of Shower,10mV) |
||
| 106 | |||
| 107 | |||
| 108 | ==cosmic test for Shower only, HVs for others are off, first 100k is pulse trigger== |
||
| 109 | TS#4 only PS#(15,15,15,0,15,15) |
||
| 110 | Threshold: Cer_Sum(300mV), Shower_Sum(10mV),SC_D(Kedi6-Tile,10mv),SC_B(downstream of Shower,10mV) |
||
| 111 | |||
| 112 | 3983 cosmic production, 23:34 - 00:25 Jan 13th |
||
| 113 | Name:_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5) |
||
| 114 | HV:_______________930,_____________950,_____________800 |
||
| 115 | |||
| 116 | ==00:27 Jan 13th, turn all HVs off== |
||
| 117 | |||
| 118 | 3984 cosmic production, 08:25 Jan 13th - 13:03 Jan 13th |
||
| 119 | Name:_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5) |
||
| 120 | HV:______________1030,____________1050,_____________850 |
||
| 121 | |||
| 122 | 3985 cosmic production, 13:04 Jan 13th - 17:13 Jan 13th |
||
| 123 | Name:_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5) |
||
| 124 | HV:______________1030,____________1050,_____________850 |
||
| 125 | see 12 minutes of beam ... detectors are fully saturated |
||
| 126 | |||
| 127 | 3986 cosmic production, 17:13 Jan 13th - 18:32 Jan 13th |
||
| 128 | Name:_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5) |
||
| 129 | HV:______________1030,____________1050,_____________850 |
||
| 130 | see 5 minutes of beam ... detectors are fully saturated |
||
| 131 | |||
| 132 | ==all HVs are off== |
||
| 133 | all 6 trigger bits are on, no prescale factors |
||
| 134 | |||
| 135 | ==dark current run (beam on but HV off, pulse trigger)== |
||
| 136 | 3987 cosmic production, 18:36 Jan 13th - 18:42 Jan 13th |
||
| 137 | I tried to get beam on data, but beam is off |
||
| 138 | |||
| 139 | |||
| 140 | 3988 dark current run, 11:05 Jan 14th - 11:11 Jan 14th |
||
| 141 | beam current 40uA, HV off, pulse trigger |
||
| 142 | |||
| 143 | 3989 dark current run, 11:12 Jan 14th - 11:20 Jan 14th |
||
| 144 | beam current 40uA, HV off, pulse trigger |
||
| 145 | |||
| 146 | ======================================================================= |
||
| 147 | ==5uA to test the prescale factors== |
||
| 148 | HV for CerD is off (forgot to turn on) |
||
| 149 | |||
| 150 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 151 | HV:___1200,_1600,_1650,_0,_____850,____1000,_1600,___________1515,___________1800,___________1730,____________1030,_____________1050,____________850,___950,___950,___950 |
||
| 152 | |||
| 153 | |||
| 154 | 3990 all PS=0 TS1-6 daq rate=15.5kHz |
||
| 155 | 3991 all PS=0 TS1-6 daq rate=15.5kHz |
||
| 156 | 3992 PS4=5, TS1-6 daq rate=15.5kHz |
||
| 157 | 3993 TS4 only PS4=5 daq rate=12.5kHz |
||
| 158 | |||
| 159 | ======================================================================= |
||
| 160 | Increase shower_T HV from 850 to 900 |
||
| 161 | Decrease shower_R HV from 1050 to 1030 |
||
| 162 | HVs for SC_D, SC_A, LASPD_T,LASPD_B, PreSh_# were all got lower |
||
| 163 | |||
| 164 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 165 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,____________1030,_____________1030,____________900,___930,___930,___930 |
||
| 166 | |||
| 167 | CerD HV is also 930V |
||
| 168 | |||
| 169 | 3994-3995 trash, HV boardB tripped |
||
| 170 | |||
| 171 | 3996 dark current run, beam off, HVs all on, pulse trigger, 930V |
||
| 172 | 3997 dark current run, beam off, HVs all on, pulse trigger, 930V |
||
| 173 | |||
| 174 | 3998 dark current run, beam off, HVs all on, pulse trigger, 940V |
||
| 175 | 3999 dark current run, beam off, HVs all on, pulse trigger, 940V |
||
| 176 | |||
| 177 | 4000 dark current run, beam off, HVs all on, pulse trigger, 920V |
||
| 178 | 4001 dark current run, beam off, HVs all on, pulse trigger, 920V |
||
| 179 | |||
| 180 | 4002 dark current run, beam off, HVs all on, pulse trigger, 910V |
||
| 181 | 4003 dark current run, beam off, HVs all on, pulse trigger, 910V |
||
| 182 | |||
| 183 | 4004 dark current run, beam off, HVs all on, pulse trigger, 950V |
||
| 184 | 4005 dark current run, beam off, HVs all on, pulse trigger, 950V |
||
| 185 | |||
| 186 | 4006 dark current run, beam off, HVs all on, pulse trigger, 900V |
||
| 187 | 4007 dark current run, beam off, HVs all on, pulse trigger, 900V |
||
| 188 | |||
| 189 | 4008 dark current run, beam off, HVs all on, pulse trigger, 960V |
||
| 190 | 4009 dark current run, beam off, HVs all on, pulse trigger, 960V |
||
| 191 | |||
| 192 | |||
| 193 | ==================================================================== |
||
| 194 | Cer HVs go back to 950V, 1uA CW beam on He3 target |
||
| 195 | |||
| 196 | 4010 beam on, but only pulse trigger |
||
| 197 | 4011 first 100k is pulse trigger, 50Hz rate without beam. TS1 to 6 are all on, PS4=5; NO real beam on this run |
||
| 198 | 2 | Jixie Zhang | 4012 disabled pulse trigger. All TS#. PS4=5, no beam |
| 199 | 1 | Jixie Zhang | 4013 disabled pulse trigger. All TS#. PS4=9, daq rate = 13.5kHz,1uA beam |
| 200 | 4014 disabled pulse trigger. All TS#. PS4=11, daq rate = 13.5kHz,1uA beam |
||
| 201 | 4015 disabled pulse trigger. All TS#. PS4=15, PS5=15, daq rate = 13.5kHz,1uA beam |
||
| 202 | 4016 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS1=PS2=PS3=PS6=0, daq rate = 13.5kHz, 1uA beam |
||
| 203 | 4017 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS1=PS3=PS6=15, PS2=5, no beam |
||
| 204 | 4018 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS1=PS3=PS6=15, PS2=5, 2uA beam. 12.8KHz |
||
| 205 | 4019 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS1=PS3=PS6=15, PS2=10, 2uA beam. 8.5KHz |
||
| 206 | 4020 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS1=PS3=PS6=15, PS2=12, 2uA beam. 2.7KHz |
||
| 207 | 4021 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS3=PS6=15, PS1=0,PS2=12, 2uA beam. 11KHz |
||
| 208 | 4022 disabled pulse trigger. only TS1,TS2,TS3,TS6 enabled, PS3=PS6=15, PS1=5,PS2=12, 1.8uA beam. 5.7KHz |
||
| 209 | |||
| 210 | Conclusion: on He3 target, PS1=5 will have 1.8kHz/uA for TS#1, PS2=12 will have 1.4kHz/uA for TS#2. |
||
| 211 | We still need to determine PS for PS4 and PS5. |
||
| 212 | After analyze run 4022, I found that for PS3=15, TS#3 has 28Hz/2uA. For PS6=15, TS#6 has 8Hz/2uA. Scaling PS from |
||
| 213 | 15 to 10, we got TS#3 rate as 450Hz/uA and TS#6 rate 130Hz/uA. |
||
| 214 | |||
| 215 | |||
| 216 | =================================================== |
||
| 217 | 2 | Jixie Zhang | 20230120 pedestal runs, beam off, pulse trigger, HV scan |
| 218 | 1 | Jixie Zhang | |
| 219 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 220 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,____________1030,_____________1030,____________900,___930,___930,___930 |
||
| 221 | |||
| 222 | For Cherenkov: ch13,ch14,ch15, E08C2_ch07: 910, 930, 950, 970 |
||
| 223 | For Shower: ch10,ch11: 900, 950, 1000, 1050 |
||
| 224 | For Shower: ch12: 800, 850, 900, 950 |
||
| 225 | |||
| 226 | ch 10 11 12 13 14 15 07 |
||
| 227 | 4023, 4024: HV(ch10-15,E08C2_ch07) : 800, 900, 900, 910, 910, 910, 910 |
||
| 228 | 4025, 4026: 950, 950, 850, 930, 930, 930, 930 |
||
| 229 | 4027, 4028: 1000,1000, 900, 950, 950, 950, 950 |
||
| 230 | 4029, 4030: 1050,1050, 950, 970, 970, 970, 970 |
||
| 231 | 4031, 4032: 1030,1030, 900, 950, 950, 950, 950 |
||
| 232 | |||
| 233 | =================================================== |
||
| 234 | |||
| 235 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 236 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,____________1030,_____________1030,____________900,___930,___930,___930 |
||
| 237 | |||
| 238 | ==turn on FADC threshold to remove no pulse events == |
||
| 239 | slot 7: FADC250_ALLCH_TET 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 |
||
| 240 | slot 8: FADC250_ALLCH_TET 10 10 10 20 10 10 10 5 5 5 5 5 5 15 15 25 |
||
| 241 | |||
| 242 | 4033 debug FADC config, no beam, HV on. 5M pulse trigger |
||
| 243 | 4034 debug FADC config, no beam, HV on. 5M pulse trigger |
||
| 244 | |||
| 245 | ==turn on slot 8 FADC threshold to remove no pulse events == |
||
| 246 | slot 7: FADC250_ALLCH_TET 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 |
||
| 247 | slot 8: FADC250_ALLCH_TET 10 10 10 20 10 10 10 10 10 10 10 10 10 20 20 25 |
||
| 248 | 4035 trash |
||
| 249 | 4036 debug FADC config, no beam, HV on. 5M pulse trigger |
||
| 250 | |||
| 251 | ============== |
||
| 252 | 4037 disabled pulse trigger, cosmic only, beam off HV on |
||
| 253 | |||
| 254 | ============== |
||
| 255 | 2 | Jixie Zhang | 4038-4040 trash, check daq, adjust threshold |
| 256 | 1 | Jixie Zhang | |
| 257 | ======================================================== |
||
| 258 | ==20230123 threshold== |
||
| 259 | Threshold is applied to the height of the waveform: |
||
| 260 | TS1: CerSum(200mv or 410 adc unit) & ShowerSum(70mv or 143 adc unit); |
||
| 261 | TS2: SC_D(20mv or 164 adc unit) & ShowerSum(70mv or 143 adc unit) & SC_B(15mv or 123 adc unit). |
||
| 262 | TS3: 2 out of these 3 inputs: CerSum(200mv or 410 adc unit), ShowerSum(50mv or 103 adc unit), SC_D(20mv or 164 adc unit); |
||
| 263 | TS4: ShowerSum(100mv or 205 adc unit) |
||
| 264 | TS5: SC_B(20mv or 164 adc unit). |
||
| 265 | TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual input |
||
| 266 | |||
| 267 | 5uA tune beam on LHe4, |
||
| 268 | 4041 5uA tune beam on LHe4, PS=10,10,10,10,10,10, rate=250Hz |
||
| 269 | 4042 5uA tune beam on LHe4, PS=4,4,3,1,0,0, rate=2.4kHz |
||
| 270 | 4043 5uA tune beam on LHe4, PS=3,3,2,0,0,0, rate=4kHz |
||
| 271 | |||
| 272 | 2uA CW beam on LHe4, |
||
| 273 | 4044 all TS1-6; PS=7,7,5,5,3,0, 11.5kHz, daq saturated |
||
| 274 | 4045 all TS1-6; PS=8,8,5,3,4,0, 11.2kHz, daq saturated |
||
| 275 | 4046 all TS1-6; PS=8,8,5,3,3,1, 11.2kHz, daq saturated |
||
| 276 | 2 | Jixie Zhang | 4047 all TS1-6; PS=9,9,5,3,3,0, 11.2kHz, daq saturated |
| 277 | 1 | Jixie Zhang | |
| 278 | 2uA CW beanm on LHe4, |
||
| 279 | 4048 TS#4 only, PS4=3, rate=10.0kHz |
||
| 280 | 4049-4050 trash |
||
| 281 | 4051 TS#4 only, PS4=4, rate=5.9kHz |
||
| 282 | 4052-4054 trash, TS#5 only, no rate, TS#5 cable connection might have problem |
||
| 283 | 4055 TS#4 only, PS4=4, rate=5.6kHz |
||
| 284 | ==turn off sw test pulse in diaggui, this test inserts 100Hz pulse into FADC== |
||
| 285 | ==do not know how it affects the above data== |
||
| 286 | 4056 trash, TS#6 only, no rate, |
||
| 287 | 4057 TS#3 only, PS3=5, rate=2.0kHz |
||
| 288 | 4058 TS#3 only, PS3=3, rate=6.8kHz |
||
| 289 | 4059 trash |
||
| 290 | 4060 TS#2 only, PS2=10, rate=1.1kHz |
||
| 291 | 4061 TS#2 only, PS2= 7, rate=7.6kHz |
||
| 292 | 2 | Jixie Zhang | 4062 TS#1 only, PS1= 9, rate=2.8kHz |
| 293 | 4063 TS#1 only, PS1= 7, rate=9.2kHz |
||
| 294 | 1 | Jixie Zhang | 4064 All TS, PS=9,9,5,6,6,1, rate=7.8kHz, |
| 295 | |||
| 296 | 4065 All TS, PS=9,9,5,6,6,1, 20uA beam on LHe4, rate=11.2kHz, daq saturated |
||
| 297 | |||
| 298 | ======================================================== |
||
| 299 | 2 | Jixie Zhang | 4066 pedestal verification, beam off, HV off, pulse trigger, 500k |
| 300 | |||
| 301 | |||
| 302 | ------------------------------------------------------------------------ |
||
| 303 | ToFix: |
||
| 304 | Jimmy reported that the level1 tree has bug that some variables (cer[16]) are still |
||
| 305 | keeping the value of previous event if there is no hit in current event. (run4015) |
||
| 306 | ------------------------------------------------------------------------ |
||
| 307 | |||
| 308 | |||
| 309 | Mistakes for runs from 3972 to 4066 |
||
| 310 | 1. The vmeDSC has positive pulse output if one follows the +|- label. NIM logic board expects |
||
| 311 | negative pulse inputs. Therefore our TS#1,TS#2 and TS#3 in run 3972-4066 are not what we designed. |
||
| 312 | TS#1 and TS#2 are logical "OR". TS#3 is complicated to express. |
||
| 313 | |||
| 314 | Mistakes for runs between 4023 and 4066: |
||
| 315 | 1. TS#4 is actually triggered by SC_B due to cable wrongly shift by 1 pin. |
||
| 316 | On Jan 20 I tried to move TS#4(vmeDSC_ch12) and TS#5(vmeDSC_ch11) to vmeDSC_ch14 and vmeDSC_ch15. |
||
| 317 | But they are actually shifted by one pin location, which are vmeDSC_ch15 and vmeDSC_ch16. |
||
| 318 | Due to this mistake, trigger-bit 4 (0x1000) is actually triggered by SC_B (the SC behind shower), |
||
| 319 | Runs 4023-4066 are affected. |
||
| 320 | |||
| 321 | ========================================================= |
||
| 322 | 20230124 |
||
| 323 | Fixed ECL cable invertly connection problem, FADC TrigOut is connected to vmeDSC_ch16, then connecting to TS#6 |
||
| 324 | Verified TS#1-5 using function generator, still need to verify TS#6 from data |
||
| 325 | |||
| 326 | 4067 all TS1-6, no PS, pulse trigger, no beam |
||
| 327 | 4068 all TS1-6, no PS, pulse trigger, no beam |
||
| 328 | 4069 all TS1-6, no PS, cosmic trigger trigger, no beam |
||
| 329 | ==cosmic trigger threshold== |
||
| 330 | Threshold is applied to the height of the waveform: |
||
| 331 | TS1: CerSum(150mv or 307 adc unit) & ShowerSum(30mv or 61 adc unit); |
||
| 332 | TS2: SC_D(20mv or 164 adc unit) & ShowerSum(30mv or 61 adc unit) & SC_B(15mv or 123 adc unit). |
||
| 333 | TS3: 2 out of these 3 inputs: CerSum(150mv or 307 adc unit), ShowerSum(30mv or 61 adc unit), SC_D(20mv or 164 adc unit); |
||
| 334 | TS4: ShowerSum(50mv or 102 adc unit). |
||
| 335 | TS5: SC_B(20mv or 164 adc unit). |
||
| 336 | TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual input |
||
| 337 | |||
| 338 | ========================================================= |
||
| 339 | |||
| 340 | to do: |
||
| 341 | look into run 4055 for Shower_R and SC_A |
||
| 342 | |||
| 343 | Raise TS4 threshold to 700mV and take some runs. |
||
| 344 | For TS4-only run, please adjust PS to keep rate at 3kHz. (If PS is too high, raise the threshold to 800mV or 900mV or 1V). |
||
| 345 | Need dedicated runs for each of TS4,5,1,2,3, in that order, and ideally also one run with all triggers on. |
||
| 346 | |||
| 347 | 4071 40uA beam on Carbon target, TS#4 only, PS=0, only Shower HVs are on. ShowerSum threshold is 85mV, daq rate is 4.5kHz. |
||
| 348 | 4072 40uA beam on Carbon target, TS#5 only, PS=0, only SC_B HV is on. SC_B threshold is 90mV, daq rate is 4.8kHz. |
||
| 349 | 4073 trash |
||
| 350 | 4074 40uA beam on Carbon target, TS#2 only, PS2=5, all HVs are on. threshold: SC_B(15mV),SC_D(20mV),ShowerSum(50mV), daq rate is 7.7kHz. |
||
| 351 | 4075 trash |
||
| 352 | 4076 40uA beam on Carbon target, TS#3 only, PS3=10, all HVs are on. threshold: CerSum(200mV),SC_D(20mV),ShowerSum(50mV), daq rate is 5.5kHz. |
||
| 353 | 4077 40uA beam on Carbon target, TS#1 only, PS1=7, all HVs are on. threshold: CerSum(200mV),ShowerSum(70mV), daq rate is 0.7kHz. |
||
| 354 | 4078 40uA beam on Carbon target, TS#1 only, PS1=4, all HVs are on. threshold: CerSum(200mV),ShowerSum(70mV), daq rate is 4.8kHz. |
||
| 355 | 4079 40uA beam on Carbon target, TS#6 only, PS6=5, all HVs are on. threshold: CerSum(200mV), daq rate is 0Hz. MaPMTs are fully saturated. |
||
| 356 | 4080 40uA beam on Carbon target, TS#5 only, PS=8, only SC_B HV is on. SC_B threshold is 30mV, daq rate is 6.8kHz. |
||
| 357 | |||
| 358 | ==I doubt the signal cable of left and right shower are swapped== |
||
| 359 | 4081 debug daq, only left preshower and left shower on, TS4 only, PS4=1, threshold=85mV |
||
| 360 | 4082 debug daq, only right preshower and right shower on, TS4 only, PS4=1, threshold=85mV |
||
| 361 | 4083 debug daq, only top preshower and top shower on, TS4 only, PS4=1, threshold=85mV |
||
| 362 | |||
| 363 | Result(conclusion): cable connections are all good. |
||
| 364 | |||
| 365 | ========================================================= |
||
| 366 | |||
| 367 | A) What type of input pulse TI expects? |
||
| 368 | The TI we are using expects a positive differential pulse (meaning positive pulse on the + pin, |
||
| 369 | and simultaneously a negative pulse on the - pin). |
||
| 370 | The output of most level translator used in JLab can connect directly to TI, but not any logic unit output. |
||
| 371 | Its manual can be found here: |
||
| 372 | https://coda.jlab.org/drupal/system/files/pdfs/HardwareManual/TI/TI.pdf |
||
| 373 | |||
| 374 | B) can we tell readout to read FADC waveform even though it can not pass the given threshold? |
||
| 375 | |||
| 376 | JLab FADC250 can force all channels to be readout even with a threshold still specified. |
||
| 377 | The flag/mask, FADC250_TET_IGNORE_MASK, tells the readout whether or not to use the threshold (but the trigger will). |
||
| 378 | For example: |
||
| 379 | FADC250_TET_IGNORE_MASK 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 |
||
| 380 | |||
| 381 | to do: |
||
| 382 | 1) Addjust the following thresholds |
||
| 383 | Trig5: SC_B 10mV |
||
| 384 | Trig4: addjust threshold to get 3-4 kHz rate when PS4=0; |
||
| 385 | Trig2: SC_B 10mV, SC_D 10mV, ShowerSum 10mV |
||
| 386 | |||
| 387 | **Trig1 and Trag3 not mentioned in the meeting, should I change ShowerSum for these 2??? |
||
| 388 | |||
| 389 | 2)take dedicated runs for each trigger type in this order : TS4, TS5, TS1, TS2, TS3, TS6 |
||
| 390 | It will take about 45s-60s to change TS configuration. |
||
| 391 | Each run will take about 300k to 400k triggers for 60s of beam time. |
||
| 392 | in total 12 minutes. |
||
| 393 | |||
| 394 | 3)take one run with all triggers on. (2 minutes including TS configuration changing time) |
||
| 395 | |||
| 396 | =================================================================== |
||
| 397 | 20230127 |
||
| 398 | |||
| 399 | 4084 pedestal run. No beam HVs on, Preshower HVs stayed at ___________1470,___________1740,___________1680, |
||
| 400 | 4085 pedestal run. No beam HVs on, Preshower HVs changed back to ______1515,___________1800,___________1730, |
||
| 401 | 4086 pedestal run. No beam HVs off |
||
| 402 | |||
| 403 | 15:11 all HVs on |
||
| 404 | --------------------------------------------------- |
||
| 405 | List of HVs: |
||
| 406 | board1, 6kV, 8-ch: |
||
| 407 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 408 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,___950 |
||
| 409 | |||
| 410 | |||
| 411 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 412 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,____________1030,_____________1030,____________900,___950,___950,___950 |
||
| 413 | |||
| 414 | ==20230127 threshold== |
||
| 415 | Threshold is applied to the height of the waveform: |
||
| 416 | TS1: CerSum(200mv or 410 adc unit) & ShowerSum(70mv or 143 adc unit); |
||
| 417 | TS2: SC_D(10mv or 82 adc unit) & ShowerSum(10mv or 21 adc unit) & SC_B(10mv or 82 adc unit). |
||
| 418 | TS3: 2 out of these 3 inputs: CerSum(200mv or 410 adc unit), ShowerSum(50mv or 103 adc unit), SC_D(10mv or 82 adc unit); |
||
| 419 | TS4: ShowerSum(200mv or 410 adc unit) |
||
| 420 | TS5: SC_B(10mv or 82 adc unit). |
||
| 421 | TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual input |
||
| 422 | |||
| 423 | 2uA cw beam on He3 target |
||
| 424 | |||
| 425 | 4087 TS#4 only, PS4=0, threshold=67mV, daq rate=12kHz, saturated |
||
| 426 | 4088 TS#4 only, PS4=0, threshold=70mV, daq rate=12kHz, saturated |
||
| 427 | 4089 TS#4 only, PS4=0, threshold=75mV, daq rate=12kHz, saturated |
||
| 428 | 4090 TS#4 only, PS4=0, threshold=80mV, daq rate=12kHz, saturated |
||
| 429 | 4091 TS#4 only, PS4=0, threshold=100mV, daq rate=12kHz, saturated |
||
| 430 | 4092 TS#4 only, PS4=0, threshold=200mV, daq rate=12kHz, saturated |
||
| 431 | 4093 TS#4 only, PS4=5, threshold=200mV, daq rate=1.2kHz |
||
| 432 | 4094 TS#4 only, PS4=3, threshold=200mV, daq rate=5kHz |
||
| 433 | 4095 TS#2 only, PS2=10,threshold=SC_D(10mV),SC_B(10mV),ShowerSum(10mV), daq rate=5Hz |
||
| 434 | 4096 TS#2 only, PS2=3, threshold=SC_D(10mV),SC_B(10mV),ShowerSum(10mV), daq rate=550Hz |
||
| 435 | 4097 TS#2 only, PS2=0, threshold=SC_D(10mV),SC_B(10mV),ShowerSum(10mV), daq rate=2.5kHz |
||
| 436 | 4098 TS#1 only, PS1=4, threshold=CerSum(200mV),ShowerSum(50mV), daq rate=3.2kHz |
||
| 437 | 4099 TS#1 only, PS1=2, threshold=CerSum(200mV),ShowerSum(50mV), daq rate=9.5kHz |
||
| 438 | 4100 TS#1 only, PS1=4, threshold=CerSum(200mV),ShowerSum(50mV), daq rate=3.2kHz |
||
| 439 | 4101 TS#1-6 all, PS1-6=4,0,10,4,10,5, daq rate=5.2kHz |
||
| 440 | |||
| 441 | =============================================================================== |
||
| 442 | 4102-4109 debug GEM daq |
||
| 443 | |||
| 444 | --------------------------------------------------- |
||
| 445 | List of HVs: |
||
| 446 | board1, 6kV, 8-ch: |
||
| 447 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 448 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,___950 |
||
| 449 | |||
| 450 | |||
| 451 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 452 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,_____________1030,____________1030,____________900,___950,___950,___950 |
||
| 453 | |||
| 454 | |||
| 455 | 20230201 |
||
| 456 | 1. Chagned GEM gas bottle |
||
| 457 | 2. Connected GEM cables |
||
| 458 | 3. Flipped polarity for the inputs of TS4,TS5,TS6 |
||
| 459 | |||
| 460 | 4110 pedestal run, beam off, HVs off, pulse trigger |
||
| 461 | 4111 pedestal run, beam off, HVs off, pulse trigger |
||
| 462 | 4112 pedestal run, beam off, HVs on, pulse trigger |
||
| 463 | 4113 pedestal run, beam off, HVs on, pulse trigger |
||
| 464 | |||
| 465 | 4114-4118 GEM pedestal run |
||
| 466 | |||
| 467 | 20230203 |
||
| 468 | |||
| 469 | --------------------------------------------------- |
||
| 470 | List of HVs: |
||
| 471 | board1, 6kV, 8-ch: |
||
| 472 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 473 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,___950 |
||
| 474 | |||
| 475 | |||
| 476 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 477 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,_____________900,____________1030,____________1030,___950,___950,___950 |
||
| 478 | |||
| 479 | ==20230203 threshold== |
||
| 480 | Threshold is applied to the height of the waveform: |
||
| 481 | TS1: CerSum(100mv or 205 adc unit) & ShowerSum(150mv or 307 adc unit); |
||
| 482 | TS2: SC_D(5mv or 41 adc unit) & ShowerSum(5mv or 11 adc unit) & SC_B(6mv or 49 adc unit). |
||
| 483 | TS3: disabled |
||
| 484 | TS4: ShowerSum(300mv or 615 adc unit) |
||
| 485 | TS5: SC_B(6mv or 49 adc unit). |
||
| 486 | TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual input |
||
| 487 | |||
| 488 | |||
| 489 | 4019 GEM pedestal run, HV off, 40uA beam on He3 target |
||
| 490 | |||
| 491 | ==2uA CW beam on He3 target== |
||
| 492 | all HVs are on without GEM, hallc_fadc config |
||
| 493 | |||
| 494 | 4120 TS4 only, PS4=3, rate<600Hz |
||
| 495 | 4121 TS4 only, PS4=0, rate=1.2kHz |
||
| 496 | 4122 TS2 only, PS2=0, rate=5.4kHz |
||
| 497 | 4123 TS1 only, PS1=5, rate<25Hz |
||
| 498 | 4124 TS1 only, PS1=0, rate=600Hz |
||
| 499 | 4125 TS1,TS2,TS4,TS5,TS6, PS=0,0,0,10,5, rate=10kHz |
||
| 500 | |||
| 501 | change to hallc_fadc_ssp config |
||
| 502 | 4126 TS1,TS4, PS1=PS4=0, GEM HVs on after starting the run |
||
| 503 | |||
| 504 | ======================================================================== |
||
| 505 | 20230208 |
||
| 506 | |||
| 507 | --------------------------------------------------- |
||
| 508 | List of HVs: |
||
| 509 | board1, 6kV, 8-ch: |
||
| 510 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 511 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,___950 |
||
| 512 | |||
| 513 | |||
| 514 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 515 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,_____________900,____________1030,____________1030,___950,___950,___950 |
||
| 516 | |||
| 517 | GEM HVs are off all the time. |
||
| 518 | use hallc_fadc_ssp config |
||
| 519 | |||
| 520 | 4127-4128 pedestal run, beam off and on, HV off, |
||
| 521 | |||
| 522 | 4129-4130 pedestal run, beam off, HV off, |
||
| 523 | 4131-4132 pedestal run, beam off, HV on, |
||
| 524 | 4133-4134 pedestal run, beam off, HV on, change Shower HVs (L,R,T) from (900,1030,1030) to (900,1100,1000) |
||
| 525 | |||
| 526 | 4135 trash, reboot coda |
||
| 527 | use hallc_fadc config, keep HVs as run 4133, FADC will not record signal below threshold. |
||
| 528 | 4136-4139 pedestal run, no beam, HVs on. 8M events each run |
||
| 529 | 4140 pedestal run, no beam, HVs on. 137M events in this run, 16:00 Feb 8th - 00:05 Feb 9th, |
||
| 530 | beam was back during from 19:02-19:22 (subrun 5-11) and 22:13-00:05 (subrun 17-37) |
||
| 531 | data triggers (TS#6 only) are missed with pulse triggers. The timing of TS#6 is out of scope, |
||
| 532 | therefore these events are all random! |
||
| 533 | |||
| 534 | ======================================================================== |
||
| 535 | ==Escorded access 20230210== |
||
| 536 | 1. HV channel of 2nd GEM (from upstream to downstream) switched from Board A.1 to A.5. |
||
| 537 | A.1 is not stable, sometimes it will not work, sometime do. |
||
| 538 | 2. Reconnected SC_A signal cable |
||
| 539 | 3. Reduced the delay cable length of SC_B by 5 feet, |
||
| 540 | 4. We need to have 5 copies of ShowerSum signal. One go to FADC, four go to vmeDSC. |
||
| 541 | Therefore we need to have an extra FIFO after summing up 3 shower blocks. The copy goes to |
||
| 542 | FADC is coming right after the summing. All four ShowerSum signals used in vmeDSC are from the extra FIFO. |
||
| 543 | This FIFO will have ~10ns delay, which will match to CerSum better. |
||
| 544 | (In the past vmeDSC ch03,ch04,ch05 are all come from summing unit, FADC and vmeDSC ch14 are from the extra FIFO.) |
||
| 545 | |||
| 546 | |||
| 547 | 20230210 |
||
| 548 | 40uA beam on Carbon target,keep Shower HVs (L,R,T) at (900,1100,1000) |
||
| 549 | 4141 pedestal run, beam on, HV off, |
||
| 550 | 4142 TS4 only, PS4=5, threshold 20mv, |
||
| 551 | 4143 TS4 only, PS4=5, threshold 20mv |
||
| 552 | 4144 TS1 only, PS1=5 threshold 200mv & 20mv |
||
| 553 | 4145 TS1 only, PS1=5 threshold 200mv & 20mv |
||
| 554 | 4146 TS5 only, PS5=5, threshold 10mv |
||
| 555 | 4147 TS2 only, PS2=0, threshold 10mv & 20mv & 10mv |
||
| 556 | 4148 TS2 only, PS2=0, threshold 10mv & 20mv & 10mv |
||
| 557 | 4149 TS4 only, PS4=5, threshold 20mv, change Shower HVs (L,R,T) from (900,1100,1000) to (800,1050,900) |
||
| 558 | |||
| 559 | 4150-4151 debug GEM, TS5 only, only GEM and SC_B HVs are on, threshold 40mv, PS5=5 |
||
| 560 | 4152 TS4 only, GEM and all other HVs are on, threshold 200mv, PS4=0. SC_D DAC value set too low |
||
| 561 | |||
| 562 | 4153 trash, no raw data file |
||
| 563 | 4154 TS5 only, PS5=3, all HVs are on without GEM, threshold 60mv |
||
| 564 | 4155 TS6 only, PS6=0, all HVs are on without GEM, 15mv 2/15 Cer individual |
||
| 565 | |||
| 566 | ======================================================================== |
||
| 567 | 20230212 |
||
| 568 | 15:25 10uA CW beam on He3 target |
||
| 569 | --------------------------------------------------- |
||
| 570 | List of HVs: |
||
| 571 | board1, 6kV, 8-ch: |
||
| 572 | Name:_GEM00,_GEM01,_GEM10,_GEM11,__,__,__,_Cer_D |
||
| 573 | HV:_______0,_____0,_____0,_____0,_0,_0,_0,___950 |
||
| 574 | |||
| 575 | |||
| 576 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 577 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,_____________800,____________1050,_____________900,___950,___950,___950 |
||
| 578 | |||
| 579 | |||
| 580 | 4156 TS4 only, PS4=3, all HVs are on without GEM, threshold 200mv, rate=470Hz, 66k events |
||
| 581 | 4157 TS4 only, PS4=3, all HVs are on without GEM, threshold 20mv, rate=12.2kHz, 1.7M events, daq saturated |
||
| 582 | set FADC250_TET_IGNORE_MASK to 0 for slot7 and slot8 |
||
| 583 | 4158 TS4 only, PS4=3, all HVs are on without GEM, threshold 20mv(ShowerSum), rate=13.8kHz, 1.7M events |
||
| 584 | 4159 TS1 only, PS1=3, all HVs are on without GEM, threshold 200mv(CerSum, about 12 pe) & 20mv(ShowerSum), rate=13.8kHz, 1.2M events |
||
| 585 | 4160 TS2 only, PS2=0, all HVs are on without GEM, threshold 10mv(SC_D) & 10mv(ShowerSum) & 40mv(SC_B), rate=200Hz, 16k events |
||
| 586 | 4161 TS2 only, PS2=0, all HVs are on without GEM, threshold 6mv(SC_D) & 10mv(ShowerSum) & 6mv(SC_B), rate=13.2kHz, 2.4M events |
||
| 587 | 4162 TS2 only, PS2=0, all HVs are on without GEM, threshold 10mv(SC_D) & 20mv(ShowerSum) & 10mv(SC_B), rate=12.2kHz, 1.1M events |
||
| 588 | 4163 TS3 only, PS3=5, all HVs are on without GEM, threshold 10mv(SC_D) & 50mv(ShowerSum) & 200mv(CerSum, about 12 pe), rate=6kHz, 1.1M events |
||
| 589 | |||
| 590 | 4164 TS2 only, PS2=1, all HVs are on without GEM, threshold 10mv(SC_D) & 20mv(ShowerSum) & 10mv(SC_B), |
||
| 591 | beam current went up to 25uA, rate=450Hz (detector saturated if beam current>20uA), 26k events |
||
| 592 | |||
| 593 | 16:02 Turn aLL HVs off |
||
| 594 | ===4161 good TS2 hreshold: 5mv(SC_D) & 10mv(ShowerSum) & 6mv(SC_B), rate=13.2kHz, 2.4M events=== |
||
| 595 | |||
| 596 | 20230213 reboot NIM crate and vme crate |
||
| 597 | |||
| 598 | ==20230213 threshold== |
||
| 599 | Threshold is applied to the height of the waveform: |
||
| 600 | TS1: CerSum(50mv or 102 adc unit, about 2.9 pe) & ShowerSum(20mv or 41 adc unit); |
||
| 601 | TS2: SC_D(6mv or 49 adc unit) & ShowerSum(20mv or 41 adc unit) & SC_B(6mv or 49 adc unit). |
||
| 602 | TS3: disabled |
||
| 603 | TS4: ShowerSum(200mv or 405 adc unit) |
||
| 604 | TS5: SC_B(6mv or 49 adc unit). |
||
| 605 | TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit,about 0.8 pe) for each Cherenkov individual input |
||
| 606 | |||
| 607 | |||
| 608 | set FADC250_TET_IGNORE_MASK to 0 for slot7 and slot8 |
||
| 609 | 4165 pedestal run, beam off, HVs on |
||
| 610 | 4166 pedestal run, beam off, HVs on |
||
| 611 | 4167 pedestal run, beam off, HVs off |
||
| 612 | set FADC250_TET_IGNORE_MASK to 1 for slot7 and slot8 |
||
| 613 | 4168 pedestal run, beam off, HVs off |
||
| 614 | 4169 pedestal run, beam off, HVs on |
||
| 615 | |||
| 616 | Carbon target |
||
| 617 | 4170 TS4 only, PS4=0, threshold 200mv, change Shower HVs(L,R,T) from (800,1050,900) to (900,1030,1030), daq rate 100Hz, tune beam |
||
| 618 | 4171 TS4 only, PS4=0, threshold 200mv, HVs(L,R,T) stay at (900,1030,1030), daq rate 5kHz, cw beam < 20uA |
||
| 619 | |||
| 620 | |||
| 621 | ToDo: |
||
| 622 | 2uA CW beam, TS2 only, PS2=0, HV scan at the same threshold as 4122: |
||
| 623 | SC_D(5mv or 41 adc unit) & ShowerSum(5mv or 11 adc unit) & SC_B(6mv or 49 adc unit). |
||
| 624 | 1) HVs(L,R,T) = (900,1030,1030) |
||
| 625 | 2) HVs(L,R,T) = (880,1030,1000) |
||
| 626 | 3) HVs(L,R,T) = (860,1030,975) |
||
| 627 | 4) HVs(L,R,T) = (840,1030,950) |
||
| 628 | 5) HVs(L,R,T) = (820,1030,930) |
||
| 629 | |||
| 630 | |||
| 631 | 4172-4189 debug GEM and coda |
||
| 632 | |||
| 633 | ======================================================================== |
||
| 634 | 20230214 Pedestal runs |
||
| 635 | |||
| 636 | 4190-4191 pedestal runs, beam off, HVs on, hallc_fadc config |
||
| 637 | 4192 pedestal runs, beam off, HVs off, hallc_fadc config |
||
| 638 | 4193 trash, pedestal runs, beam off, HVs off, hallc_fadc_ssp config, ssp fail |
||
| 639 | 4194 pedestal runs, beam off, HVs off, hallc_fadc config |
||
| 640 | 4195 trash, debug ssp |
||
| 641 | 4196-4197 pedestal runs, beam off, HVs off, hallc_fadc_ssp config, With all 4 GEM detectors, daq rate =3.7kHz, saturated |
||
| 642 | 4198-4200 pedestal runs, beam off, HVs on, hallc_fadc_ssp config, With all 4 GEM detectors, daq rate =3.7kHz, saturated |
||
| 643 | |||
| 644 | ====Only shower and GEM HV on==== |
||
| 645 | 40uA CW on dummy |
||
| 646 | 4201 TS6, trash |
||
| 647 | 4202 TS4, PS4=0, threshold: 100mV(ShowerSum) Shower HV (L=700, R=730, T=680 V) |
||
| 648 | 4203 TS4, PS4=0, threshold: 150mV(ShowerSum) Shower HV (L=700, R=730, T=680 V) |
||
| 649 | 4204 TS4, PS4=0, threshold: 150mV(ShowerSum) Shower HV (L=900, R=1030, T=1030 V) change GEM latancy to 59, beam current to high, trash |
||
| 650 | 4205 TS4, PS4=0, threshold: 150mV(ShowerSum) Shower HV (L=900, R=1030, T=1030 V), taken on beam ramp up |
||
| 651 | |||
| 652 | ===All HV on=== |
||
| 653 | 2uA CW beam on dummy tartet |
||
| 654 | 4206 TS4, PS4=0, threshold: 200mv(ShowerSum), rate=2.0kHz Shower HV (L=900, R=1030, T=1030 V) |
||
| 655 | 4207 TS2, PS2=0, threshold: 5mv(ShowerSum), 5mv(SC_D), 6mv(SC_B), rate=3.3kHz Shower HV (L=900, R=1030, T=1030 V) |
||
| 656 | 4208 TS2, PS2=0, threshold: 5mv(ShowerSum), 5mv(SC_D), 6mv(SC_B), rate=2.7kHz Shower HV (L=880, R=1030, T=1010 V) |
||
| 657 | 4209 TS2, PS2=0, threshold: 5mv(ShowerSum), 5mv(SC_D), 6mv(SC_B), rate=2.3kHz Shower HV (L=860, R=1030, T=990 V) |
||
| 658 | 4210 TS2, PS2=0, threshold: 5mv(ShowerSum), 5mv(SC_D), 6mv(SC_B), rate=2.0kHz Shower HV (L=840, R=1030, T=970 V) |
||
| 659 | |||
| 660 | Recommented HVs: (L=850, R=1030, T=970 V) ---> MIP at 600 |
||
| 661 | Used in FermiLab beam test: (L=760, R=880, T=860 V) |
||
| 662 | |||
| 663 | ==20230217: test trigger latency== |
||
| 664 | 4211-4213 trash, no beam, |
||
| 665 | 4214 TS1, PS1=3, threshold: 50mV (CerSum) & 200mv(ShowerSum), Shower HV (L=760, R=880, T=860 V) |
||
| 666 | 4215 TS2, PS2=0, threshold: 5mv(ShowerSum), 5mv(SC_D), 6mv(SC_B), Shower HV (L=760, R=880, T=860 V) |
||
| 667 | 4216 TS5, PS5=5, threshold: 40mv(SC_B), Shower HV (L=760, R=880, T=860 V) |
||
| 668 | |||
| 669 | conclusion: |
||
| 670 | 1) TS5: SC_B signal is 200ns earlier than TS5 |
||
| 671 | 2) TS4: Shower_L,Shower_R,Shower_T are 200ns earlier than TS4, ShowerSum is 6ns later than Shower_L |
||
| 672 | 3) TS1: only one peak, but showers have a wide range of 12~14 windows |
||
| 673 | 4) TS2: only one peak, but most detectors have a wide range of 14-16 windows |
||
| 674 | 5) SC_D, SC_B, CerSum have 44ns,38ns,44ns cable delay. SC_B is 6ns later than SC_D before delay. |
||
| 675 | After these delay, SC_B is 16ns later than ShowerSum, CerSum is 4ns later than ShowerSum. |
||
| 676 | We need to reduce the delay cable length for SC_B, SC_D and CerSum. |
||
| 677 | 6) TS6 is 352ns (or 88 windows) behind its input signals |
||
| 678 | |||
| 679 | Trigger signal at Slot7_ch07 is 9 windows eariler than the trigger signal at slot8_ch15. Because Slot7_ch07 signal |
||
| 680 | is only 1 window later than that of Slot8_ch15, we should set FADC250_W_OFFSET 10 windows 40ns eariler in order to |
||
| 681 | match these 2 slots in timing. Therefore I changed slot7 from "FADC250_W_OFFSET 1060" to "FADC250_W_OFFSET 1100". |
||
| 682 | I also changed slot7 FADC250_ALLCH_DELAY from 160ns to 80ns. |
||
| 683 | FADC250_ALLCH_DELAY 80 80 80 80 80 80 80 0 80 80 80 80 80 80 80 80 |
||
| 684 | |||
| 685 | 4217 will be the first run after FADC slo7 config change in FADC250_ALLCH_DELAY and FADC250_W_OFFSET. |
||
| 686 | |||
| 687 | |||
| 688 | ======================================================================== |
||
| 689 | 4217 TS4 good data, need to verify if Shower HV(L,R,T) = (760,880,860)? |
||
| 690 | 4218 TS2 good data, need to verify if Shower HV(L,R,T) = (760,880,860)? |
||
| 691 | |||
| 692 | check TS6 latency, trash run are removed |
||
| 693 | 4219-4221 Trash |
||
| 694 | 4222-4225 TS6, only slot8 is useful, Shower HV(L,R,T) = (760,880,860), peak location is 5 windows earilier than TS4 |
||
| 695 | 4226-4238 Trash |
||
| 696 | 4239-4240 TS6, only slot8 is useful, Shower HV(L,R,T) = (850,1030,970), peak location is 5 windows earilier than TS4 |
||
| 697 | 4241-4242 Trash |
||
| 698 | 4243-4247 TS6, only slot8 is useful, Shower HV(L,R,T) = (850,1030,970), peak location is the same as TS4 |
||
| 699 | 4248-4250 TS4, Shower HV(L,R,T) = (850,1030,970), |
||
| 700 | 4251 TS2, Shower HV(L,R,T) = (850,1030,970), |
||
| 701 | 4252-4260 Trash, FADC need to reboot |
||
| 702 | 4261 TS4, only Shower HVs are on. Shower HV(L,R,T) = (850,1030,970), TS4 delay = 40 windows, first 100k are pulse triggers |
||
| 703 | 4262 TS1 and TS2, all HVs are on without GEM. Shower HV(L,R,T) = (850,1030,970), TS1 TS2 delay = 4,7 windows |
||
| 704 | 4263 TS1 and TS2, all HVs are on without GEM. Shower HV(L,R,T) = (850,1030,970), TS1 TS2 delay = 4,7 windows |
||
| 705 | ////////////////////////////////////////////////////////////////////////////////////// |
||
| 706 | no TS delay |
||
| 707 | 4264 TS4, PS4=3, thredhold=200mv(ShowerSum), rate=1.5kHz |
||
| 708 | 4265 TS4, PS4=3, thredhold=40mv(ShowerSum), rate=12.8kHz, daq Saturated |
||
| 709 | 4266 TS4, PS4=3, thredhold=40mv(ShowerSum), rate=12.8kHz, daq Saturated |
||
| 710 | 4267 TS4, PS4=5, thredhold=40mv(ShowerSum), rate=12.8kHz, daq Saturated |
||
| 711 | 4268 TS4, PS4=10, thredhold=40mv(ShowerSum), rate=7.8kHz, |
||
| 712 | 4269 TS4, PS4=10, thredhold=40mv(ShowerSum), rate=7.8kHz, |
||
| 713 | 4270 TS4, PS4=10, thredhold=40mv(ShowerSum), rate=7.8kHz, |
||
| 714 | 4271 TS4, PS4=10, thredhold=40mv(ShowerSum), rate=7.8kHz, |
||
| 715 | 4272 TS1, PS1=5, thredhold=50mv(CerSum),20mv(ShowerSum), rate=12.8kHz, daq Saturated |
||
| 716 | 4273 trash |
||
| 717 | 4274 TS1, PS1=10, thredhold=50mv(CerSum),20mv(ShowerSum), rate=7.8kHz |
||
| 718 | /////////////////////////////////////////////////////////////////////////////////////// |
||
| 719 | |||
| 720 | How to determine TS6 latency: |
||
| 721 | basic knowledge: |
||
| 722 | A) TS6 (FADC trigger) is ~88 windows behind FADC input signal (viewed in DiagGui). |
||
| 723 | B) TS4(NIM trigger) is about 49 windows behind the input signal of logic unit (viewed in data). |
||
| 724 | |||
| 725 | 1) Use TS4 (NIM trigger, trigger by slot8_ch14), plug the trigger signal(L1A) into FADC slot7 and slot8. |
||
| 726 | Modify FADC250_W_OFFSET and FADC250_ALLCH_DELAY of FADC config file such that the peaks of |
||
| 727 | these 2 signals stay at the same time in slot7 and slot8. The following is my current setting. |
||
| 728 | Trigger signals have ZERO delay. |
||
| 729 | |||
| 730 | slot7: FADC250_W_OFFSET 1100 |
||
| 731 | slot7: FADC250_ALLCH_DELAY 80 80 80 80 80 80 80 0 80 80 80 80 80 80 80 80 |
||
| 732 | slot8: FADC250_W_OFFSET 1060 |
||
| 733 | slot8: FADC250_ALLCH_DELAY 40 80 40 40 80 80 80 40 40 40 40 40 40 40 40 0 |
||
| 734 | Here is the peak location of each channel. |
||
| 735 | double kSlot7PeakPos_4[16] = { 44.5, 43.5, 44.5, 44.5, 43.5, 43.5, 43.5, 78.5, 43.5, 43.5, 43.5, 43.5, 43.5, 43.5, 43.5, 43.5 }; |
||
| 736 | double kSlot8PeakPos_4[16] = { 40.5, 35.5, 41.5, 39.5, 38.5, 37.5, 31.5, 35.5, 35.5, 36.5, 37.5, 37.5, 37.5, 37.5, 38.5, 77.5 }; |
||
| 737 | Note that the trigger signal of slot7_ch07 is 6ns late than that of slot8_ch14 because it gord thrught an extra FIFO. |
||
| 738 | |||
| 739 | 2) From the above peak location, we can see that TS6_peak = 43.5 + 94 = 137.5 (windows). To align TS4 to TS6, we have to |
||
| 740 | delay TS4 by 137.5 - 77.5 = 60 windows. In my case, I change the readout list, delay TS4 by 54 windows. |
||
| 741 | We fisrtly change FADC250_W_OFFSET to view the peak location of these 2 trigger signals. |
||
| 742 | To keep slot7_ch07 at 78.5, slot7_W_offset should be 1100 - 60x4 = 860. |
||
| 743 | To keep slot8_ch15 at 77.5, slot8_W_offset should be 1060 - 60x4 = 820. |
||
| 744 | Since FADC trigger is 88 windows later than its inputs, it is impossible to view inputs and trigger within a 400ns windows. |
||
| 745 | Therefore do not bother to change slot7 delay. But we can add 60 windows (240ns) delay to slot8 such that the peaks of all |
||
| 746 | channels stay the same location. |
||
| 747 | |||
| 748 | slot7: FADC250_W_OFFSET 860 |
||
| 749 | slot7: FADC250_ALLCH_DELAY 80 80 80 80 80 80 80 0 80 80 80 80 80 80 80 80 |
||
| 750 | slot8: FADC250_W_OFFSET 820 |
||
| 751 | slot8: FADC250_ALLCH_DELAY 256 296 256 256 296 296 296 256 256 256 256 256 256 256 256 0 |
||
| 752 | |||
| 753 | Take a run using TS6 trigger with the above changes to determine the peak location for 2 trigger signals. |
||
| 754 | |||
| 755 | ======================================================================== |
||
| 756 | 20230219 run list |
||
| 757 | All HVs are on without GEM. Shower HV(L,R,T) = (850,1030,970). |
||
| 758 | 40uA CW beam on Li-7 target. |
||
| 759 | |||
| 760 | --------------------------------------------------- |
||
| 761 | List of HVs: |
||
| 762 | board1, 6kV, 8-ch: |
||
| 763 | Name:_GEM00,__,__,_GEM01,_GEM10,_GEM11,__,_Cer_D |
||
| 764 | HV:_______0,_0,_0,_____0,_____0,_____0,_0,___950 |
||
| 765 | |||
| 766 | |||
| 767 | Name:_SC_D,_SC_A,_SC_B,_X,_LASPD_t,_LASPD_b,_SC_C,_PreSh_L(SDU#1),_PreSh_R(THU#1),_PreSh_T(SDU#2),_Shower_L(SDU#4),_Shower_R(THU#2),_Shower_T(SDU#5),__CerA,__CerB,__CerC |
||
| 768 | HV:___1150,_1550,_1650,_0,_____800,_____900,_1600,___________1470,___________1740,___________1680,_____________850,____________1030,_____________970,___950,___950,___950 |
||
| 769 | |||
| 770 | 4275 TS4, PS=10, Threshold: 40mV(ShowerSum), rate=8.2kHz, Shower HV(L,R,T) = (850,1030,970) |
||
| 771 | 4276 TS2, PS=0, Threshold: 5mV(SC_D) & 5mV(ShowerSum) & 6mV(SC_B), Shower HV(L,R,T) = (850,1030,970), |
||
| 772 | rate=12.5kHz then detectors got saturated. 170k triggers |
||
| 773 | 4277 TS2, PS=0, Threshold: 5mV(SC_D) & 5mV(ShowerSum) & 6mV(SC_B), Shower HV(L,R,T) = (850,1030,970), |
||
| 774 | rate=12.5kHz then detectors got saturated. 988k triggers |
||
| 775 | 4278 TS2, PS=0, Threshold: 5mV(SC_D) & 5mV(ShowerSum) & 6mV(SC_B), Shower HV(L,R,T) = (850,1030,970), |
||
| 776 | rate=12.5kHz then detectors got saturated. 508k trigger |
||
| 777 | 4279 TS2, PS=0, Threshold: 5mV(SC_D) & 5mV(ShowerSum) & 6mV(SC_B), Shower HV(L,R,T) = (840,1030,970), |
||
| 778 | rate=12.5kHz then detectors got saturated. 856k triggers |
||
| 779 | 4280 TS2, PS=0, Threshold: 5mV(SC_D) & 5mV(ShowerSum) & 6mV(SC_B), Shower HV(L,R,T) = (840,1030,970), |
||
| 780 | rate=12.5kHz then detectors got saturated. 526k triggers |
||
| 781 | |||
| 782 | 4281 trash |
||
| 783 | 4282 pedestal. Beam off, HV off. |
||
| 784 | 4283 pedestal. Beam off, HV off. |
||
| 785 | 4284 pedestal. Beam off, HV on. Shower HV(L,R,T) = (840,1030,970), |
||
| 786 | 4285 pedestal. Beam off, HV on. Shower HV(L,R,T) = (850,1030,970). |
||
| 787 | |||
| 788 | ==================== End of 7 deg ==================================== |
||
| 789 | 3 | Jixie Zhang | |
| 790 | |||
| 791 | For 18deg data set, use this link: https://redmine.jlab.org/projects/solid-ecal/wiki/Hallc_beamtest_runlist_18deg?parent=2022_JLab_Hall_C_Beam_test |