Highrate trigger design » History » Revision 2
Revision 1 (Jixie Zhang, 01/23/2023 10:48 AM) → Revision 2/4 (Jixie Zhang, 01/23/2023 10:49 AM)
h1. Highrate trigger design and initial threshold =20230123 threshold== Threshold is applied to the height of the waveform: TS1: CerSum(200mv or 410 adc unit) & ShowerSum(70mv or 143 adc unit); TS2: SC_D(20mv or 164 adc unit) & ShowerSum(70mv or 143 adc unit) & SC_B(15mv or 123 adc unit). TS3: 2 out of these 3 inputs: CerSum(200mv or 410 adc unit), ShowerSum(50mv or 103 adc unit), SC_D(20mv or 164 adc unit); TS4: ShowerSum(100mv or 205 adc unit) TS5: SC_B(20mv or 164 adc unit). TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual individule input Here is a link to the trigger design document: https://redmine.jlab.org/attachments/1733