h1. Highrate trigger design and initial threshold 

 =20230123 threshold== 
 Threshold is applied to the height of the waveform: 
 TS1: CerSum(200mv or 410 adc unit) & ShowerSum(70mv or 143 adc unit);  
 TS2: SC_D(20mv or 164 adc unit) & ShowerSum(70mv or 143 adc unit) & SC_B(15mv or 123 adc unit). 
 TS3: 2 out of these 3 inputs: CerSum(200mv or 410 adc unit), ShowerSum(50mv or 103 adc unit), SC_D(20mv or 164 adc unit); 
 TS4: ShowerSum(100mv or 205 adc unit) 
 TS5: SC_B(20mv or 164 adc unit). 
 TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual individule input 