Highrate trigger design and initial threshold¶
=20230123 threshold==
Threshold is applied to the height of the waveform:
TS1: CerSum(200mv or 410 adc unit) & ShowerSum(70mv or 143 adc unit);
TS2: SC_D(20mv or 164 adc unit) & ShowerSum(70mv or 143 adc unit) & SC_B(15mv or 123 adc unit).
TS3: 2 out of these 3 inputs: CerSum(200mv or 410 adc unit), ShowerSum(50mv or 103 adc unit), SC_D(20mv or 164 adc unit);
TS4: ShowerSum(100mv or 205 adc unit)
TS5: SC_B(20mv or 164 adc unit).
TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual input
Here is a link to the trigger design document: https://redmine.jlab.org/attachments/1733