Project

General

Profile

Highrate trigger design » History » Revision 3

Revision 2 (Jixie Zhang, 01/23/2023 10:49 AM) → Revision 3/4 (Jixie Zhang, 03/09/2023 01:31 PM)

h1. Highrate trigger design and initial threshold 

 ==20230123 =20230123 threshold== 
 Threshold is applied to the height of the waveform: 
 TS1: CerSum(200mv or 410 adc unit) & ShowerSum(70mv or 143 adc unit);  
 TS2: SC_D(20mv or 164 adc unit) & ShowerSum(70mv or 143 adc unit) & SC_B(15mv or 123 adc unit). 
 TS3: 2 out of these 3 inputs: CerSum(200mv or 410 adc unit), ShowerSum(50mv or 103 adc unit), SC_D(20mv or 164 adc unit); 
 TS4: ShowerSum(100mv or 205 adc unit) 
 TS5: SC_B(20mv or 164 adc unit). 
 TS6: CerA#,CerB#,CerC#,CerD#(15mv or 31 adc unit) for each Cherenkov individual input 

 Here is a link to the trigger design document: https://redmine.jlab.org/attachments/1733 


 ==20230220== 
 TS1: CerSum(35mV or 72adc, 2pe) & ShowerSum(70mV or 143adc, 500MeV electron);  
 TS2: SC_D(35mV or 287adc) &    SC_B(35mV or 287adc);  
 TS3: SC_D(35mV or 287adc) &    SC_A(31mV or 254adc); 
 TS4: ShowerSum(140mV or 287adc, 1GeV electron); 
      or (70mV or 143adc, 500MeV electron); 
      or (15mV or 31adc, half MIP); 
     (120mV will keep 95% of 1-GeV electrons) 
 TS5: N/A. 
 TS6: CerA#,CerB#,CerC#,CerD#(5mV or 20 adc unit) for each Cherenkov individual input.