Run list » History » Version 17
Jixie Zhang, 01/01/2021 06:05 PM
1 | 1 | Alexandre Camsonne | h1. Run list |
---|---|---|---|
2 | |||
3 | 500 |
||
4 | |||
5 | 501 DAQ crashed |
||
6 | |||
7 | 502 short run threshold check |
||
8 | 2 | Alexandre Camsonne | |
9 | 503 threshold check |
||
10 | 3 | Alexandre Camsonne | |
11 | 512 better threshold check 1500 V on scintillators |
||
12 | 4 | Alexandre Camsonne | |
13 | 513 long cosmics run |
||
14 | 5 | Alexandre Camsonne | |
15 | 15 | Jixie Zhang | 514 new run but bad thresholds no event, trigger was added into fadc channel 9 |
16 | 14 | Jixie Zhang | HV from channel 0-7 are: 1300, 1250,1000, 1000, 1050, 2050, 1850, 2000 |
17 | 5 | Alexandre Camsonne | |
18 | 515 run with new HV and thresholds |
||
19 | 14 | Jixie Zhang | HV from channel 0-7 are: 1300, 1250,1000, 1000, 1050, 2050, 1850, 2000 |
20 | 6 | David Flay | |
21 | 516 |
||
22 | 1 | Alexandre Camsonne | |
23 | 14 | Jixie Zhang | 517 increase HV for channel 1 and 7: |
24 | HV from channel 0-7 are: 1300, 1300,1000, 1000, 1050, 2050, 1850, 2050 |
||
25 | 6 | David Flay | |
26 | 518 Changed latency from 100 to 60. Ensuing decoded run showed an error: |
||
27 | 9 | David Flay | @ |
28 | Couldn't find block level ! |
||
29 | 1 | Alexandre Camsonne | ERROR getting FADC slot 7 block header |
30 | 9 | David Flay | ERROR fadc slot 7 event data length -1 <= 0 |
31 | @ |
||
32 | 6 | David Flay | |
33 | 519 Aborted. Reset latency to 100. |
||
34 | |||
35 | 10 | David Flay | 520 New run with latency set to 100. Stopped to check quality on decoding; looks good. |
36 | 1 | Alexandre Camsonne | |
37 | 14 | Jixie Zhang | |
38 | 1 | Alexandre Camsonne | 521 12-29-20 15:22 Tue New run started |
39 | 14 | Jixie Zhang | |
40 | 522 12-31-20 17:40, Jixie increased preshower HVs |
||
41 | HV from channel 0-7 are: 1300, 1300,1000, 1000, 1050, 2150, 1950, 2150 |
||
42 | 16 | Jixie Zhang | |
43 | 523 12-31-20 18:36, Jixie increased preshower3 HV to 2250 |
||
44 | HV from channel 0-7 are: 1300, 1300,1000, 1000, 1050, 2150, 1950, 2250 |
||
45 | 17 | Jixie Zhang | |
46 | 524 |
||
47 | |||
48 | 525 01-01-21 :connected preshowers to pre-amplifier, set HV as the following: |
||
49 | HV from channel 0-7 are: 1400, 1300,1000, 1000, 1050, 2050, 1850, 2050 |
||
50 | |||
51 | |||
52 | 526 01-01-21: lower HV of SC1 by 50V: |
||
53 | HV from channel 0-7 are: 1350, 1300,1000, 1000, 1050, 2050, 1850, 2050 |