Runlist » History » Revision 75
Revision 74 (Jixie Zhang, 02/22/2021 04:42 PM) → Revision 75/80 (Jixie Zhang, 02/23/2021 02:41 PM)
1. Runlist for fermilab beam test beam hit the right edge of top Ecal New HV is: 1260, 1300, 920, 960, 940, 1940, 1780, 2100 777 First run - MWPC trigger - 783 Preshower channels set to 2V range in FADC, new HV is: 1260, 1300, 920, 960, 940, 1840, 1680, 2000. TS1 and TS2 784 TS1 and TS2 - move detector position so beam is hitting the center of three ECals, junk ECals 785 New HV is: 1160, 1200, 820, 860, 840, 1840, 1680, 2000 786 TS1 only - beam centered on calorimeter 787 lower HV on preshower, New HV is: 1260, 1300, 820, 860, 840, 1740, 1580, 1900 788 790 junk 792 793 reduce 100 V more on preshower, New HV is: 1260, 1300, 820, 860, 840, 1640, 1480, 1800 short run PEB1 crashed 795 switch to FADC only config TiIntelvmeha8 and use Changing down stream Cerenkov N2 pressure from 4.0 to 0.8 psia ===========good data start from here=================== 01/14 22:55 796 move to Top block, use this New HV: 1260, 1300, 880, 920, 940, 1640, 1440, 1800, FADC ch11 and ch12 swapped. These two channels are down stream Cherenkov. After swapped, Down cherenkov inner PMT is in ch12. 1800 797 798 move to left block 799 800 beam on the center of the left block, point B 801 802 beam on the center of the right block, point C 803 beam on the center of the top block, point A 804 beam on the center of 3 modules, 6.5k 805 2GeV, beam on the center of 3 modules, 31.7k 806 4GeV, beam on the center of 3 modules, -------------adjusting HV for 12GeV start------------ Request 16 GeV but MCR can not deliver it, switch to 12 GeV. We then determine the HV 807 12GeV HV: 1260, 1300, 880, 920, 940, 1640, 1440, 1800 ---38409 events. Ecal is saturated 808 12GeV HV: New HV is: 1260, 1300, 920, 960, 980, 1640, 1440, 1800 -->try to decrease HV by 40V but increased it by mistake 809, 810 coda crashed, junk 811 812 12GeV, New HV: 1260, 1300, 820, 860, 880, 1640, 1440, 1800, 17271 events. Still saturated 813 814 12GeV, New HV: 1260, 1300, 780, 820, 840, 1640, 1440, 1800 815 816 12GeV, New HV: 1260, 1300, 740, 820, 840, 1640, 1440, 1800 817 12GeV, New HV: 1280, 1280, 700, 820, 840, 1640, 1440, 1800, 8711 events -------------adjusting HV for 12GeV end-------------- 818 12 GeV e-, 34841 events 819 12 GeV e-, missed the start of the spill. Total event count is off by about 194 events. Event count = 20779 820 10 GeV e-, 80515 events. 821 8 GeV e-, 62788 events. 822 6 GeV e- 61530 events. ALl the above run MWPC chamber1 is not working. ===========1GeV=================== HV is: 1260, 1280, 760, 860, 880, 1640, 1480, 1800 823 824 825 5808 events 826, Switch to TS2 trigger, which is our own trigger. testing daq, short run 827, daq crashed, bad runs 828 use TS2 trigger, which is our own "SC1&SC2", 4190 events. 829, something wrong, bad run 830, CODA went wrong, no output file Switch back to TS1 831 Switch back to TS1, crashed junk 832 with 8303 events. 833 7396 events. lost MWPC data at the last few spills 834 835 836 with 8853 events 837 838 test daq, junk 839 daq crashed, junk 840 with 4856 events in coda. (MWPC shows 4859 events) 841 with 2102 events,(MWPC shows 2101 events in run) <<== this is normal, the last event from coda will not write into data file 842 with 2486 events 843 with 3803 events. 844 beam went down (bad run) 845 without MWPC daq running 846 only 1 spill since it is not synchronized with MWPC daq 847 1 GeV ===========6GeV=================== 848 6 GeV 849 6 GeV 850 6 GeV 851 6 GeV, 119066 events 852 with 49377 events calibration start------------ 853 center on the top block(1440, 252), with 68483 events. 854 center on the left block (1498, 347), with 69508 events. 855 center on the right block (1382, 347), with 68357 events. calibration end-------------- 856 with 185847 events 857 with events 193672 858 without MWPC daq, coda crashed, junk 859 without MWPC 860 with events 209800 861 with events 198022 ===========16GeV=================== 862, ecal HV is using 8GeV setting: 760, 860, 880 bad run, all saturated 863, change ecal HV: 720, 820. 840, bad run, all saturated 864 bad run, all saturated 865, change ecal HV: 700 780,800 bad run, sdu#4 saturated 866, bad run, sdu#4 saturated ===========12GeV=================== 867 868 869 -------------addjust table position start-------------- 870 motion table moved to (1429,315) 871 872 motion table moved to (1452,315) 873 874 875 motion table moved to (1461,315) 876 877 motion table moved to (1451,315) -------------addjust table position end---------------- 878 coda has 2 events less than MWPC daq 879 coda has 3 events less than MWPC daq 880 coda crashed, no output file, junk 881 882 bufferlevel=2, coda crashed, junk 883 -------------addjust table position start-------------- 884 Moved motion table from (1451, 315) vertical down by 2mm to (1451,313) 885 886 Moved motion table vertical down by 5mm to (1451,308) 887 888 Moved motion table vertical down by 3mm to (1451,305) 889 890 Moved motion table vertical down by 2mm to (1451,303) -------------addjust table position end---------------- 891 with 200407 events, 892 with 192133 events, 893 with 203303 events, 894 895 with 110758 events 896 coda crashed. 17661 events, data is still good 897 coda crashed, no output file, junk 898 with 98980 events, 899 with 85054 events. 900 with 164765 events. 901 168579 events. MWPC daq not start 902 calibration start---------------- 903 Moved table to (1451, 239), center on the top block 904 Moved table to (1510, 334), center on the left block 905 Moved table to (1393, 334), center on the right block calibration end----------------- ===================16GeV==================== beam still hitting the right block---------------------------- 906|907 Ecal HV: 660 760 780, 908|909 Ecal HV: 700 780 800, 910|911 Ecal HV: 760 860 880, MCR start to shrink beam spot size 912|913 Ecal HV: 660 760 780, 914|915 Adjust Ecal HV, also Lower Preshower3 HV by 40V, new HV: 1260 1280 640 760 760 1640 1480 1760, 916 Move table back to center---------------------------- 917 918|919 920|921 Ecal HV: 620 700 720, beam hit center O 922|923 Move table, beam hit the Top block MCR finished changing beam spot size calibration start========= 924 Ecal HV: 620 680 720, Top block 925 Move table, beam hit the Left block 926 MWPC daq not synchronize 927 928 Move table, beam hit the Right block 929 calibration end ========= 930 Move table, beam hit the center of 3 blocks 931 932 933 934 935 936 937 938 coda has 3 events less than MWPC daq 939 MWPC not run 940 941 942 943 944 ===================2GeV==================== HVis set to : SC1 SC2 Ecal1 Ecal2 Ecal3 PrSh1 PrSh2 PrSh3 -1260 -1280 -760 -860 -880 -1640 -1480 -1800 945 946 947 948 daq crashed, no data 949 only 863 events 950 - 969 production ===================4GeV==================== 970 971 972 973 974 coda crashed, no output file 975 detector are below beam line, good for checking pedestal, in run 975, Cherenkov raw signal are connected to FADC, previously we connected another copy signal with diff. cable length 976 detector are below beam line, good for checking pedestal 977 978 Upstream cherenkov HV changed from 1700 to 1640 984 coda crashed, no output file 985 987 change coda latency from 100 to 150 to test daq. 988 989 change coda latency back to 100 991 trash 995 Changed Cherenkov HVs from (1640,1700,1700) to (1600,1740,1720) . 996 stopped with only one spill. Did not synchronize to MWPC daq 997 ///////////////////// PMT: Up, Outer, Inner <=977: 1700,1700,1700 978-994: 1640,1700,1700 995-997: 1600, 1720, 1740 998|999: 1640, 1780, 1740 1000|1001: 1700, 1840, 1740 >=1002: 1740, 1880, 1740 ///////////////////////// 998 HV: 1640, 1780, 1740. Only one spill. Stop to view event 999 1000 HV: 1700, 1840, 1740. Only one spill. Stop to view event 1001 1002 HV: 1740, 1880, 1740. Only two spill. Stop to view event 1003 MWPC has one event less than CODA, this run might be good 1004 1005 MWPC has one event more than CODA 1006 1007 1008 calibration start 1009 Moved table to (1505, 337), center on the left block 52034 events 1010 Moved table to (1389, 337), center on the right block 77621 events 1011 Moved table to (1447, 243), center on the top block calibration end ===================8GeV==================== HV setting is SC1 SC2 Ecal1 Ecal2 Ecal3 PrSh1 PrSh2 PrSh3 -1260 -1280 -760 -860 -880 -1640 -1480 -1800 ----------------------------------- these 3 runs can be used to calibrate HV setting of the above, which is also used in 1,2,4,6 GeV data calibration start-------- 1012 top block, saturated due to pile up 1013 left block, saturated due to pile up 1014 right block, saturated due to pile up calibration end---------- ----------------------------- Change to the following from run 1015 -1260 -1280 -720 -820 -840 -1640 -1480 -1800 calibration start-------- 1015,1016 right block, 1017 left block 1018 top block calibration end---------- 1019 Move motion table to the center of 3 blocks, point O 1020 coda crashed, part of the data is good 1021 coda crashed, part of the data is good 1022 coda crashed, no output ... 1028 MWPC has 2 more events than CODA ... 1031 MWPC has 3 more events than CODA 1032 1033 713306 events at coda. Coda has 1 event more than MWPC <<=== this is a good run ==================10GeV==================== 1034 ==================1 GeV==================== 1035 1036 events# 10027 1037 events# 10940 1038 with events 10794 1039 with events 12529 1040 with events 10982 1041 with events 12035 1042 1 GeV 1043 1 GeV 1044 junk run (missed first spill) 1045 1 GeV 1046 1 GeV 1047 1 GeV, out of sync at 23:04:11 CST (end of run) 1048 1 GeV 1049 1 GeV, off by 2 events at 23:46:50 CST 1050 1 GeV 1051 1 GeV 1052 1 GeV 1053 1 GeV 1054 1 GeV 1054 289234 events 1055 308115 events 1056 28310 events ==================2 GeV==================== 1057 MWPC has 321476 events, but CODA ended with 321477 events, CODA has one more event. This one extra event was added when I clicked "End" on CODA. Might not be a problem, need to check. <<----confirmed by Alex that the last extra event of coda will not be written into the output file. 1058 MWPC has 367897 events, CODA ended with 367898 events. The same reason as 1057. 1059 MWPC 356721 events, CODA ended with one more event (356722). . The same reason as 1057. 1060 MWPC 316666 events, CODA ended with 316667 event. The same reason as 1057. 1061 MWPC 233967 events, CODA ended with 233967 events. ==================6 GeV==================== 1062 1063 requested lower rate after 5 spills 1064 1065 ==================10 GeV==================== HV setting is: HV for FADC channel 0 to 7: SC1 SC2 Ecal1 Ecal2 Ecal3 PrSh1 PrSh2 PrSh3 -1260 -1280 -720 -820 -840 -1640 -1480 -1800 1066 1067 ... 1072 coda has 3 events less than MWPC ... 1074 Moved table from (1447, 306) to (1442,306), one spill only 1075 120291 events. 1076 10820 events. MWPC daq did not run 1077 54030 events. MWPC daq did not run 1078 with events 566363 1079 with events 260990 1080 with events 237995 1081 with events 247434 1082 with events 278606 1083 with events 258176 1084 with events 367690 1085 with events 252462 1086 with events 217253; Run stopped early due to inconsistency with MWPC DAQ count 217256 1087 with events 309246 1088 with events 20566. calibration done by Jixie: calibration start-------- 1089 point A, top block, (1442, 243) , MTSCL5~=80k, rate is too high 1090 point A, top block, (1442, 243) , requested MTSCL5~=60k, rate is still high 1091 point B, top block, (1500, 337) 1092 point C, top block, (1384, 337) 1093 point C, top block, (1384, 337) , requested MTSCL5~=30k, rate is still high 1094 point B, top block, (1500, 337) 1095 point A, top block, (1442, 243) calibration end---------- ===============120 GeV Proton=============== beam size is ~3.5 mm (x) x ~2.8 mm (y). calibration start-------- 1096 top block, point A (1442, 243). NO MWPC, 7 spills, HVs=-1260 -1280 -600 -680 -720 -1640 -1480 -1760 1097 top block, point A (1442, 243). NO MWPC, 3 spills, HVs=-1260 -1280 -560 -620 -640 -1600 -1440 -1720 1098 NO MWPC, 7 spill 1099 NO MWPC, 1 spill 1100 NO MWPC, 6 spill run 1101. center of 3 blocks, point O (1442, 306). NO MWPC, 1 spills, HVs= -1260 -1280 -560 -600 -620 -1600 -1440 -1720 1102 NO MWPC, 6 spill 1103 center of 3 blocks, point O (1442, 307). NO MWPC, 2 spills, HVs= -1260 -1280 -540 -600 -620 -1600 -1440 -1720 calibration end---------- 1104 NO MWPC, 59 spills 685357 events 1105 (1500, 338) point B, 2 spill 1106 (1500, 338) point B, 450480 events 1107 (1500, 338) point B, 459505 events 1108 (1384, 338) point C, 26425 events, 2 spills 1109 (1384, 338) point C, 470569 events 1110 (1384, 338) point C, 495870 events 1111 (1442, 244) point A, 26323 events, 2 spills 1112. ... 495424 events 1113. ... coda lost roc2 from 703k events, MWPC still runs, part of the data saved 1114....378889 events 02:05 Moved table to (1442, 307) point O 1115. ... 1 spill 1116. ... 156652 events, 12 spill 1117. ... 389498 events, 30 spill 1118. ... 837943 events, 64 spill.