Project

General

Profile

Run List » History » Revision 144

Revision 143 (Simona Malace, 09/05/2020 11:28 AM) → Revision 144/176 (Simona Malace, 09/05/2020 11:29 AM)

h1. Run List2 - after the Covid shutdown  

 _*Calibration runs in prep for taking data at high rate*_ 

 _*Run 185*_: Pulser run to look at MaPMT vtpPulser 

 _*Run 188*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers. 

 _*Run 189*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers. 

 _*Run 190*_: Cosmic run to look at Calo vtpScaler. Trigger in VTP is Calo only. Bad calo 6-3 is all triggers. 

 _*Run 202*_: cosmic run. Calo preamp. All Hv 1200 

 _*Run 205*_: cosmic run. Calo preamp. All Hv 1200, except 9-1,9-2 HV1100 

 _*Run 206*_: maPMT checks -pulser trigger 

 _*Run 207*_: maPMT checks -pulser trigger 

 _*Run 208*_: maPMT checks -pulser trigger - after taking new PEDs 

 _*Run 209*_: maPMT checks -pulser trigger - after taking new PEDs 

 _*Run 210*_: comsics; triggering on calo only 

 _*Run 211*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20 

 _*Run 212*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 instead of 20 

 _*Run 213*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 18) instead of 20; increased HV for 44 from 1085 to 1095 V 

 _*Run 213*_: maPMT checks -pulser trigger - after taking new PEDs; Cher th at 17 (except for 32 which is at 19) instead of 20;  

 _*Run 215*_: Calo gain matching (vtpScalers) 
 everything at 1200 V except for: cal-92 at 1000 V; cal-64 at 1150 V; cal-91 at 1100 V 

 _*Run 216*_: Calo gain matching (vtpScalers) 
 everything the same as for run 215 except for cal-2 at 1170 V; cal-3 at 1230 V; cal-4 at 1265 V 

 _*Run 218*_: Calo gain matching (vtpScalers) 
 everything the same as for run 216 except for cal-3 at 1210 V; cal-4 at 1240 V; cal-51 at 1300 V 

 _*Run 219*_: Calo gain matching (vtpScalers) 
 only cal-4, cal-51 and cal-64 stayed the same as for run 218 everything else changed as follows: cal-52 at +60 V; cal-53 at +60 V; cal-54 at +15 V; cal-61 at +10 V; cal-62 at +110 V; cal-63 at +50 V; cal-71 at +110 V; cal-72 at +70 V; cal-73 at +55V; cal-74 at +80 V; cal81 at +110 V; cal-82 at +65 V; cal-83 at +35 V; cal-84 at +35 V; cal-91 at +90 V; cal-92 at+10 V; cal-93 at +40 V; cal-94 at +80 V 

 _*Run 220*_: Calo gain matching (vtpScalers) 
 everything stayed the same as for run 219 except for: cal-2 at 1180 V; cal-4 at 1247 V; cal-51 at 1350 V; cal-52 at 1265 V; cal-53 at 1285 V; cal-62 at 1342 V; cal-71 at 1345 V; cal-72 at 1310 V; cal-73 at 1262 V; cal-74 at 1320 V; cal-81 at 1380 V; cal-84 at 1255 V; cal-91 at 1280 V; cal-92 at 1045 V; cal-94 at 1320 V 

 _*Run 222*_: Calo gain matching (vtpScalers) 
 everything stayed the same as for run 220 except for: cal-1 at 1190 V; cal-3 at 1220 V; cal-51 at 1440 V; cal-52 at 1310 V; cal-53 at 1295 V; cal-61 at 1220 V; cal-62 at 1350 V; cal-63 at 1260 V; cal-64 at 1130 V; cal-71 at 1315 V; cal-72 at 1345 V; cal-73 at 1250 V; cal-74 at 1355 V; cal-81 at 1480 V; cal-82 at 1245 V; cal-83 at 1240 V; cal-84 at 1240 V; cal-91 at 1265 V; cal-93 at 1250 V; cal-94 at 1240 V  

 _*Run 223*_: Calo gain matching (vtpScalers) 
 everything stayed the same as for run 222 except for: cal-51 at 1400 V; cal-52 at 1285 V; cal-64 at 1140 V; cal-71 at 1330 V; cal-72 at 1335 V; cal-74 1335 V; cal-81 at 1430 V; cal-82 at 1255 V; cal-91 at 1275 V; cal-93 at 1245 V; cal-94 at 1285 V; cal-1 at 1195 V; cal-3 at 1212 V; cal-4 at 1242 V 

 _*Run 224*_: Calo gain matching (vtpScalers) 
 everything stayed the same as for run 223 except for: cal-91 at 1280 V 

 _*Run 225*_: Calo gain matching (vtpScalers) 
 everything stayed the same as for run 224 except for: cal-91 at 1300 V 

 _*Run 226*_: Calo gain matching (vtpScalers); changed cal-91 from 1300 V to 1260 V 

 _*Run 227*_: Calo gain matching (vtpScalers); changed cal-91 from 1260 V to 1200 V 

 _*Run 229*_: Calo gain matching (vtpScalers); changed cal-91 from 1200 V to 1150 V 

 _*Run 230*_: Calo gain matching (vtpScalers); changed cal-91 from 1150 V to 1170 V 

 _*Run 231*_: Calo gain matching (vtpScalers); changed cal-91 PMT and base; HV for cal-91 at 1250 V 

 _*Run 232*_: Calo gain matching (vtpScalers); nothing changed compared to run 231 just taking more data 

 _*Run 233*_: Calo gain matching (vtpScalers); changed cal-91 from 1250 to 1235 V 

 _*Run 239*_: Calo gain matching overnight run (vtpScalers); coda lost connection with EB when stopped and had to kcoda 

 _*vtp Pulser runs for maPMTs checks*_ 

 _*Beam data - tune beam*_ 

 _*Run 262*_: beam 

 _*Run 263*_: beam 

 _*Run 264*_: beam; calo TH from 100 to 150 channels - good beam 

 _*Run 265*_: beam;  

 _*Run 266*_: beam;  

 _*Run 267*_: beam;  

 _*Run 268*_: beam;  

 _*Run 269*_: beam;  

 _*Run 269*_: beam; changed cal-94 from 1291 to 1296 V; cal-51 from 1400 to 1404 V; cal-52 from 1285 to 1289 V; cal-53 from 1295 to 1301 V; cal-54 1210 to 1214 V 

 _*Run 270*_: beam; 

 _*Run 271*_: beam; changed cal-51,62,53,64 TH from 150 to 120 

 _*Run 271*_: beam;  

 _*Run 272*_: beam;  

 _*Run 273*_: beam; changed cal-94 HV from 1296 to 1306 V 

 _*Run 275*_: beam; changed maPMT TH from 20 to 200 

 _*Run 276*_: beam; changed maPMT TH back 20 

 _*Run 277*_: beam; vtpPulser with beam 

 _*Run 278*_: beam; vtpScaler - junk, almost no beam 

 _*Run 279*_: evening beam; vtp scalers 

 _*Run 280*_: evening beam; vtp scalers 

 _*Run 281*_: evening beam; vtp scalers; changed the CHER TH from 20 to 10 

 _*Run 282*_: evening beam; vtp scalers; CHER TH back to 20  

 _*Run 284*_: evening beam; vtp scalers;  


 _*CW beam*_ 

 _*Run 285*_: CW beam; crappy beam 

 _*Run 287*_: CW beam; a bit better beam 

 _*Run 289*_: CW beam; a bit better beam 

 _*Run 290*_: CW beam; a bit better beam; vtpPulser 

 _*Run 291*_: CW beam; a bit better beam; vtpScaler 

 _*Run 292*_: tune beam; Moller run; all CAL TH at 120 now; crappy beam 

 _*Run 293*_: tune beam 

 _*Run 294*_: CW beam 

 _*Run 295*_: CW beam 

 _*Run 296*_: CW beam 

 _*Run 297*_: mostly tune beam 

 _*Run 298*_: tune + CW beam - vtpPulser; crappy beam; Moller still on 

 _*Run 299*_: tune + CW beam - vtpPulser; crappy beam; Moller still on 

 _*Run 300*_: tune + CW beam - vtpPulser; Moller still on 

 _*Run 301*_: tune + CW beam - vtpPulser; Moller still on 

 _*Run 302*_: CW beam, good beam, vtpScalers, 1 muA on no target 

 _*Run 304*_: junk 

 _*Run 305*_: cosmics 

 _*Run 306*_: junk 


 _*Run 307*_: CW 1 muA "no target"; vtpScalers 

 _*Run 308*_: CW 1 muA "no target"; vtpPulser 

 _*Run 309*_: CW 1.4 muA "no target"; vtpPulser - trippy beam 

 _*Run 310*_: CW 1.4 muA "no target"; vtpPulser - kind of trippy beam 

 _*Run 311*_: CW 1.4 muA "no target"; vtpScaler - trippy beam 

 _*Run 312*_: CW 1.95 muA "no target"; vtpScaler  

 _*Run 313*_: CW 1.95 muA "no target"; vtpPulser 

 _*Run 314*_: CW 0.5 muA "no target"; vtpScalers 


 _*LAPPD installation*_ 


 _*Run 315*_: cosmics, calo on; vtpScalers; CALO TH as for beam production 

 _*Run 316*_: cosmics, calo on; vtpScalers; all CALO TH at 100 - junk 

 _*Run 317*_: cosmics, calo on; vtpScalers; all CALO TH at 100 -    a bit of beam too :) 

 _*Run 318*_: beam, calo on; vtpScalers; all CALO TH at 120  

 _*Run 319*_: beam, calo on; vtpScalers; all CALO TH at 120  

 _*Run 320*_: beam, calo on; vtpScalers; all CALO TH at 120  

 _*Run 321*_: beam, calo on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo only 

 _*Run 322*_: beam, calo on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo+S2  

 _*Run 323*_: beam, calo on, S2 on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo+S2 - 3He run 

 _*Run 324*_: beam, calo on, S2 on; vtpScalers; all CALO TH at 120; S2 HV ON; trigger calo+S2 - Ref cell run 

 _*Run 325*_: cosmics; CALO TH at 100; triggering on CALO only 

 _*Run 326*_: troubleshooting S2-5 

 _*Run 327*_: troubleshooting S2-5 

 _*Run 328*_: troubleshooting S2-5 

 _*Run 329*_: troubleshooting S2-5 

 _*Run 330*_: cosmics; calo trigger only; changed CAL-94 from 1306 V to 1320 V 

 _*Run 331*_: beam; calo trigger only;  

 _*Run 332*_: beam; calo trigger only; took fresh PEDs after changing slots 3,4,5,6 in config file - junk, forgot to turn ON the HV after taking PEDs 

 _*Run 333*_: beam; calo trigger only; took fresh PEDs after changing slots 3,4,5,6 in config file - 

 _*Run 334*_: beam; calo trigger only; changed S2-5 from 1380 to 1360 V; S2-2 from 1350 to 1360 V; S2-10 from 1345 to 1360 V; S2-11 from 1380 to 1395 V 

 _*Run 335*_: beam; calo trigger only; changed S2-5 from 1360 to 1375 V;  

 _*Run 336*_: beam; calo trigger only; changed S2-5 from 1375 to 1380 V;  

 _*Run 337*_: cosmics; calo trigger only; 

 _*Runs 338-343*_: junk 

 _*Run 344*_: vtPulser (no beam); LAPPD HV on; TH =10 channels 

 _*Run 345*_: vtPulser (no beam); LAPPD HV on; TH =20 channels 

 _*Run 346*_: vtPulser (no beam); LAPPD HV on; TH =20 channels 

 _*Run 347*_: vtPulser (no beam); LAPPD HV on; TH =20 channels 


 _*LAPPD beam*_ 

 _*Run 347*_: vtScalers (ref cell); LAPPD HV on; TH =20 channels 

 _*Run 348*_: vtScalers (ref cell); LAPPD HV on; TH =20 channels 

 _*Run 349*_: vtScalers (ref cell); LAPPD HV on; TH =20 channels 

 _*Run 350*_: vtScalers (ref cell); LAPPD HV on; TH =70 channels 

 _*Run 351*_: junk 

 _*Run 352*_: vtScalers (ref cell);; LAPPD HV on; TH =70 channels; CAL TH 200 

 _*Run 354*_: vtPulser (ref cell);; LAPPD HV on; TH =20 channels; CAL TH 200 

 _*Run 355*_: vtPulser (no beam);; LAPPD HV on; TH =20 channels; CAL TH 200 



 _*LAPPD beam - Sep 05*_ 


 _*Run 356*_: vtScaler (30 muA beam);; LAPPD HV on; TH =20 channels; CAL TH 120 --> may be junk; CODA was not behaving 

 _*Run 357*_: vtScaler (30 muA beam);; LAPPD HV on; TH =20 channels; CAL TH 120 


 h2. Run List PreCovid 

 *MODE 3 Runs - Nitrogen; all detector channels ON*; Cher channels with zero FADC threshold; 3-fold coin 

 _*Run 54*_: short run to test the analyzer 

 _*Run 55*_: done 

 _*Run 59*_: done 

 *MODE 3 Runs - CO2; all detector channels ON* - 3-fold coin 

 _*Run 63*_: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero  

 _*Run 64*_: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero 

 _*Run 65*_: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels  

 _*Run 66*_: Same as run 65.  

 _*Run 67*_: adjusted Calorimeter HVs  

 _*Run 68*_: adjusted Calorimeter HVs  



 *MODE 1 Runs - CO2; all detector channels ON* - 3-fold coin 

 _*Run 69*_: to test Chao's code 


 *MODE 3 Beam Scintillator Gain matching* 

 _*Run 113, 114*_: changed the scin TH from 120 to 160  

 _*Run 115, 116*_: changed the scin TH from 160 to 210  

 _*Run 117*_: changed the scin TH from 210 to 250 

 _*Run 132*_: S2 and Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40 

 _*Run 134*_: Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40 

 *MODE 3 Beam Calorimeter Gain matching* 

 _*Run 135*_: Calo HV 4: 1775V, 5-1: 1800, 5-2: 1800, 5-3: 1900, 5-4:1800, 6-2:1800, 7-2:1775, 8-3: 1800, 8-4:1875, 9-1: 1800, 9-4:1850 

 _*Run 136*_: Calo HV 4: 1825V, 5-1: 1850, 5-2: 1850, 5-3: 1950, 5-4:1850, 7-2:18255, 9-2: 1600, 9-4:1900 

 _*Run 137*_: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950 

 _*Run 138*_: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950 

 _*Run 139*_: changed SUM_THR =3 ( SUM_THR is threshold on the CALO trigger) 

 _*Run 140*_:    changed SUM_THR =10 

 _*Run 141*_: changed individual calo thresholds from 40 to 80 

 _*Run 142*_: Calo HV 1:1750, 2:1825, 3:1800, 4:1875 

 _*Run 143*_: Add S2 plane to the VTP trigger ( before just calo), changed individual calo thresholds from 80 to 120 

 _*Run 144*_: same as 143 

 _*Run 145*_: same as 143 

 _*Run 146*_: same as 143 

 _*Run 147*_: same as 143 

 _*Run 148*_: changed individual calo thresholds from 120 to 150 

 _*Run 149*_: mistakenly changed calo thresholds 8-1,2,3,4 and 9-1,2,3,4 from 150 to 100 

 _*Run 150*_: changed time window from 768 to 200ns 

 _*Run 151*_: same as 150 


 _*Run 152*_: put calo thresholds 8-1,2,3,4 and 9-1,2,3,4 back to 150, set threshold for 1,2,3,4,5-1,-2,-3,-4 from    150 to 100 

 *MODE 3 Beam golden Runs - CO2; all detector channels ON* - S2 + calo (after calorimeter gain matching) 
 _*Run 153*_: same as 152 

 _*Run 154*_: same as 152 

 _*Run 155*_: Calo HV 6-1: 1725V, 6-3: 1650V, 7-3: 1800V, 9-2: 1500V 

 _*Run 156*_: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V 

 _*Run 157*_: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V 

 _*Run 159*_: same as 157, steady 30uA on C-OPTICS 

 _*Run 161*_: 30uA on Pol-He3 cell. Use same scaler data as run 160. 

 *MODE 1 Beam golden Runs - CO2; all detector channels ON* - S2 + calo (after calorimeter gain matching) 

 _*Run 158*_: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run 

 _*Run 160*_: 30uA on PolHe3 target, took scaler rates before this run