Project

General

Profile

Actions

Run List » History » Revision 29

« Previous | Revision 29/176 (diff) | Next »
Alexandre Camsonne, 07/18/2020 10:07 AM


Run List2

Run 185: Pulser run to look at MaPMT

Run List PreCovid

MODE 3 Runs - Nitrogen; all detector channels ON; Cher channels with zero FADC threshold; 3-fold coin

Run 54: short run to test the analyzer

Run 55: done

Run 59: done

MODE 3 Runs - CO2; all detector channels ON - 3-fold coin

Run 63: short to test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero

Run 64: test DAQ/Trigger - calo threshold at 10 channels; scin threshold at 120 channels; Cher threshold at zero

Run 65: test DAQ/Trigger - calo threshold at 40 channels; scin threshold at 120 channels; Cher threshold at 20 channels

Run 66: Same as run 65.

Run 67: adjusted Calorimeter HVs

Run 68: adjusted Calorimeter HVs

MODE 1 Runs - CO2; all detector channels ON - 3-fold coin

Run 69: to test Chao's code

MODE 3 Beam Scintillator Gain matching

Run 113, 114: changed the scin TH from 120 to 160

Run 115, 116: changed the scin TH from 160 to 210

Run 117: changed the scin TH from 210 to 250

Run 132: S2 and Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40

Run 134: Calo trigger, scin TH = 200, Cher TH = 20, Calo TH = 40

MODE 3 Beam Calorimeter Gain matching

Run 135: Calo HV 4: 1775V, 5-1: 1800, 5-2: 1800, 5-3: 1900, 5-4:1800, 6-2:1800, 7-2:1775, 8-3: 1800, 8-4:1875, 9-1: 1800, 9-4:1850

Run 136: Calo HV 4: 1825V, 5-1: 1850, 5-2: 1850, 5-3: 1950, 5-4:1850, 7-2:18255, 9-2: 1600, 9-4:1900

Run 137: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950

Run 138: Calo HV 5-3: 2000, 8-4: 1925, 9-4:1950

Run 139: changed SUM_THR =3 ( SUM_THR is threshold on the CALO trigger)

Run 140: changed SUM_THR =10

Run 141: changed individual calo thresholds from 40 to 80

Run 142: Calo HV 1:1750, 2:1825, 3:1800, 4:1875

Run 143: Add S2 plane to the VTP trigger ( before just calo), changed individual calo thresholds from 80 to 120

Run 144: same as 143

Run 145: same as 143

Run 146: same as 143

Run 147: same as 143

Run 148: changed individual calo thresholds from 120 to 150

Run 149: mistakenly changed calo thresholds 8-1,2,3,4 and 9-1,2,3,4 from 150 to 100

Run 150: changed time window from 768 to 200ns

Run 151: same as 150

Run 152: put calo thresholds 8-1,2,3,4 and 9-1,2,3,4 back to 150, set threshold for 1,2,3,4,5-1,-2,-3,-4 from 150 to 100

MODE 3 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)
Run 153: same as 152

Run 154: same as 152

Run 155: Calo HV 6-1: 1725V, 6-3: 1650V, 7-3: 1800V, 9-2: 1500V

Run 156: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V

Run 157: Calo HV 6-1: 1625V, 6-4: 1625V, 7-3: 1760V, 8-2: 1725V

Run 159: same as 157, steady 30uA on C-OPTICS

Run 161: 30uA on Pol-He3 cell. Use same scaler data as run 160.

MODE 1 Beam golden Runs - CO2; all detector channels ON - S2 + calo (after calorimeter gain matching)

Run 158: 30uA on multi-foil carbon target, Steve Wood took scaler rates before the run

Run 160: 30uA on PolHe3 target, took scaler rates before this run

Updated by Alexandre Camsonne about 5 years ago · 29 revisions