Activity
From 01/04/2024 to 02/02/2024
02/01/2024
- 10:28 AM Bug #929 (Closed): FADC channel with always same signal 952
- 10:15 AM Idea #904 (In Progress): Plotting the NPS Column Degradation vs Time
- 09:56 AM Bug #926 (New): HMS electron trigger efficiency
- 09:54 AM Bug #925 (In Progress): Scaler error
- 09:52 AM Task #920 (Resolved): Recalibration with block with x2 HV block 529
01/29/2024
- 10:50 AM Task #910 (In Progress): Add VTP paremeters to report file
- This was already done: https://github.com/JeffersonLab/nps_replay/pull/40
but the PR still has not been accepted. - 10:42 AM Bug #925 (Closed): Scaler error
- 10:38 AM Task #924 (In Progress): SIMC NPS simulation
- 10:28 AM Task #923 (Closed): Check HMS VDC calibration for latest data
- 10:15 AM Bug #922 (New): Some calorimeter blocks at different temperature in display
- Some calorimeter blocks at different temperature in display
Maybe issue with multiplexer - 10:13 AM NPS Calorimeter Task #834 (Closed): Calorimeter temperature checks
- 10:09 AM Task #871 (Closed): MIP analysis
- 10:06 AM Bug #921 (Closed): EDTM live time more than 100%
- 10:03 AM Task #902 (Closed): Coin_sparse/Coin_sparse_low Efficiency
- 09:58 AM NPS Calorimeter Bug #819 (Closed): Cable connector
- 09:53 AM Task #920: Recalibration with block with x2 HV block 529
- 19-17
- 09:53 AM Task #920 (Closed): Recalibration with block with x2 HV block 529
- 09:51 AM Task #908 (Closed): MIP calibration + Comparison MIP/e-p/Pi0 Calibration Methods
- 09:44 AM Task #909 (Closed): Clustering In The VTP and FADC Data Stream Description
- 09:44 AM Task #912 (Closed): PMT and base non linearity measurement
- 09:43 AM Task #913 (Closed): Include non linearity of base and PMT in HCANA
- 09:43 AM Task #911 (Closed): Pi0 calibration for different pi0 energies
01/22/2024
- 11:02 AM NPS DAQ Task #837: Deadtime studies
- Dead time estimation using two different ways. They are showing similar results.
Also available in: Atom