Run list » History » Version 23
Alexandre Camsonne, 01/02/2021 01:16 PM
| 1 | 1 | Alexandre Camsonne | h1. Run list |
|---|---|---|---|
| 2 | |||
| 3 | 500 |
||
| 4 | |||
| 5 | 501 DAQ crashed |
||
| 6 | |||
| 7 | 502 short run threshold check |
||
| 8 | 2 | Alexandre Camsonne | |
| 9 | 503 threshold check |
||
| 10 | 3 | Alexandre Camsonne | |
| 11 | 512 better threshold check 1500 V on scintillators |
||
| 12 | 4 | Alexandre Camsonne | |
| 13 | 513 long cosmics run |
||
| 14 | 5 | Alexandre Camsonne | |
| 15 | 15 | Jixie Zhang | 514 new run but bad thresholds no event, trigger was added into fadc channel 9 |
| 16 | 14 | Jixie Zhang | HV from channel 0-7 are: 1300, 1250,1000, 1000, 1050, 2050, 1850, 2000 |
| 17 | 5 | Alexandre Camsonne | |
| 18 | 515 run with new HV and thresholds |
||
| 19 | 14 | Jixie Zhang | HV from channel 0-7 are: 1300, 1250,1000, 1000, 1050, 2050, 1850, 2000 |
| 20 | 6 | David Flay | |
| 21 | 516 |
||
| 22 | 1 | Alexandre Camsonne | |
| 23 | 14 | Jixie Zhang | 517 increase HV for channel 1 and 7: |
| 24 | HV from channel 0-7 are: 1300, 1300,1000, 1000, 1050, 2050, 1850, 2050 |
||
| 25 | 6 | David Flay | |
| 26 | 518 Changed latency from 100 to 60. Ensuing decoded run showed an error: |
||
| 27 | 9 | David Flay | @ |
| 28 | Couldn't find block level ! |
||
| 29 | 1 | Alexandre Camsonne | ERROR getting FADC slot 7 block header |
| 30 | 9 | David Flay | ERROR fadc slot 7 event data length -1 <= 0 |
| 31 | @ |
||
| 32 | 6 | David Flay | |
| 33 | 519 Aborted. Reset latency to 100. |
||
| 34 | |||
| 35 | 10 | David Flay | 520 New run with latency set to 100. Stopped to check quality on decoding; looks good. |
| 36 | 1 | Alexandre Camsonne | |
| 37 | 14 | Jixie Zhang | |
| 38 | 1 | Alexandre Camsonne | 521 12-29-20 15:22 Tue New run started |
| 39 | 14 | Jixie Zhang | |
| 40 | 522 12-31-20 17:40, Jixie increased preshower HVs |
||
| 41 | HV from channel 0-7 are: 1300, 1300,1000, 1000, 1050, 2150, 1950, 2150 |
||
| 42 | 16 | Jixie Zhang | |
| 43 | 523 12-31-20 18:36, Jixie increased preshower3 HV to 2250 |
||
| 44 | HV from channel 0-7 are: 1300, 1300,1000, 1000, 1050, 2150, 1950, 2250 |
||
| 45 | 17 | Jixie Zhang | |
| 46 | 524 |
||
| 47 | |||
| 48 | 525 01-01-21 :connected preshowers to pre-amplifier, set HV as the following: |
||
| 49 | HV from channel 0-7 are: 1400, 1300,1000, 1000, 1050, 2050, 1850, 2050 |
||
| 50 | |||
| 51 | |||
| 52 | 526 01-01-21: lower HV of SC1 by 50V: |
||
| 53 | HV from channel 0-7 are: 1350, 1300,1000, 1000, 1050, 2050, 1850, 2050 |
||
| 54 | 18 | Jixie Zhang | |
| 55 | 19 | Jixie Zhang | 527 01-01-21 18:10 |
| 56 | |||
| 57 | 528 01-01-21 19:04 |
||
| 58 | 20 | Jixie Zhang | |
| 59 | 529 01-01-21 19:34 adjusted HV for ECal, and channel 7 |
||
| 60 | HV from channel 0-7 are: 1350, 1300,950 , 960, 1000, 2050, 1850, 2100 |
||
| 61 | 21 | Jixie Zhang | |
| 62 | 22 | Jixie Zhang | 530 01-01-21 20:50 adjusted HV for ECal, and channel 7 |
| 63 | 1 | Alexandre Camsonne | HV from channel 0-7 are: 1350, 1300, 920, 925, 980, 2050, 1850, 2080 |
| 64 | 22 | Jixie Zhang | |
| 65 | 531 01-01-21 23:42 |
||
| 66 | 23 | Alexandre Camsonne | |
| 67 | 532 01-02-21 13:16 change preshower range to 0.5 V ( x4 ) |