Actions
Analysis Tasks » History » Revision 165
« Previous |
Revision 165/174
(diff)
| Next »
Richard Trotta, 06/23/2022 03:57 PM
- Table of contents
- Analysis Tasks
- Ongoing
- On deck
- Replays
- FULL REPLAY 1 of data, with new calibrations Done
- FULL REPLAY 2 of data, Post-PionLT with updated scripts Done
- FULL REPLAY 3 of data, with improved optics and corrections Mid-August 2022
- FULL REPLAY 4 of data, with final calibrations and offsets Early January 2023
- FULL REPLAY 5 of data, with outstanding problems resolved Early April 2023
- FULL REPLAY 6 of data Early June 2023
- Completed
Analysis Tasks¶
Fall 2018/Spring 2019 Run | Completed |
Calibrations | Completed |
Efficiencies and offsets | Ongoing |
First iteration of cross section | On deck |
Fine tuning cross section iteration | To Do |
Form factor extraction | To Do |
This is a summary page with the progress of the KaonLT experiment. Above is a quick outline of our current progress. Below are tasks assigned to members of the group. Anyone who is part of the group may contribute to a task with suggestions and/or updates on progress. Please contact the assignee on a task-by-task basis for any queries. Anyone with general questions can contact Richard Trotta (trotta@cua.edu).
Ongoing¶
Complete by Early September 2022
Efficiencies Early August 2022¶
- Tracking Done
- Trigger Done
- PID
- CPU LT Done
- Electronic LT Done
- COIN time Done
- Missing Mass
Luminosity Early August 2022¶
- Richard, Ali
- LH2 boiling tests
- PID track studies
- PID calibration is good besides the HODO (need pionLT)
- Vijay has done some coin time studies which will be helpful
- Richard has analyzed most of the carbon data but need to update scripts with pionLT fixes to TLT and tracking
Elastics Early August 2022¶
- Richard, 10.6 data TODO
- Ali, 8.2/6.2 data TODO
- Vijay, 3.9/4.9 KaonLT data and 2.7/3.6/4.5 PionLT data Done
- singles
- Initial Heepcheck offset fitting to get corrected E, E', theta'.
- 3.9 GeV, 5 settings Done
- 4.9 GeV, 4 settings Done
- 2.7 GeV, 3 settings Done
- Overall this study looks ok. At the moment, I've not applied the various corrections to the normalized yield.
- coin
- Initial Heepcheck offset fitting to get corrected E, E', theta'.
- 3.9 GeV Done
- 4.9 GeV Done
- 2.7 GeV TODO
- 3.6 GeV Done
- 4.5 GeV TODO
- Overall this study looks ok (better than singles). At the moment, I've not applied the various corrections to the normalized yield.
Heepcheck offsets Early October 2022¶
- Richard/Ali/Vijay
- Check that Heepcheck offsets produce consistent p(e,e'K+)L, p(e,e'pi+)n p(e,e'p)omega missing masses.
Check stability of cointime peak ???¶
- Vijay
- A previous study has been done by Vijay, need more info
- In Fpi-2 it drifted with TDC temperature and needed to be adjusted on a run-by-run basis to within 200 ps.
- Initial checks so far indicate the peak is stable. Cointime resolution will be poorer in fall 2018 run due to DAQ cabling issue. Mark has partial software fix that we need to be sure is implemented.
SHMS and HMS Optics Improvements ???¶
- Mark Jones
- SHMS
- HMS, unsure
On deck¶
Complete by Early January 2023
Initial ep elastic cross-section checks Early December 2022¶
- Richard/Ali/Vijay
- Singles cross-sections, HMS and SHMS. SHMS delta scans (only peak position checked so far, stability of normalized yield ratio not yet checked). Coin ep cross-sections.
- In Fpi-2, determing the correct proton absorption correction for normalized required some literature review and other digging.
Replays¶
FULL REPLAY 1 of data, with new calibrations Done¶
- This replay should include all new kinematic offsets, better timing and PID calibrations, as well as Mark's most recent HMS and SHMS matrix elements.
- Quality control rechecks with new replay:
- carbon luminosity scans are flat vs. current and rate
- LH2 luminosity scans are flat vs. current and rate
- HMS saturation corrections?
- Final investigation of SHMS acceptance, optimize acceptance cuts based on sieve-slit run analysis, agreement with single-arm MC.
- Compare data and simulation plots of SHMS yfp,ypfp for various ytar,delta bins to identify inconsistencies.
- Trigger blocking studies.
- Are extra factors needed to correct for missing FADC reference times, or any other DAQ related effects? Initial info from Peter Bosted indicates this is likely to be the case.
- Recheck Heep singles and coin yields to identify and fix problems.
- Stability checks. Need some scripts to look at invariant mass vs run number, etc., for pi+/K+/p channels.
FULL REPLAY 2 of data, Post-PionLT with updated scripts Done¶
- This replay should include all new kinematic offsets, better timing and PID calibrations, as well as Mark's most recent HMS and SHMS matrix elements.
- HMS saturation corrections?
- Compare data and simulation plots of SHMS yfp,ypfp for various ytar,delta bins to identify inconsistencies.
- Trigger blocking studies.
- Are extra factors needed to correct for missing FADC reference times, or any other DAQ related effects? Initial info from Peter Bosted indicates this is likely to be the case.
- Recheck Heep singles and coin yields to identify and fix problems.
- Stability checks. Need some scripts to look at invariant mass vs run number, etc., for pi+/K+/p channels.
FULL REPLAY 3 of data, with improved optics and corrections Mid-August 2022¶
- SECOND LEVEL ANALYSIS TASKS with REPLAY 3 ntuples:
- Quality control rechecks with new replay:
- carbon luminosity scans are flat vs. current and rate
- LH2 luminosity scans are flat vs. current and rate
- Final investigation of SHMS acceptance, optimize acceptance cuts based on sieve-slit run analysis, agreement with single-arm MC.
- Final SHMS optic matrix element and acceptance determination.
- Final HMS optics check.
- Final Heepcheck offsets.
- Better detector efficiency determination.
- First check of Bill's L/T separation code.
- Quality control rechecks with new replay:
FULL REPLAY 4 of data, with final calibrations and offsets Early January 2023¶
- THIRD LEVEL ANALYSIS TASKS with REPLAY 4 ntuples:
- Final ep elastic cross-section checks.
- Look at data in depth, and resolve outstanding problems.
- First SIMC ntuple generation using new offsets.
- Detailed Data/SIMC comparisons for HMS and SHMS focal plane and target reconstructed quantities, as well as W, Q^2, t, phi.
- Preliminary L/T separation results.
FULL REPLAY 5 of data, with outstanding problems resolved Early April 2023¶
- ADVANCED ANALYSIS TASKS with REPLAY 5 ntuples:
- Final SIMC ntuple generation using final parameters.
- Thorough look at L/T/LT/TT separations, consistency checks as necessary.
- Final look at systematic error contributions.
FULL REPLAY 6 of data Early June 2023¶
- Hopefully not necessary
- OBTAIN:
- Separated cross-section results.
- Form factor determination begins. Model systematic error tests. Use more than one model, if at all possible.
- Model dependence and other issues in form factor extraction.
Begin thesis writing, drafts of first papers
Completed¶
BCM calibrations Done¶
- Fall 2018-Spring 2019
- BCM1,2 are stable, have a small nonlinearity >60uA that remains to be
calibrated - Final BCM for fall and spring
- BCM1,2 are stable, have a small nonlinearity >60uA that remains to be
- Summer 2019
- BCM1,2 both okay, including small nonlinearity corr.
Beam Energy calibrations Done¶
- Mark Jones
- This page incorporates May/2019 problem fix that caused to give wrong
beam energies
- This page incorporates May/2019 problem fix that caused to give wrong
Python analysis scripts Done¶
Timing windows and reference times Done¶
- Richard/Stephen
- This was completed for hodoscopes, drift chambers by Richard/Stephen. Every HMS/SHMS channel needs to be re-done for the new hcana code.
RF time for SHMS PID Done¶
- Stephen
- 1-Apr-2020 Update
- Still need to set RF gates for each particle type, apply TOF corrections for particles other than pion,
check offsets for other settings.
- Still need to set RF gates for each particle type, apply TOF corrections for particles other than pion,
Calibrations Done¶
- Calorimeter
- Hamlet/Richard/Hakob/Stephen/Vladimir/Vardan
- HMS+SHMS
- Bill Henry's 9-Jan-2020 report on calib algorithm improvements
- Aerogel
- Vladimir/Richard
- Redmine lists calibration completed by Vladimir. Need a link to the report. Cuts, PID analysis, efficiencies, not yet done.
- HGCer
- Garth/Vijay
- New calibrations almost done. Report in progress. A position dependent efficiency for pi+ and K+ will have to be implemented. This is not yet started.
- HMS+SHMS DC
- Stephen/Richard
- HMS+SHMS
- Hodoscope
- Vijay/Ali
- The second band is alright to keep for now until we tighten our time windows. Then the calibrations will need to be redone. This will not be until efficiencies are well established.
SHMS tracking algorithm optimization and efficiencies Done¶
EDTM Done¶
- Richard
- Jacob and Richard have looked into this with various log entries..
- Dave Mack Studies
Updated by Richard Trotta over 2 years ago · 165 revisions